HomeMy WebLinkAboutE202 - Level 2 Electrical PlansI.T. ROOM I.T. ROOM EV (R.I.) FOR TWO (2) SPACES, TYPICAL EV (R.I.) FOR TWO (2) SPACES, TYPICAL EV (R.I.) FOR TWO (2) SPACES, TYPICAL UP DN EMERGENCY CALL BUTTON EV (R.I.) FOR TWO (2) SPACES, TYPICAL RAMPDOWNRAMPUPH H 1 2 32.61.3 A C D E F G H I J L B K 2.5 J J 1 2 32.61.3 A C D E F G H I J L B K 2.5 OSOS (2) 2"C FOR DATA LV-OP1#7 LV-OP1#7 LV-OP1#5 LV-OP1#5 LV-OP1#15 LV-OP1#17 CU-5 CU-6 01 01 02 HV-OP1#7 03 LV-EM1#2 DS-6 DS-2 DS-5 EF-2 EF-3 HV-OP1#18,20,22 HV-OP1#21,23,25 PG1PG1PG1 PG1 PG1PG1 PG1 PG1 PG1 PG1 PG1 PG1PG1PG1PG1 PG1 PG1 PG1 PG1 PG1PG1PG1PG1 PG1 PG1 PG1 PG1 PG1PG1PG1PG1 PG1 PG1 PG1 PG1 PG1PG1PG1PG1PG1 PG1 PG1 PG1 PG1 PG1 D1 D1 D1 D1 L1 L1 L3 L3 L3L3 L3 L3 L3 L3 L1 L1 EM-1 EM-1 EM-1 HV-EM1#9 HV-EM1#4 HV-OP1#4 HV-OP1#4 SHEET NO. DATE SCALE CHECKED BY DRAWN BY CERTIFIED BY CIVIC SQUARE PARKING GARAGE50 Red Truck Rd, Carmel, IN 46032TITLE1/16" = 1'-0"10/25/2021 11:31:48 AMLEVEL 2 ELECTRICALPLANSJLS JLS 10/25/2021 E202 1/16" = 1'-0"1 LEVEL 2 POWER PLAN 1/16" = 1'-0"2 LEVEL 2 LIGHTING PLAN E202 - KEYED NOTES 01 02 DUCTLESS SPLIT SYSTEM FOR ELEVATOR VESTIBULE. 03 BLADE SIGN FEED CONTROLLED BY TIME CLOCK. 04 EMERGENCY CIRCUITS ARE NOT TO BE COMBINED WITH GENERAL LIGHTING CIRCUITS PER NEC 700. 05 GARAGE LIGHTING TO REMAIN POWERED AT ALL TIME. POWER - GENERAL NOTES A INITIATING CIRCUITS SHALL BE 18/2 AWG TWISTED PAIR FPL CABLE, AND FPLP CABLE WHERE OPEN PLENUM RETURN IS USED. B NAC CIRCUITS SHALL BE 12/2 AWG FPL CABLE, AND FPLP CABLE WHERE OPEN PLENUM RETURN IS USED. LIGHTING - GENERAL NOTES A REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT PLACEMENT OF ALL LIGHTING FIXTURES. VERIFY CEILING CONSTRUCTION AND PROVIDE LIGHTING FIXTURES WITH ALL NECESSARY MOUNTING HARDWARE. B RECESSED FIXTURES SHALL BE PROVIDED WITH STRUCTURAL SUPPORTS, AS REQUIRED BY THE AHJ. IF REQUIRED, REFER TO DETAIL SHEETS FOR INSTALLATION REQUIREMENTS. C RECESSED FIXTURES LOCATED IN A FIRE RATED CEILING SHALL BE PROVIDED WITH A FIVE SIDED ENCLOSURE, WITH A FIRE RATING GREATER THAN OR EQUAL TO THE RATING OF THE CEILING ASSEMBLY. THE ENCLOSURE SHALL MEET ALL NEC AND MANUFACTURER REQUIRED CLEARANCES. D ALL WORK SHALL BE INSTALLED PARALLEL AND PERPENDICULAR TO THE BUILDING STRUCTURE, WHERE EXPOSED. ALL EXPOSED WIRING SHALL BE IN CONDUIT, UNLESS OTHERWISE APPROVED BY OWNER. E ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROPERLY SEALED WITH AN APPROVED FIRE STOP SYSTEM GREATER THAN OR EQUAL TO THE FIRE RATING OF THE WALL ASSEMBLY. F RACEWAYS SHALL NOT BE PERMITTED TO SERVE AS AN EGC. G ALL EXTERIOR PENETRATIONS, AND / OR PENETRATIONS THROUGH A THERMAL ENVELOPE, SHALL BE SEALED WITH AN APPROVED SEALANT TO PREVENT THE ENTRANCE OF AIR OR WATER. (NEC ART. 300.7(A)) H EMERGENCY LIGHTING WITH INDIVIDUAL BATTERY BACKUP SHALL BE FED FROM THE SAME CIRCUIT AS THE LIGHTING IN THE AREA WHICH IT SERVES. (NEC ART. 700.12(F)) 04 05 No. Description Date 1 ISSUE FOR PERMIT 10/25/ 2021