Loading...
HomeMy WebLinkAboutP500 - Plumbing Schedules and DetailsSPREADER TO BE USED ON PIPE SIZES 10" AND ABOVE SPREADER TO BE USED ON PIPE SIZES 10" AND ABOVE STANDARD PIPE COVERING SHIELD NON-INSULATED PIPES (BELOW 4") INSULATED PIPES (COLD) (4" AND ABOVE) INSULATED PIPES (HOT & COLD) (BELOW 4") NON-INSULATED PIPES (COLD) (4" AND ABOVE) SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ROOF CONSTRUCTION AND FLASHING DETAILS. NOTES: 1. PRE-MOLDED PIPE SEAL MUST HAVE INTACT RIB AT TOP EDGE, REGARDLESS OF PIPE DIAMETER 2. APPLY IN -SEAM SEALANT 1/2" FROM INSIDE EDGE OF PIPE SEAL FLANGE. WATER CUT -OFF MASTIC -07 54 33 IN -SEAM SEALANT WATER CUT -OFF MASTIC -07 54 33 LAP SEALANT 07 54 32 STAINLESS STEEL CLAMPING RING PREMOLDED PIPE SEAL 1/4" COVER BD. 07 22 16.01 LAP SEALANT, 07 54 32 FLOOR DRAIN STRAINER FINISHED FLOOR DRAIN BODY POURED IN PLACE GASKET CONCRETE PIPE HANGERS AND SUPPORTS PIPE SIZE MAX. HANGER SIZE HANGAR ROD DIAMETER 1/2" TO 1 1/2"6'-0"3/8" 2"10'-0"3/8" 2 1/2" TO 3"10'-0"1/2" 4" TO 6"10'-0"5/8" 8" TO 12"12'-0"7/8" 14" AND OVER 12'-0"1" PVC (ALL SIZES)PER MFR'S RECOMMENDATION AND INDIANA CODE MATERIALS LIST: 1.DRAIN, WASTE AND VENT ABOVE AND BELOW GRADE: A.SCHEDULE 40 PVC PIPE AND FITTINGS WITH SOLVENT JOINTS. ALL SANITARY WASTE AND VENT VERTICAL RISERS SHALL BE PVC NO HUB PIPING WITH THE PIPE MANUFACTURERS HEAVY DUTY COUPLINGS. 2.COLD WATER BELOW GRADE: A.DOMESTIC WATER PIPING FROM 5'-0" OUTSIDE OF BUILDING FOUNDATION TO A POINT 12" ABOVE THE MECHANICAL ROOM FLOOR SHALL BE DUCTILE IRON PIPE AND FITTINGS FOR TYPE C-900 POLYVINYL CHLORIDE PIPE AND FITTINGS. COLD WATER BRANCH PIPING BELOW SLAB TO BE SINGLE RUN PEX. ABOVE GRADE HOT AND COLD WATER PIPING: A.ALL DOMESTIC HOT AND COLD WATER PIPING TO BE TYPE "L" COPPER TUBING, HARD EMPER, COLD DRAWN WITH WROUGHT COPPER LEAD FREE SWEAT FITTINGS. ALL COPPER WATER PIPING ABOVE GRADE SHALL BE PROVIDED WITH 1/2" INSULATION LIKE ARMAFLEX, RUBATEX OR FIBERGLASS. 3.STORM PIPING ABOVE AND BELOW GRADE: A.ALL STORM WATER PIPING SHALL BE SCHEDULE 40 PVC WITH SOLVENT JOINTS. HORIZONTAL STORM PIPING TO BE PROVIDED WITH 1/2" INSULATION LIKE ARMAFLEX OR RUBATEX OR FIBERGLASS. Level 1 100' -0" Level 2 111' -4" Level 1 100'-0" Level 2 111'-4" A 3/4" CW RPZ-1 WATER METER (BY UTILITY) FLOOR DRAIN 4" SAN 6" CW (BY OTHERS) 6" CW CAPPED FOR FUTURE CONNECTION 6" SHUT-OFF VALVE GARAGE WATER SERVICE SHUT-OFF VALVE 3/4" CW BELOW SLAB TO DOG WASH ROOM FUNNEL DRAIN WITH AIR GAP 4" V 4" SAN 4" SAN 4" SAN 8" ST 6" ST 4" SAN 4"FD-1 4" SAN 4" SAN 4"FD-1 6"AD-1 6"AD-1 6"AD-1 6"AD-1 4" SAN 8" ST 12" ST 10" ST 4" SAN 6" ST4" SAN 4" SAN 4" SAN 8" ST 6" ST 4" SAN 4" SAN 4" SAN 4" SAN 4" SAN 4" SAN 4" SAN 8" ST 4" SAN 4" SAN 6" ST 4"FD-1 4"FD-1 4"FD-1 4"FD-1 FCO4" SAN 4"FD-1 8" ST 4" SAN 10" ST 8" SAN INT-1 4"FD-1 FCO RD PE11400027 NENOISS AL EFORP D STATE OF NI I A N A ERGIN ESIGE T E RE No.CAMERO NT .YAMA SHITASHEET NO. DATE SCALE CHECKED BY DRAWN BY REVISIONSYM.DATE CERTIFIED BY CIVIC SQUARE PARKING GARAGE50 Red Truck Rd, Carmel, IN 46032TITLEAs indicated 10/25/2021 10:14:52 AMPLUMBING SCHEDULESAND DETAILSC.Y. D.T. 10/25/21 P500 SCALE: NTS1PIPE HANGER DETAIL SCALE: NTS2VENT THRU ROOF DETAIL SCALE: NTS3FLOOR DRAIN DETAIL SCALE: NTS6WATER SERVICE ENTRANCE SCALE: SANITARY AND VENT ISOMETRIC FLOOR DRAIN AND MISCELLANEOUS SCHEDULE MARK MANUFACTURER MODEL NUMBER DESCRIPTION REMARKS AD-1 SIOUX CHIEF 832-49DF FINISHLINE ADJUSTABLE, DUCTILE IRON, HIGH CAPACITY DRAIN, CORING PLUG AND ROUND CAST IRON TRAFFIC RATED STRAINER WITH DEBRIS BASKET. ADJUSTABLE BEFORE AND AFTER THE POUR, SIZE AS SHOWN ON DRAWINGS, SLOPE TO FLOOR DRAIN FCO-1 SIOUX CHIEF 832-4AF/832-4HNR FINISHLINE ADJUSTABLE CLEANOUT WITH ROUND NICKEL BRONZE TOP ADJUSTABLE BEFORE AND AFTER THE POUR, SIZE AS SHOWN ON DRAWINGS, SLOPE TO FLOOR DRAIN FD-1 SIOUX CHIEF 832-36PF FINISHLINE ADJUSTABLE, PVC, CORING PLUG AND ROUND NICKEL BRONZE TOP ADJUSTABLE BEFORE AND AFTER THE POUR, SIZE AS SHOWN ON DRAWINGS, SLOPE TO FLOOR DRAIN INT-1 STRIEM 0S-75 75 GPM, POLYETHYLENE TANK, 110 GALLON CAPACITY PROVIDE EXTENSION RING WITH TRAFFIC RATED COVER PLUMBING EQUIPMENT SCHEDULE MARK MANUFACTURER MODEL NUMBER LOCATION CAPACITY (GALLONS) RECOVERY (GAL/HR) TEMPERATURE RISE (DEG F°)DESCRIPTION ELECTRICAL DATA KW VOLTS PHASE DWM-1 (BY UTILITY) (BY UTILITY) WATER SERVICE ROOM DOMESTIC WATER METER - BY UTILITY - - - EWH-1 STATE PCE40 S0LSA DOG WASH 40 20 90 40 GALLON SHORT MODEL ELECTRIC WATER HEATER, 4.5KW, 120V. SHELF MOUNTED ON WALL, 120 DEGREE SET POINT 4.5 120 1 RPZ-1 WILKINS 975XL - 3/4" WATER SERVICE ROOM - - - 3/4" LOW LEAD BRONZE BODY RPZ; 30 GPM AT 14 PSI DROP - - - PLUMBING FIXTURE SCHEDULE MARK FIXTURE STYLE FIXTURE TRIM PIPE SIZES FIXTURE UNIT REMARKS NOTESMANUFACTURER MODEL NUMBER MANUFACTURER MODEL NUMBER WASTE VENT CW HW DFU WFU HB-1 HOSE BIBB WALL MOUNTED WOODFORD 24 - - - - 1/2" - - 1.0 SURFACE MOUNT AT LOCATIONS AND ELEVATIONS PER DRAWINGS.