Loading...
HomeMy WebLinkAboutE201 - Level 1 Electrical PlansLONG-TERM BYCYCLE PARKING (MINIMUM 48 BIKES) WALL MOUNT ELECT. TRASH CARMEL STREET DEPT AND STORAGE -1'-6" AFF CONDO ACCESS ELEC. DOG WASH PUBLIC PARKING ENTRY RESIDENTIAL PARKING ENTRY STOR.RISER BIKE STACK RACK EV (R.I.) FOR TWO (2) SPACES, TYPICAL EV (R.I.) FOR TWO (2) SPACES, TYPICAL EV (R.I.) FOR TWO (2) SPACES, TYPICAL DATA RAMP DOWN UP STOR. EV (R.I.) FOR TWO (2) SPACES, TYPICAL EV (R.I.) FOR TWO (2) SPACES, TYPICAL EMERGENCY CALL BUTTON NO PARKING NO PARKING NO PARKING RAMP UP RAMP UP CROSS WALK H H V H H RRRRRRRRRRRRAMPUPV 26 27 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 STOPDuke 1 2 32.61.3 A C D E F G H I J L B K 2.5 FAA STOPDuke 1 2 32.61.3 A C D E F G H I J L B K 2.5 J J J OSOSOS OS OS LV-OP1#2,4,6 01 LV-EM1 T-EM1 HV-EM1 ATS-EM1 ATS-OP1 HV-OP1 HV-2B HV-2A HV1 T-OP1 E401 1 E401 2 E401 3 E401 4 04 03 05 07 E401 5 LV-OP1 LV-EM1#5 (2) 2" CONDUIT TO LEVEL 2 MDF ROOM LV-EM1#6 LV-EM1#7 EF-5 EF-4 HV-OP1#24,26,28 L1 L1 L4 L4 L4L4L4 L4 L4 L4 L4 L4 L4 L4L4L4 L4 L4 L4 L4L4L4 L1 L1 D1 D1 D1 D1 PG1 PG1 PG1 PG1 PG1 PG1PG1 PG1 PG1 PG1 PG1 PG1 PG1 PG1 PG1 PG1 PG1 PG1 PG1 PG1 PG1 PG1PG1 PG1 PG1 PG1PG1PG1 PG1 PG1PG1 PG1PG1PG1 PG1 PG1 PG1 PG1 PG1 PG1 L3 L3 (2) PG1 PG1 EM-1 EM-1 EM-1 EM-1 EM-1EM-1 L2 L2 L2 L2 L3 L3 L3 L3 L3 L3 L3 L3 L3 06 08 HV-EM1#2 HV-OP1#2 HV-EM1#7 SHEET NO. DATE SCALE CHECKED BY DRAWN BY CERTIFIED BY CIVIC SQUARE PARKING GARAGE50 Red Truck Rd, Carmel, IN 46032TITLE1/16" = 1'-0"10/25/2021 11:31:46 AMLEVEL 1 ELECTRICALPLANSJLS JLS 10/25/2021 E201 1/16" = 1'-0"1 LEVEL 1 POWER PLAN 1/16" = 1'-0"2 LEVEL 1 LIGHTING PLAN POWER - GENERAL NOTES A INITIATING CIRCUITS SHALL BE 18/2 AWG TWISTED PAIR FPL CABLE, AND FPLP CABLE WHERE OPEN PLENUM RETURN IS USED. B NAC CIRCUITS SHALL BE 12/2 AWG FPL CABLE, AND FPLP CABLE WHERE OPEN PLENUM RETURN IS USED. LIGHTING - GENERAL NOTES A REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT PLACEMENT OF ALL LIGHTING FIXTURES. VERIFY CEILING CONSTRUCTION AND PROVIDE LIGHTING FIXTURES WITH ALL NECESSARY MOUNTING HARDWARE. B RECESSED FIXTURES SHALL BE PROVIDED WITH STRUCTURAL SUPPORTS, AS REQUIRED BY THE AHJ. IF REQUIRED, REFER TO DETAIL SHEETS FOR INSTALLATION REQUIREMENTS. C RECESSED FIXTURES LOCATED IN A FIRE RATED CEILING SHALL BE PROVIDED WITH A FIVE SIDED ENCLOSURE, WITH A FIRE RATING GREATER THAN OR EQUAL TO THE RATING OF THE CEILING ASSEMBLY. THE ENCLOSURE SHALL MEET ALL NEC AND MANUFACTURER REQUIRED CLEARANCES. D ALL WORK SHALL BE INSTALLED PARALLEL AND PERPENDICULAR TO THE BUILDING STRUCTURE, WHERE EXPOSED. ALL EXPOSED WIRING SHALL BE IN CONDUIT, UNLESS OTHERWISE APPROVED BY OWNER. E ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROPERLY SEALED WITH AN APPROVED FIRE STOP SYSTEM GREATER THAN OR EQUAL TO THE FIRE RATING OF THE WALL ASSEMBLY. F RACEWAYS SHALL NOT BE PERMITTED TO SERVE AS AN EGC. G ALL EXTERIOR PENETRATIONS, AND / OR PENETRATIONS THROUGH A THERMAL ENVELOPE, SHALL BE SEALED WITH AN APPROVED SEALANT TO PREVENT THE ENTRANCE OF AIR OR WATER. (NEC ART. 300.7(A)) H EMERGENCY LIGHTING WITH INDIVIDUAL BATTERY BACKUP SHALL BE FED FROM THE SAME CIRCUIT AS THE LIGHTING IN THE AREA WHICH IT SERVES. (NEC ART. 700.12(F)) E201 - KEYED NOTES 01 INSTALL EMPTY CONDUITS FOR PARKING GATE CONTROL WIRING INSTALLED BY THE PARKING GATE VENDOR. 02 PROVIDE 120V POWER FOR EMERGENCY CALL STATION. 03 EMPTY 1" CONDUITS FOR APARTMENT FEEDS STUBBED INTO THE APARTMENT CORRIDOR FOR FUTURE EXTENSION BY OTHERS. EC TO VERIFY HEIGHT AND COORDINATE WITH EV CHARGER PROVIDER FOR CONNECTION METHOD. SEE CONDO DRAWINGS.. 04 PROVIDE CONDUIT AND BOX ROUGH-IN FOR GATE INDICATOR LIGHT INSTALLED BY GATE VENDOR. 05 DUCTLESS SPLIT SYSTEM FOR ELEVATOR VESTIBULE. 06 GARAGE LIGHTING TO REMAIN POWERED AT ALL TIME. 07 TIME CLOCK TO CONTROL BLADE SIGNS. 08 EMERGENCY CIRCUITS ARE NOT TO BE COMBINED WITH GENERAL LIGHTING CIRCUITS PER NEC 700. WP 02DS-1 No. Description Date 1 ISSUE FOR PERMIT 10/25/ 2021