A114a - PARTIAL FOURTH FLOOR PLANS - BUILDING A
KEY PLANGENERAL PLAN NOTESFIRE RESISTANCE RATED SEPARATION LEGEND BUILDING B GARAGE BUILDING A 10 A204 MATCHLINE REFER TO 28 / A114a MATCHLINE REFER TO 28 / A114a ELEV. A2 SHAFT SHAFTSHAFTSHAFT SHAFT MECH. CLST.CORRIDORA44013 A201 A2b A405 A1d A407 A1d A413 S1 alt.1 A403 S1 A409 B1f A404 B1e alt1 A410 A1d A411 29 A161 29 A151 29 A162a 17 A171a 15 A171a 28 A161a 28 A161a 29 A151a A1b A415 29 A161a A2g A412 28 A162a 8 A402 Sim 34'-9"31'-10"1" A.S.24'-0"1" A.S.24'-0"1" A.S.24'-0"1" A.S.18'-0"1" A.S.24'-0"1" A.S.27'-0"1" A.S.8'-3"16'-4"24'-2"38'-6"1" A.S.36'-0"1" A.S.24'-0"1" A.S.18'-0"2" A.S.36'-0"1" A.S.27'-0"1" A.S.A440b A440dA440eA440fA440gA45229 A119 29 A117 6 A111c Sim B3 A402 29 A173 A1 alt3 A406 S1 alt3 A408 16 A161 11 A151a TELECOMM.A440cFECFECA1 alt 4 A401 14 A161 STAIR A2 A450 A 7A2027A204MATCHLINE REFER TO 25 / A114a MATCHLINE REFER TO 25 / A114a MATCHLINEREFER TO25 / A114bMATCHLINEREFER TO25 / A114bSHAFTSHAFTSHAFTSHAFTSHAFT MECH. CLST.SHAFT CORRIDOR A441 STAIR A3 A449 9 A403 Sim SHAFT A2n A422 A1d A421 A1d A423 B4 A424 B4 A418 A2m A420 A3 A419 S2 A416 29 A174 29 A174 16 A162a 26 A162a 28 A161a 28 A161a 29 A163 29 A152 S1a A417 A2f A414 27 A151a 17 A162a A3 A425 S2 A426 29 A163 29 A152 4" F.W.21'-0"1" A.S.14'-7 1/4"1" A.S.18'-0"4" F.W.6'-6 3/4"10'-3"1" A.S.24'-0"1" A.S.24'-0"3/4" A.S.10'-0"1/2" A.S.10'-3"38'-11 3/4"1" A.S.27'-0"1" A.S.27'-0"1" A.S.38'-11 3/4"14'-9 3/4"1" A.S.21'-0"4" F.W.27'-0"1" A.S.4" F.W.6'-6 3/4"A440hA440a A441b A441c A453 A441e A441f A441a A442a 7 A119 30 A119TELECOMM.FECA A FEC 1. ALL DIMENSIONS ON OVERALL OR BUILDING FLOOR PLANS ARE FROM FACE-OF STUD TO FACE-OF-STUD UNLESS NOTED OTHERWISE. 2. ORIENTATION OF THE BUILDING FLOOR PLAN ILLUSTRATED MAY BE DIFFERENT THAN THE ORIENTATION ON THE ARCHITECTURAL REFERENCE SITE PLAN. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 3. REFERENCE SHEETS A151-175 FOR ADDITIONAL INFORMATION ON RESIDENTIAL UNITS, WINDOW DESIGNATIONS, AND LOCATION. 4. EXTERIOR AND CORRIDOR STUDS NOT DIMENSIONED ARE 2x6 WOOD STUDS AND INTERIOR STUDS NOT DIMENSIONED ARE 2x4 WOOD STUDS TYPICAL UNLESS NOTED OTHERWISE. REFERENCE STRUCTURAL DRAWINGS FOR WALL FRAMING AND SPACING. 5. USE FIRE RATED 5/8" GYPSUM BOARD AT RATED WALLS. REFER TO RATED ASSEMBLIES FOR USE OF EITHER TYPE 'X' OR TYPE 'C' 6. ALL MECHANICAL, ELECTRICAL, PLUMBING, SECURITY, UTILITY, CABLE TV, AND TELEPHONE EQUIPMENT SHALL BE INSTALLED SO AS NOT TO BE IN CONFLICT WITH ANY WINDOW, WINDOW SHUTTER, OR SHUTTER PANEL. 7. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL EXTERIOR WALLS. ALL EXTERIOR CONCRETE PATIOS SHALL BE SLOPED DOWN AWAY FROM THE BUILDING AT 1/8" PER FOOT. 30 MIN RATED PARTITION FOR OCCUPANCY SEPARATION 1 HOUR RATED PARTITION 2 HOUR RATED PARTITION NOTES: 1. PROVIDE REQUIRED SEPARATION PROTECTION INCLUDING REQUIRED RATING OF OPENINGS, PROPER PENETRATION PROTECTION, ETC. AT ALL FIRE RESISTANT PARTITIONS. 2. CORRIDOR LOAD BEARING WALLS ARE REQUIRED TO BE PROVIDED WITH 1 HOUR FIRE- RESISTANCE PROTECTION FOR ASSEMBLY AS REQUIRED BY IBC TABLE 601, BUT DOES NOT REQUIRE INCREASE IN OPENING PROTECTION OVER 20 MIN. PER IBC 708.3 EXCEPTION 1 AND TABLE 1020.1, UNLESS OTHERWISE REQUIRED DUE TO NEEDED SEPARATION PROTECTION. 3. IN ADDITION TO WALLS HAVING REQUIRED FIRE-RESISTANCE RATED SEPARATION PROTECTION, ALL EXTERIOR AND INTERIOR LOAD BEARING WALLS AND PRIMARY STRUCTURAL FRAME ELEMENTS ARE REQUIRED TO BE 1-HOUR FIRE RESISTANCE PROTECTED AS REQUIRED BY IBC TABLE 601 AND TABLE 602. SHOWN WITH SOLID HATCH FOR CLARITY.50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.7/16/2021 2:03:34 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 A114a PARTIAL FOURTH FLOOR PLANS -BUILDING A The Corner Carmel, IN VWB SWMThe Corner Carmel, IN • 01.18066.00 1685 E. 116th Street, Carmel, IN25/A114a28/A114aSCALE: 1/8" = 1'-0" 25 PARTIAL FOURTH FLOOR PLAN - BUILDING A SCALE: 1/8" = 1'-0" 28 PARTIAL FOURTH FLOOR PLAN - BUILDING A 06.16.21 Permit Set A 07.15.21 Addendum A