Loading...
HomeMy WebLinkAboutA306 - BLDG A - ENLARGED ELEVATIONS AND WALL SECTIONS7 A231 E F 27 A306 28 A306 3 G WINDOW AS SCHEDULED METAL COPING SYSTEM 5/4x6 FIBER CEMENT TRIM, PTD., TYP. FIBER CEMENT LAP SIDING (7" EXPOSURE), PTD. FIBER CEMENT TRIM , PTD. BRICK VENEER BRICK ROWLOCK COURSE FIBER CEMENT PANEL AND TRIM, PTD. 5/4x8 FIBER CEMENT TRIM, PTD., TYP., ALIGN WITH FOURTH FLOOR SUBFLOOR PREFINISHED METAL CONDUCTOR HEAD AND DOWNSPOUT STOREFRONT AS SCHEDULED FIBER CEMENT TRIM, PTD., TYP. 5/4x6 FIBER CEMENT TRIM, PTD., TYP. 9 A520 8'-0"8'-0"8'-0"8'-0"SCUPPER XVENT, PTD. REF. MECHANICAL 16 A540 13 A502 BLDG A L 05 +871' -10 1/16" BLDG A TRUSS BEARING +880' -11 3/16" BLDG A L 02 +839' -10 7/16" BLDG A L 03 +850' -6 5/16" BLDG A L 04 +861' -2 3/16" 3 BLDG A L 01.3 +821' -3 19/32"T.O. CONC. SLAB TO B.O. TRUSS9'-1 1/8"TRUSS1'-6"3/4" SUBFLOORT.O. SUBFLOOR TO B.O. TRUSS9'-1 1/8"TRUSS1'-6"3/4" SUBFLOORT.O. SUBFLOOR TO B.O. TRUSS9'-1 1/8"TRUSS1'-6"3/4" SUBFLOORT.O. SUBFLOOR TO B.O. TRUSS9'-1 1/8"T.O. CONC. SLAB TO T.O. SUBFLOOR10'-7 7/8"T.O. SUBFLOOR TO T.O. SUBFLOOR10'-7 7/8"T.O. SUBFLOOR TO T.O. SUBFLOOR10'-7 7/8"T.O. CONC. SLAB TO T.O. TOPPING10'-9 1/8"T.O. TOPPING TO T.O. TOPPING10'-7 7/8"T.O. TOPPING TO T.O. TOPPING10'-7 7/8"1 1/4" TOPPING1 1/4" TOPPING1 1/4" TOPPING1'-2" CONC. SLABT.O. CONC SLAB TO B.O. CONC SLAB17'-4 13/16"T.O. CONC SLAB TO T.O. CONC SLAB18'-6 13/16"3'-0"HEEL HGT.2'-0"CONCRETE SLAB OVER VAPOR BARRIER, REF. STRUCTURAL PREFABRICATED ROOF TRUSSES, TYP., RE: STRUCTURAL 5/4x6 FIBER CEMENT HEAD TRIM, PTD., TYP. FIBER CEMENT LAP SIDING (7" EXPOSURE), PTD. BRICK VENEER DOOR AS SCHEDULED, TYP. BRICK ROWLOCK 2 1A 1A 3 SINGLE PLY ROOFING MEMBRANE SYSTEM METAL COPING SYSTEM FIBER CEMENT, PTD. BALCONY WITH METAL PICKET RAILING, PTD. 28 A511 25 A511 A 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.7/16/2021 3:34:51 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 A306 BLDG A -ENLARGED ELEVATIONS AND WALL SECTIONS The Corner Carmel, IN VWB DSPThe Corner Carmel, IN • 01.18066.00 1685 E. 116th Street, Carmel, IN SCALE: 1/4" = 1'-0" 25 BUILDING A - ENLARGED SOUTH ELEVATION SCALE: 1/4" = 1'-0" 27 WALL SECTION SCALE: 1/4" = 1'-0" 28 WALL SECTION 06.16.21 Permit Set A 07.15.21 Addendum A