Loading...
HomeMy WebLinkAboutS001.0 - HAM 37 - 3 Foundation 9.13.21GARY NANCE DESIGNArchitectural Concepts ByMake yourself at home4631 Lisborn Drive Carmel, IN 46033317.663.4793 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance Design3 SCALE: 1/4"=1'-0" FOUNDATION PLAN 12"x18" ANCHOR BOLTS 48" O.C. AIR SPACE BRICK VENEER FD5 FOUNDATION DETAIL7"534"12"X22" DEEP CONCRETE FOOTING @ 2500 PSI R-10 RIGID INSULATION 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI 12"x18" ANCHOR BOLTS 48" O.C. HOUSE SLABHOUSE SLAB GARAGE SLAB TOP OF MAIN LEVEL SUB FLOOR 12" EDGE FD1 FOUNDATION DETAIL FD2 FOUNDATION DETAIL FD3 FOUNDATION DETAIL FD4 FOUNDATION DETAIL Hamlet Lot 37Marc Luros TownhouseTHICKENED SLAB THICKENED EDGEUNEXCAVATED - 4" MIN. CONCRETE SLAB - GRAVEL FILL UNEXCAVATED - 4" MIN. CONCRETE SLAB - GRAVEL FILL EPOXY FLOOR WATER SOFTNER R.I.DW.W. SINK REF. D. GAS WINE FRIDGE U.C. ICEMAKERDBLE. WALL BEHIND W/D 90'-7" 27'-5"5'-212"33'-0" 24'-111 2" 51 2" 4'-312" 51 2" 65'-712" 17'-0" 712"10'-4"1'-912"16'-3"2'-8" 13'-212"33'-11"6'-0" 7'-23 16" 7'-23 16" 20'-9" 52'-7" 7" 3'-0" 11'-1" 3'-8"3'-8"8" 21'-3" 94'-7"8"20'-4"8'-5" 712" 912" 912" MASTER SHOWER DROP 4" 1'-312"3'-10"door opg. stationary door 3'-0" 3'-1" 2" MINIMUM SLOPED CONCRETE SLAB THICKENED SLAB12'-6"21'-5"2'-8"7'-2" 2'-8"1'-112"1'-2" 6'-0" 1'-2"1112"3'-10" 612"2'-9"612"1'-112"7"1112"7"2'-0"33'-11"UNEXCAVATED - 4" MIN. CONCRETE SLAB - GRAVEL FILL UNEXCAVATED - 4" MIN. CONCRETE SLAB - GRAVEL FILL 91 2" 712"R-10 RIGID INSULATIONdoor opg.R-10 RIGID INSULATION (1)FLR. OUTLET LOCATION T.B.D. ELEVATOR 42"x42"x12" THK. CONC. FOOTING 42"x42"x12" THK. CONC. FOOTING R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION RECESSED 8" VERIFY w/ ELEVATOR MANUFACTURER/ CONTRACTOR FOR SPECS. R-10 RIGID INSULATION 9'-1"5'-3"10"3'-0" 7'-912"door opg. 5'-8"512"19'-1112" 11'-314"1'-4"20'-434" LINE OF GARAGE CLOSET 6'-1058" 1'-4" 4'-9"THICKENED SLABR-10 RIGID INSULATION R-10 RIGIDINSULATIONGAS TANKLESS W.H. w/RECIRCULATING PUMP 1'-234"912"712"09.13.2021634"17'-6" 2 STORY STL COLUMN 2 STORY STL COLUMN 2 STORY STL COLUMN 18'-33 4" 1'-114" 7'-61 2" 6'-51 4"5'-3"4'-712"19'-5"24"x24"x12" THK. CONC. FOOTING 24"x24"x12" THK. CONC. FOOTING 24"x24"x12" THK. CONC. FOOTING STL BEAM TOP OF STEEL AT 9'-115 8" 2 STORY STL COLUMN 634"1 STORY STL COLUMN 1 STORY STL COLUMN STL COLUMN ON BEAM STL BEAM BOTTOM OF STEEL AT 10'-118" 10/27/21