Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A121a - PARTIAL GROUND FLOOR PLAN - BUILDING B
KEY PLANGENERAL PLAN NOTESFIRE RESISTANCE RATED SEPARATION LEGEND 19 A214 7 A212 19 A215 TRASH B123a MATCHLINEREFER TO25 / A121bMATCHLINEREFER TO25 / A121bS2b B124 A2j B130 B1c B132 A1k B134 B1p B136 ASSIGNABLE GARAGE B135b ASSIGNABLE GARAGE B135a ASSIGNABLE GARAGE B133b ASSIGNABLE GARAGE B133a ASSIGNABLE GARAGE B131c ASSIGNABLE GARAGE B131b ASSIGNABLE GARAGE B131a ASSIGNABLE GARAGE B127b ASSIGNABLE GARAGE B127a ASSIGNABLE GARAGE B125a ASSIGNABLE GARAGE B125b ASSIGNABLE GARAGE B123b 31'-6"6'-5"28'-4"ELEV. B1 MECH B168 STORAGE B169 STORAGE B170 TELECOMM. B172 STORAGE B173 STORAGE B176 STORAGE B177 STORAGE B179 STORAGE B180 MECH. B181 STORAGEB183STAIR B3B18227 A414 29 A413 25 A126 15 A126 28 A161b 28 A162c 27 A171b 17 A152a 28 A171c ELEVATOR CONTROL ROOM B167 A2j alt2 B122 1" A.S.8'-11"1" A.S.27'-0"1" A.S.21'-0"1" A.S.24'-0"4" F.W.27'-0"1" A.S.27'-0"1" A.S.36'-0"1" A.S.24'-0"1" A.S.36'-8" 29 A162c A1h B126 27 A161b A2d B128 28 A162b 2'-0"2'-0"STORAGE B166 ASSIGNABLE GARAGE B125c STORAGE B178 LOBBY B140 STORAGE B175 STORAGE B174 ASSIGNABLE GARAGE B129a ASSIGNABLE GARAGE B129b ELEC B171 CORRIDOR B139 LOBBY B165 10'-2"35'-0"1" A.S.36'-0"4" F.W.27'-0"1" A.S.27'-0"1" A.S.36'-0"1" A.S.24'-0"1" A.S.27'-0"1/2" A.S.9'-8" SC1 SBFECFEC SC1 A BUILDING BGARAGE BUILDING A 1. ALL DIMENSIONS ON OVERALL OR BUILDING FLOOR PLANS ARE FROM FACE-OF STUD TO FACE-OF-STUD UNLESS NOTED OTHERWISE. 2. ORIENTATION OF THE BUILDING FLOOR PLAN ILLUSTRATED MAY BE DIFFERENT THAN THE ORIENTATION ON THE ARCHITECTURAL REFERENCE SITE PLAN. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 3. REFERENCE SHEETS A151-175 FOR ADDITIONAL INFORMATION ON RESIDENTIAL UNITS, WINDOW DESIGNATIONS, AND LOCATION. 4. EXTERIOR AND CORRIDOR STUDS NOT DIMENSIONED ARE 2x6 WOOD STUDS AND INTERIOR STUDS NOT DIMENSIONED ARE 2x4 WOOD STUDS TYPICAL UNLESS NOTED OTHERWISE. REFERENCE STRUCTURAL DRAWINGS FOR WALL FRAMING AND SPACING. 5. USE FIRE RATED 5/8" GYPSUM BOARD AT RATED WALLS. REFER TO RATED ASSEMBLIES FOR USE OF EITHER TYPE 'X' OR TYPE 'C' 6. ALL MECHANICAL, ELECTRICAL, PLUMBING, SECURITY, UTILITY, CABLE TV, AND TELEPHONE EQUIPMENT SHALL BE INSTALLED SO AS NOT TO BE IN CONFLICT WITH ANY WINDOW, WINDOW SHUTTER, OR SHUTTER PANEL. 7. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL EXTERIOR WALLS. ALL EXTERIOR CONCRETE PATIOS SHALL BE SLOPED DOWN AWAY FROM THE BUILDING AT 1/8" PER FOOT. 30 MIN RATED PARTITION FOR OCCUPANCY SEPARATION 1 HOUR RATED PARTITION 2 HOUR RATED PARTITION NOTES: 1. PROVIDE REQUIRED SEPARATION PROTECTION INCLUDING REQUIRED RATING OF OPENINGS, PROPER PENETRATION PROTECTION, ETC. AT ALL FIRE RESISTANT PARTITIONS. 2. CORRIDOR LOAD BEARING WALLS ARE REQUIRED TO BE PROVIDED WITH 1 HOUR FIRE- RESISTANCE PROTECTION FOR ASSEMBLY AS REQUIRED BY IBC TABLE 601, BUT DOES NOT REQUIRE INCREASE IN OPENING PROTECTION OVER 20 MIN. PER IBC 708.3 EXCEPTION 1 AND TABLE 1020.1, UNLESS OTHERWISE REQUIRED DUE TO NEEDED SEPARATION PROTECTION. 3. IN ADDITION TO WALLS HAVING REQUIRED FIRE-RESISTANCE RATED SEPARATION PROTECTION, ALL EXTERIOR AND INTERIOR LOAD BEARING WALLS AND PRIMARY STRUCTURAL FRAME ELEMENTS ARE REQUIRED TO BE 1-HOUR FIRE RESISTANCE PROTECTED AS REQUIRED BY IBC TABLE 601 AND TABLE 602. SHOWN WITH SOLID HATCH FOR CLARITY.50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.7/16/2021 2:18:33 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 A121a PARTIAL GROUND FLOOR PLAN -BUILDING B The Corner Carmel, IN VWB SWMThe Corner Carmel, IN • 01.18066.00 1685 E. 116th Street, Carmel, IN SCALE: 1/8" = 1'-0" 25 PARTIAL GROUND FLOOR PLAN - BUILDING B 25/A121a 06.16.21 Permit Set A 07.15.21 Addendum A