Loading...
HomeMy WebLinkAboutA121b - PARTIAL GROUND FLOOR PLANS - BUILDING BVITREO US CHINABATHRO O M SINKVO XK-5373 KEY PLANGENERAL PLAN NOTESFIRE RESISTANCE RATED SEPARATION LEGEND 7 A215 RISER RM. B184 PET WASH B101a MATCHLINE REFER TO 25 / A121b MATCHLINE REFER TO 25 / A121b B1n B108 A1n B102 1 A171b ASSIGNABLE GARAGE B101b ASSIGNABLE GARAGE B103 ASSIGNABLE GARAGE B105 ASSIGNABLE GARAGE B107a ASSIGNABLE GARAGE B107b ASSIGNABLE GARAGE B107c S1b B106 A2j B104 24'-8"1" A.S.27'-0"1" A.S.18'-0"1" A.S.36'-0"1" A.S.24'-2"9'-9" A.S.18'-0"1" A.S.18'-0"1" A.S.36'-0"1" A.S.31'-6"12'-11"23'-0" CORRIDOR B137 MECH. B141 STORAGE B142a STORAGE B143 STORAGE B144 STORAGE B146 STORAGE B147 MECH B145 27 A412 21 A151a 28 A162c 25 A161b 22 A127 28 A127 STORAGE B148 FECFECSTAIR B2 B142 19 A212 MATCHLINEREFER TO25 / A121aMATCHLINE REFER TO 28 / A121b MATCHLINE REFER TO 28 / A121b 7 A213 7 A211 13 A211 A2j alt 1 B119 A2j B118 A2h alt 1 B117 A2h B116 A1k B114 B1h B112 A1h B110 CO WORK B113 ASSIGNABLE GARAGE B109a ASSIGNABLE GARAGE B109b ASSIGNABLE GARAGE B111a ASSIGNABLE GARAGE B111b ASSIGNABLE GARAGE B121a ASSIGNABLE GARAGE B121b27'-2"9'-9"27'-0"1" A.S.27'-0"1" A.S.24'-0"1" A.S.36'-0"4" F.W.24'-0"1" A.S.31'-6"5'-3"29'-6" STORAGE B148 STORAGE B149 STORAGE B150 STORAGEB164MECH. B153 STAIR B1 B154 MECH B163 27 A411 PACKAGE B113a OFFICE B113b OFFICE B113c CONFERENCE B113d STORAGE B111c UNISEX B152 ELEC. B151 B2 B115 29 A172 28 A162c 15 A162b 28 A161b 28 A161b 25 A171b 29 A162c 17 A162b MATCHLINEREFER TO25 / A121a25 A127 A2h B120 35'-7"1"26'-11" 15 A162b 1" A.S.27'-0"1" A.S.36'-2"4" F.W.24'-0"1" A.S.FECSC11A212 2 A212 29 A212 10 A121b 36'-0"1"27'-2"A BUILDING B GARAGE BUILDING A 1. ALL DIMENSIONS ON OVERALL OR BUILDING FLOOR PLANS ARE FROM FACE-OF STUD TO FACE-OF-STUD UNLESS NOTED OTHERWISE. 2. ORIENTATION OF THE BUILDING FLOOR PLAN ILLUSTRATED MAY BE DIFFERENT THAN THE ORIENTATION ON THE ARCHITECTURAL REFERENCE SITE PLAN. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 3. REFERENCE SHEETS A151-175 FOR ADDITIONAL INFORMATION ON RESIDENTIAL UNITS, WINDOW DESIGNATIONS, AND LOCATION. 4. EXTERIOR AND CORRIDOR STUDS NOT DIMENSIONED ARE 2x6 WOOD STUDS AND INTERIOR STUDS NOT DIMENSIONED ARE 2x4 WOOD STUDS TYPICAL UNLESS NOTED OTHERWISE. REFERENCE STRUCTURAL DRAWINGS FOR WALL FRAMING AND SPACING. 5. USE FIRE RATED 5/8" GYPSUM BOARD AT RATED WALLS. REFER TO RATED ASSEMBLIES FOR USE OF EITHER TYPE 'X' OR TYPE 'C' 6. ALL MECHANICAL, ELECTRICAL, PLUMBING, SECURITY, UTILITY, CABLE TV, AND TELEPHONE EQUIPMENT SHALL BE INSTALLED SO AS NOT TO BE IN CONFLICT WITH ANY WINDOW, WINDOW SHUTTER, OR SHUTTER PANEL. 7. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL EXTERIOR WALLS. ALL EXTERIOR CONCRETE PATIOS SHALL BE SLOPED DOWN AWAY FROM THE BUILDING AT 1/8" PER FOOT. 30 MIN RATED PARTITION FOR OCCUPANCY SEPARATION 1 HOUR RATED PARTITION 2 HOUR RATED PARTITION NOTES: 1. PROVIDE REQUIRED SEPARATION PROTECTION INCLUDING REQUIRED RATING OF OPENINGS, PROPER PENETRATION PROTECTION, ETC. AT ALL FIRE RESISTANT PARTITIONS. 2. CORRIDOR LOAD BEARING WALLS ARE REQUIRED TO BE PROVIDED WITH 1 HOUR FIRE- RESISTANCE PROTECTION FOR ASSEMBLY AS REQUIRED BY IBC TABLE 601, BUT DOES NOT REQUIRE INCREASE IN OPENING PROTECTION OVER 20 MIN. PER IBC 708.3 EXCEPTION 1 AND TABLE 1020.1, UNLESS OTHERWISE REQUIRED DUE TO NEEDED SEPARATION PROTECTION. 3. IN ADDITION TO WALLS HAVING REQUIRED FIRE-RESISTANCE RATED SEPARATION PROTECTION, ALL EXTERIOR AND INTERIOR LOAD BEARING WALLS AND PRIMARY STRUCTURAL FRAME ELEMENTS ARE REQUIRED TO BE 1-HOUR FIRE RESISTANCE PROTECTED AS REQUIRED BY IBC TABLE 601 AND TABLE 602. SHOWN WITH SOLID HATCH FOR CLARITY. 16 A511 CO WORK B113 PAC-750 ALUMINUM FULL VENT SOFFIT, DARK BRONZE FINISH J-CHANNEL AROUND THE PERIMETER LVL STRUCTURAL BEAM, REF. STRUCTURAL 3'-7"EQ EQ EQ 4" RECESSED CAN WITH ESCUTCHEON COVER, REF. ELECTRICAL EQ EQ WALL SCONCEEQEQ 2 A212 29 A212 A 7 7/8"11'-0 1/2"5 3/8"CLEQ EQ 5'-3" G C C G 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.7/16/2021 3:26:19 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 A121b PARTIAL GROUND FLOOR PLANS -BUILDING B The Corner Carmel, IN VWB SWMThe Corner Carmel, IN • 01.18066.00 1685 E. 116th Street, Carmel, IN SCALE: 1/8" = 1'-0" 28 PARTIAL GROUND FLOOR PLAN - BUILDING B SCALE: 1/8" = 1'-0" 25 PARTIAL GROUND FLOOR PLAN - BUILDING B 25/A121b28/A121bSCALE: 1/4" = 1'-0" 11 REFLECTED CEILING PLAN - COWORKING SCALE: 1/4" = 1'-0" 10 PLAN DETAIL - BUILDING B 06.16.21 Permit Set A 07.15.21 Addendum A