Loading...
HomeMy WebLinkAboutA123a - PARTIAL THIRD FLOOR PLAN - BUILDING BKEY PLANGENERAL PLAN NOTESFIRE RESISTANCE RATED SEPARATION LEGEND BUILDING BGARAGE BUILDING A 19 A215 13 A231 MATCHLINEREFER TO25 / A123bMATCHLINEREFER TO25 / A123bELEV. B1 MECH. B384 STAIR B3 B382 CORRIDOR B339 LOBBY B365 13 A414 S2a B324 A2k B330 B1b B332 A1j B334 B1q B336 A1 B333 B1 B331 A2 B329 17 A161b 29 A161 29 A171 16 A162c 29 A162 15 A171c 17 A171b 29 A152a A4 B323 15 A413 Sim 28 A164 1" A.S.36'-0"1" A.S.21'-0"1" A.S.24'-0"4" F.W.27'-0"1" A.S.27'-0"1" A.S.36'-0"1" A.S.24'-0"1" A.S.36'-10" A2c B328 A1g B326 B1a B325 A2a B327 A2 B335 15 A161b 18 A162b 29 A171b 29 A162b 29 A162 CORRIDOR B338 2'-0"2'-0"1" A.S.10'-3"34'-10"1" A.S.36'-0"4" F.W.27'-0"1" A.S.27'-0"1" A.S.36'-0"1" A.S.24'-0"1" A.S.27'-0"1/2" A.S.9'-8"31'-6"6'-5"28'-4"B339a B1m B322 13 A171b FEC FEC31'-6"5'-3"29'-6"29'-6"5'-3"29'-6"31'-6"5'-3"29'-6"PEDESTRIAN BRIDGE A 1. ALL DIMENSIONS ON OVERALL OR BUILDING FLOOR PLANS ARE FROM FACE-OF STUD TO FACE-OF-STUD UNLESS NOTED OTHERWISE. 2. ORIENTATION OF THE BUILDING FLOOR PLAN ILLUSTRATED MAY BE DIFFERENT THAN THE ORIENTATION ON THE ARCHITECTURAL REFERENCE SITE PLAN. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 3. REFERENCE SHEETS A151-175 FOR ADDITIONAL INFORMATION ON RESIDENTIAL UNITS, WINDOW DESIGNATIONS, AND LOCATION. 4. EXTERIOR AND CORRIDOR STUDS NOT DIMENSIONED ARE 2x6 WOOD STUDS AND INTERIOR STUDS NOT DIMENSIONED ARE 2x4 WOOD STUDS TYPICAL UNLESS NOTED OTHERWISE. REFERENCE STRUCTURAL DRAWINGS FOR WALL FRAMING AND SPACING. 5. USE FIRE RATED 5/8" GYPSUM BOARD AT RATED WALLS. REFER TO RATED ASSEMBLIES FOR USE OF EITHER TYPE 'X' OR TYPE 'C' 6. ALL MECHANICAL, ELECTRICAL, PLUMBING, SECURITY, UTILITY, CABLE TV, AND TELEPHONE EQUIPMENT SHALL BE INSTALLED SO AS NOT TO BE IN CONFLICT WITH ANY WINDOW, WINDOW SHUTTER, OR SHUTTER PANEL. 7. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL EXTERIOR WALLS. ALL EXTERIOR CONCRETE PATIOS SHALL BE SLOPED DOWN AWAY FROM THE BUILDING AT 1/8" PER FOOT. 30 MIN RATED PARTITION FOR OCCUPANCY SEPARATION 1 HOUR RATED PARTITION 2 HOUR RATED PARTITION NOTES: 1. PROVIDE REQUIRED SEPARATION PROTECTION INCLUDING REQUIRED RATING OF OPENINGS, PROPER PENETRATION PROTECTION, ETC. AT ALL FIRE RESISTANT PARTITIONS. 2. CORRIDOR LOAD BEARING WALLS ARE REQUIRED TO BE PROVIDED WITH 1 HOUR FIRE- RESISTANCE PROTECTION FOR ASSEMBLY AS REQUIRED BY IBC TABLE 601, BUT DOES NOT REQUIRE INCREASE IN OPENING PROTECTION OVER 20 MIN. PER IBC 708.3 EXCEPTION 1 AND TABLE 1020.1, UNLESS OTHERWISE REQUIRED DUE TO NEEDED SEPARATION PROTECTION. 3. IN ADDITION TO WALLS HAVING REQUIRED FIRE-RESISTANCE RATED SEPARATION PROTECTION, ALL EXTERIOR AND INTERIOR LOAD BEARING WALLS AND PRIMARY STRUCTURAL FRAME ELEMENTS ARE REQUIRED TO BE 1-HOUR FIRE RESISTANCE PROTECTED AS REQUIRED BY IBC TABLE 601 AND TABLE 602. SHOWN WITH SOLID HATCH FOR CLARITY.50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.7/16/2021 2:19:08 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 A123a PARTIAL THIRD FLOOR PLAN -BUILDING B The Corner Carmel, IN VWB SWMThe Corner Carmel, IN • 01.18066.00 1685 E. 116th Street, Carmel, IN SCALE: 1/8" = 1'-0" 25 PARTIAL THIRD FLOOR PLAN - BUILDING B 25/A123a 06.16.21 Permit Set A 07.15.21 Addendum A