HomeMy WebLinkAboutE701 - DetailsSH TS FS TS FS TS H H H H H S TS TS TS EOLR 1ST FLOOR ELEVATOR LOBBY 2ND FLOOR ELEVATOR LOBBY 3RD FLOOR ELEVATOR LOBBY 4TH FLOOR ELEVATOR LOBBY FIRE ALARM CONTROL PANEL (FACP) 120V BY E.C. 1ST FLOOR LOBBY W.P. @FACP SPRINKLER RISERS STAIRWELL RISERS A B C N 20' MIN. CONCRETE ENCASED REBAR NEC 250.52(A)(3) F 10' MIN (2) 5/8"x8' GROUND RODS, 24" MIN FROM EDGE OF BUILDING NEC 250.52(A)(5) #4 AWG CU C #1/0 AWG CU METAL WATER PIPING NEC 250.52(A)(1) NEC 250.104(A) F H G SOURCE TRANSFORMER MAIN BONDING JUMPER / SCREW. DETAIL NOTES A NON-CURRENT CARRYING METAL EQUIPMENT CONTAINING SERVICE CONDUCTORS SHALL BE BONDED TOGETHER. WHERE POSSIBLE, USE SCH. 40 PVC OR SCH. 80 PVC. (NEC 250.80, 250.92, 250.102) B GROUNDING ELECTRODE CONDUCTOR. (NEC 250.66)C CONNECTIONS SHALL BE MADE USING LISTED CONNECTORS, AND GRADE 2 HARDWARE WITH CORROSION RESISTANT COATING. REMOVE PAINT AND OTHER NON-CONDUCTIVE COATINGS FROM GROUNDING ELECTRODES PRIOR TO MAKING CONNECTIONS. E FERROUS METAL RACEWAYS AND ENCLOSURES CONTAINING GROUNDING ELECTRODE CONDUCTORS SHALL BE BONDED TO THE GROUNDING ELECTRODE. (NEC 250.64(E)) F PROVIDE BONDING JUMPERS AROUND WATER METERS, FILTERS, HEAT TRAPS, AND SIMILAR DEVICES. (NEC 250.53(D)(1)) (NEC 250.104) G BOND METAL WATER PIPING TO EITHER STRUCTURAL STEEL OR SERVICE ENTRANCE GROUNDED CONDUCTOR BUS. (NEC 250.104) H #1/0 AWG CU G MAIN A B C METER B A N (TYP) STRUCTURAL STEEL NEC 250.52(A)(2) F ADDITIONAL SERVICE DISCONNECTING MEANS AND SEPARATELY DERIVED SYSTEMS SHALL BE BONDED TO BUILDING STEEL, OR TO A COMMON GROUNDING ELECTRODE CONDUCTOR. D N SHEET NO. DATE SCALE CHECKED BY DRAWN BY CERTIFIED BY CIVIC SQUARE PARKING GARAGE50 Red Truck Rd, Carmel, IN 46032TITLEAs indicated 10/25/2021 11:31:55 AMDETAILSJLS JLS 10/25/2021 E701 NTS2FIRE ALARM RISER DIAGRAM FIRE ALARM - KEYED NOTES 01 RATE OF RISE HEAT DETECTOR AT TOP OF ELEVATOR SHAFT. 02 RATE OF RISE HEAT DETECTOR LOCATED IN ELEVATOR LOBBY. 03 POST INDICATOR VALVE (PIV). PROVIDE TAMPER SWITCH AT THE VALVE FOR A SUPERVISORY SIGNAL TO THE FACP. 04 PROVIDE HORN STROBE IN A WEATHER PROOF ENCLOSURE. 05 FIRE ALARM CONTROL PANEL. PROOVIDE DEDICATED 120VOLT CIRCUIT AND CONNECT AS DIRECTED. THE FIRE ALARM PANEL IS TO BE PROVIDED WITH INPUT AND OUTPUT CONTACTS TO ALLOW CONNECTION TO FUTURE RETAIL AND RESIDENTIAL SYSTEMS. 06 FIRE ALARM ANNUNCIATOR PANEL. 01 02 03 04 05 06 FIRE ALARM - GENERAL NOTES A INITIATING CIRCUITS SHALL BE 18/2 AWG TWISTED PAIR FPL CABLE, AND FPLP CABLE WHERE OPEN PLENUM RETURN IS USED. B NAC CIRCUITS SHALL BE 12/2 AWG FPL CABLE, AND FPLP CABLE WHERE OPEN PLENUM RETURN IS USED. NTS1SERVICE GROUNDING DETAILS - PANELBOARDS No. Description Date 1 ISSUE FOR PERMIT 10/25/ 2021