Loading...
HomeMy WebLinkAboutA123b - PARTIAL THIRD FLOOR PLANS - BUILDING BKEY PLANGENERAL PLAN NOTESFIRE RESISTANCE RATED SEPARATION LEGEND BUILDING B GARAGE BUILDING A 7 A211 MATCHLINEREFER TO25 / A123aMATCHLINEREFER TO25 / A123aMATCHLINE REFER TO 28 / A123b MATCHLINE REFER TO 28 / A123b TELECOMM.CORRIDOR B338 MECH. B353 STAIR B1 B354 A2e alt 1 B317 A2k B318 A2e B316 A1j B314 A1g B310 A1a B309 B1a B311 B1g A312 B2 B313 B2 B315 17 A161b 25 A162b 16 A162c 27 A162b 29 A172 15 A171b 15 A161b 29 A161b 29 A171b 29 A172 21 A411 Sim27'-2"1/2"9'-8"1/2"27'-0"1" A.S.27'-0"1" A.S.24'-0"1" A.S.36'-0"4" F.W.24'-0"1" A.S.35'-7"1" A.S.27'-0"1" A.S.1" A.S.24'-0"4" F.W.36'-0"1" A.S.36'-0"31'-6"5'-3"29'-6" B341 B338a A2 B321 A2e B320 35'-7"1" A.S.27'-0" 2'-0" 2'-0" 29 A162 25 A162b27'-2"1" A.S.36'-0"3'-0"FEC1A2122 A212 29 A212 10 A121b Sim A2k alt 1 B319 17 A162c A 7 A215 MATCHLINE REFER TO 25 / A123b MATCHLINE REFER TO 25 / A123b 24'-8"1" A.S.27'-0"1" A.S.18'-0"1" A.S.36'-0"1" A.S.6'-5"29'-6"24'-2"1/2" A.S.9'-8"1/2" A.S.18'-0"1" A.S.18'-0"1" A.S.36'-0"1" A.S.CORRIDOR B337 STAIR B2 B342 ELEC. B342a MECH. B340 B1m B308 S1 B306 A2k B304 A1m B302 A1 alt 1 B301 B1 B307 29 A151 13 A171b 29 A171 15 A161 13 A161b 16 A162c 21 A412 Sim B340 2'-0" 2'-0" 31'-6"1'-6"1'-4"2'-2"FECS1 alt4 B303 S1 alt5 B305 29 A151 29 A151 A 1. ALL DIMENSIONS ON OVERALL OR BUILDING FLOOR PLANS ARE FROM FACE-OF STUD TO FACE-OF-STUD UNLESS NOTED OTHERWISE. 2. ORIENTATION OF THE BUILDING FLOOR PLAN ILLUSTRATED MAY BE DIFFERENT THAN THE ORIENTATION ON THE ARCHITECTURAL REFERENCE SITE PLAN. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 3. REFERENCE SHEETS A151-175 FOR ADDITIONAL INFORMATION ON RESIDENTIAL UNITS, WINDOW DESIGNATIONS, AND LOCATION. 4. EXTERIOR AND CORRIDOR STUDS NOT DIMENSIONED ARE 2x6 WOOD STUDS AND INTERIOR STUDS NOT DIMENSIONED ARE 2x4 WOOD STUDS TYPICAL UNLESS NOTED OTHERWISE. REFERENCE STRUCTURAL DRAWINGS FOR WALL FRAMING AND SPACING. 5. USE FIRE RATED 5/8" GYPSUM BOARD AT RATED WALLS. REFER TO RATED ASSEMBLIES FOR USE OF EITHER TYPE 'X' OR TYPE 'C' 6. ALL MECHANICAL, ELECTRICAL, PLUMBING, SECURITY, UTILITY, CABLE TV, AND TELEPHONE EQUIPMENT SHALL BE INSTALLED SO AS NOT TO BE IN CONFLICT WITH ANY WINDOW, WINDOW SHUTTER, OR SHUTTER PANEL. 7. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL EXTERIOR WALLS. ALL EXTERIOR CONCRETE PATIOS SHALL BE SLOPED DOWN AWAY FROM THE BUILDING AT 1/8" PER FOOT. 30 MIN RATED PARTITION FOR OCCUPANCY SEPARATION 1 HOUR RATED PARTITION 2 HOUR RATED PARTITION NOTES: 1. PROVIDE REQUIRED SEPARATION PROTECTION INCLUDING REQUIRED RATING OF OPENINGS, PROPER PENETRATION PROTECTION, ETC. AT ALL FIRE RESISTANT PARTITIONS. 2. CORRIDOR LOAD BEARING WALLS ARE REQUIRED TO BE PROVIDED WITH 1 HOUR FIRE- RESISTANCE PROTECTION FOR ASSEMBLY AS REQUIRED BY IBC TABLE 601, BUT DOES NOT REQUIRE INCREASE IN OPENING PROTECTION OVER 20 MIN. PER IBC 708.3 EXCEPTION 1 AND TABLE 1020.1, UNLESS OTHERWISE REQUIRED DUE TO NEEDED SEPARATION PROTECTION. 3. IN ADDITION TO WALLS HAVING REQUIRED FIRE-RESISTANCE RATED SEPARATION PROTECTION, ALL EXTERIOR AND INTERIOR LOAD BEARING WALLS AND PRIMARY STRUCTURAL FRAME ELEMENTS ARE REQUIRED TO BE 1-HOUR FIRE RESISTANCE PROTECTED AS REQUIRED BY IBC TABLE 601 AND TABLE 602. SHOWN WITH SOLID HATCH FOR CLARITY.50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.7/16/2021 2:19:18 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 A123b PARTIAL THIRD FLOOR PLANS -BUILDING B The Corner Carmel, IN VWB SWMThe Corner Carmel, IN • 01.18066.00 1685 E. 116th Street, Carmel, IN SCALE: 1/8" = 1'-0" 25 PARTIAL THIRD FLOOR PLAN - BUILDING B SCALE: 1/8" = 1'-0" 28 PARTIAL THIRD FLOOR PLAN - BUILDING B 25/A123b28/A123b06.16.21 Permit Set A 07.15.21 Addendum A