Loading...
HomeMy WebLinkAboutP100 - Foundation and First Floor Plumbing PlanLONG-TERM BYCYCLE PARKING (MINIMUM 48 BIKES) WALL MOUNT ELECT. TRASH CARMEL STREET DEPT AND STORAGE -1'-6" AFF CONDO ACCESS ELEC. DOG WASH PUBLIC PARKING ENTRY STOR.RISER BIKE STACK RACK RAMP UP GEN. DATA RAMP DOWN UP STOR. NO PARKING NO PARKING NO PARKING RAMP UP RAMP UP CROSS WALK STOP1 2 32.61.3 A C D E F G H I J L B K RAMPUP2.5 MD ELECT. ELEC. DOG WASH PUBLIC PARKING ENTRY STOR.RISER BIKE STACK RACK RAMP UP GEN. DATA RAMP DOWN STOR. RAMP UP RAMP UP CROSS WALK STOPRAMPUP6 P500 3/4" CW 3/4" CW 3/4" CWHB-1 4" FD-1 4" FD-1 4" FD-1 INT-1 9 8 9 8 9 8 9 8 4" FD-1 3/4" CW 10 10 HB-1 11 11 11 P100 3 10" ST 8" ST 10" ST 8" ST 10" ST 8" SAN 8" ST 4" SAN 4" V 4" SAN 10" ST 8" ST 8" ST 12 3 1 1 12 INT-1 4 F.F.E. = 837.35' 12" ST 4" SAN 4" SAN 4" SAN 4" SAN 3 4" SAN 4" SAN 4" SAN 5 4" SAN 4" SAN 4" SAN 4" SAN 4" SAN 4" SAN 3 2 4"SAN I.E. = -7' -7" (829.72') 6 7 4" SAN 4" SAN 8" ST 3 4" SAN 12"ST I.E.=-5' -4" (832.00') 2 3/4" CW 3/4" CW 6" CW 4" SAN (BY OTHERS) 12 13 GENERAL NOTES: 1. PROVIDE NEW DOMESTIC WATER, SANITARY WASTE, STORM DRAINAGE AND NATURAL GAS SYSTEMS FOR THIS BUILDING. PROVIDE ALL NECESSARY COMPONENTS FOR FULLY OPERATIONAL SYSTEM. INSTALL SYSTEMS IN ACCORDANCE WITH STATE REQUIREMENTS AND LOCAL AUTHORITY HAVING JURISDICTION. COORDINATE THE LOCATION OF ALL UTILITY CONNECTION POINTS, FLOOR DRAINS AND HUB DRAINS FOR EQUIPMENT WITH OTHER TRADES. 2. ALL FLOOR PENETRATIONS TO BE SEALED WATER TIGHT BY TRADE CONTRACTORS. 3. ALL PENETRATIONS THROUGH FIRE RESISTANCE RATED CONSTRUCTION SHALL BE PROVIDED A UL LISTED THROUGH PENETRATION FIRESTOP ASSEMBLY. THE RATINGS OF ALL FIRESTOP ASSEMBLIES SHALL BE GREATER THAN OR EQUAL TO THE RATING OF THE PENETRATED BARRIER. 4. CORE DRILL PENETRATIONS IN CONCRETE FLOORS OR WALLS 1-2 INCHES LARGER THAN THE PIPE DRIAMETER OF THE PENETRATING PIPE. 5. NO STURCTURAL MEMBERS SHALL BE CUT, DRILLED OR BURNED WITHOUT THE KNOWLEDGE AND WRITTEN APPROVAL OF OWNER. 6. MAINTAIN MAIXIMUM HEADROOM AT ALL LOCATIONS. ALL PIPING TO BE AS TIGHT TO THE UNDERSIDE OF DECK AS POSSIBLE. ALL EXPOSED PIPING SHALL BE APPROVED BY ARCHITECT AND SHALL MAINTAIN REQUIRED CLEARANCES. 7. STORM AND SANITARY PIPING ARE TO BE INSTALLED SLOPED AT CODE ALLOWABLE SLOPES. 3/4" CW 3/4" CW EWH-1 3/4" HW 3/4" CW 15 16 18 17 DOG WASH -RD PE11400027 NENOISS AL EFORP D STATE OF NI I A N A ERGIN ESIGE T E RE No.CAMERO NT .YAMA SHITASHEET NO. DATE SCALE CHECKED BY DRAWN BY REVISIONSYM.DATE CERTIFIED BY CIVIC SQUARE PARKING GARAGE50 Red Truck Rd, Carmel, IN 46032TITLEAs indicated 10/25/2021 10:14:51 AMFOUNDATION AND FIRSTFLOOR PLUMBING PLANC.Y. D.T. 10/25/21 P100 1/16" = 1'-0"P100 1 FIRST FLOOR PLUMBING PLAN 1/16" = 1'-0"P100 2 FOUNDATION PLUMBING PLAN # PLAN NOTES 1 6" STORM UP. 2 4" SANITARY STACK UP. 3 4" SANITARY UP TO FLOOR DRAIN. 4 12" STORM CONNECT TO STORM STRUCTURE IN GARAGE. 5 4" SANITARY UP TO FLOOR CLEANOUT. 6 SEE CIVIL ENGINEER'S SITE UTILITY PLAN FOR CONTINUATION. 7 4" VENT UP TO ABOVE THIRD FLOOR. 8 6" STORM CONDUCTOR. 9 4" SANITARY STACK . 10 3/4" COLD WATER RISER WITH HOSE BIBB AT 24" A.F.F. EACH FLOOR. RISER INSTALLED TO BE ABLE TO DRAIN DOWN THROUGH LOWEST HOSE BIBB. 11 3/4" COLD WATER. INSTALL SLOPED FROM CENTER TO EACH HOSE BIBB RISER FOR DRAIN DOWN. 12 3/4" PEX COLD WATER UP THROUGH SLAB IN DOG WASH ROOM. TRANSITION TO COPPER ABOVE SLAB. 13 3/4" PEX COLD WATER UP THROUGH SLAB IN RISER ROOM. TRANSITION TO COPPER ABOVE SLAB. 15 3/4" COLD WATER UP TO CEILING. CONNECT TO HOSE BIBB SUPPLY, WATER HEATER SUPPLY AND DOWN TO DOG WASH, 16 1/2" HOT AND COLD WATER DOWN TO DOG WASH MIXING FAUCET. DOG WASH AND FAUCET BY OTHERS. 17 3/4" COLD WATER TO HOSE BIBB RISERS. PROVIDE ISOLATION VALVE IN DOG WASH FOR WINTER SHUT-DOWN. 18 WATER HEATER ON SHELF MOUNTED HIGH ON WALL. 1/4" = 1'-0"P100 3 ENLARGED DOG WASH ROOM PLUMBING PLAN