Loading...
HomeMy WebLinkAboutA113b - PARTIAL THIRD FLOOR PLANS - BUILDING AKEY PLANGENERAL PLAN NOTESFIRE RESISTANCE RATED SEPARATION LEGEND 25 A205 7 A205 MATCHLINEREFER TO28 / A113aMATCHLINEREFER TO28 / A113aELEV. A1 SHAFT SHAFT TELECOMM. A346 MECH. A345 ELEC.A344STORAGE A343 STAIR A1 CORRIDOR A342 25 A401 A1d A333 A1d A331 A1d A329 A1c A327 B1d alt1 A328 B1k A336 A1f A339 B1r A338 S1 A335 B1e A330 A1d A337 28 A161a 28 A161a 28 A161a 28 A161a 29 A151 29 A171a 13 A171a 17 A171a 27 A171a 17 A161a 26 A161a S1 alt2 A334 A1 alt2 A332 17 A161 23 A151a35'-0"1" A.S.31'-6"24'-2"1" A.S.23'-10"1" A.S.24'-0"1" A.S.18'-0"1" A.S.24'-0"1" A.S.24'-0"1" A.S.24'-0"1" A.S.24'-0"4" F.W.6'-6 3/4" 36'-2"1" A.S.36'-0"1" A.S.18'-0"1" A.S.24'-0"1" A.S.36'-0"1" A.S.36'-0"4" F.W. A341a 25 A119FEC A FEC BUILDING B GARAGE BUILDING A1. ALL DIMENSIONS ON OVERALL OR BUILDING FLOOR PLANS ARE FROM FACE-OF STUD TO FACE-OF-STUD UNLESS NOTED OTHERWISE. 2. ORIENTATION OF THE BUILDING FLOOR PLAN ILLUSTRATED MAY BE DIFFERENT THAN THE ORIENTATION ON THE ARCHITECTURAL REFERENCE SITE PLAN. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 3. REFERENCE SHEETS A151-175 FOR ADDITIONAL INFORMATION ON RESIDENTIAL UNITS, WINDOW DESIGNATIONS, AND LOCATION. 4. EXTERIOR AND CORRIDOR STUDS NOT DIMENSIONED ARE 2x6 WOOD STUDS AND INTERIOR STUDS NOT DIMENSIONED ARE 2x4 WOOD STUDS TYPICAL UNLESS NOTED OTHERWISE. REFERENCE STRUCTURAL DRAWINGS FOR WALL FRAMING AND SPACING. 5. USE FIRE RATED 5/8" GYPSUM BOARD AT RATED WALLS. REFER TO RATED ASSEMBLIES FOR USE OF EITHER TYPE 'X' OR TYPE 'C' 6. ALL MECHANICAL, ELECTRICAL, PLUMBING, SECURITY, UTILITY, CABLE TV, AND TELEPHONE EQUIPMENT SHALL BE INSTALLED SO AS NOT TO BE IN CONFLICT WITH ANY WINDOW, WINDOW SHUTTER, OR SHUTTER PANEL. 7. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL EXTERIOR WALLS. ALL EXTERIOR CONCRETE PATIOS SHALL BE SLOPED DOWN AWAY FROM THE BUILDING AT 1/8" PER FOOT. 30 MIN RATED PARTITION FOR OCCUPANCY SEPARATION 1 HOUR RATED PARTITION 2 HOUR RATED PARTITION NOTES: 1. PROVIDE REQUIRED SEPARATION PROTECTION INCLUDING REQUIRED RATING OF OPENINGS, PROPER PENETRATION PROTECTION, ETC. AT ALL FIRE RESISTANT PARTITIONS. 2. CORRIDOR LOAD BEARING WALLS ARE REQUIRED TO BE PROVIDED WITH 1 HOUR FIRE- RESISTANCE PROTECTION FOR ASSEMBLY AS REQUIRED BY IBC TABLE 601, BUT DOES NOT REQUIRE INCREASE IN OPENING PROTECTION OVER 20 MIN. PER IBC 708.3 EXCEPTION 1 AND TABLE 1020.1, UNLESS OTHERWISE REQUIRED DUE TO NEEDED SEPARATION PROTECTION. 3. IN ADDITION TO WALLS HAVING REQUIRED FIRE-RESISTANCE RATED SEPARATION PROTECTION, ALL EXTERIOR AND INTERIOR LOAD BEARING WALLS AND PRIMARY STRUCTURAL FRAME ELEMENTS ARE REQUIRED TO BE 1-HOUR FIRE RESISTANCE PROTECTED AS REQUIRED BY IBC TABLE 601 AND TABLE 602. SHOWN WITH SOLID HATCH FOR CLARITY.50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.FOR REVIEW ONLY - NOT FOR CONSTRUCTION7/16/2021 2:03:23 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvt07.15.21LRK Project Number: 01.18066.00 A113b PARTIAL THIRD FLOOR PLANS -BUILDING A The Corner Carmel, IN VWB SWM 1685 E. 116th Street, Carmel, INThe Corner Carmel, IN • 01.18066.00 SCALE: 1/8" = 1'-0" 25 PARTIAL THIRD FLOOR PLAN - BUILDING A 28/A113b 06.16.21 Permit Set A 07.15.21 Addendum A