Loading...
HomeMy WebLinkAboutA111b - PARTIAL GROUND FLOOR PLAN - BUILDING A819.23819.73820.23820.69821.13VITREO US CHINABATHRO O M SINKVO XK-5373 VITREO US CHINABATHRO O M SINKVO XK-5373 KEY PLANGENERAL PLAN NOTESFIRE RESISTANCE RATED SEPARATION LEGEND 25 A202 25 A205 7 A205 13 A23167'-3"72'-11"41'-10 1/2"78'-11 3/4" ELEV. A1 STAIR A1 PUMP ROOM A106 ELEC. A108 10 A205 4 A205 27 A401 26 A111c 13 111412 10 9 8 7 6 5 4 L M N A2 A3 SN1SJ7 A108 A107bA107c RETAIL SPACE A107 SJ6SJ6 NOTE: REFERENCE INTERIOR DESIGN DRAWINGS FOR ADDITIONAL NOTES, DETAILS, AND FINISHES FOR LEASING / AMENITY SO4 SJ6 SJ6 A107d A107e A107f A107g SJ2 SJ2 SJ2SJ2 22 A117 28 A117 13 A1196"6'-0 1/4"8'-7"6"MATCHLINEREFER TO28 / A111aMATCHLINEREFER TO28 / A111aDASHED LINE INDICATES LOCATION OF SHAFT OPENING IN CONCRETE PODIUM STEPLINE OF SLAB LEAVE-OUT SJ7 SJ4 SJ4 SJ4 SJ412'-1"CL14'-0"8'-0"5'-7"8'-0"5'-9"8'-0"11'-6"8'-0"8'-4" CL2'-5 1/2" IDF A112 11'-4 3/16"A 821' - 3 1/2" 818' - 6 1/2" DN NOTE:SEE 26/A111c FOR STOREFRONT KEYS H H L L L H A A A A A A 25 / A111b BUILDING B GARAGE BUILDING A1. ALL DIMENSIONS ON OVERALL OR BUILDING FLOOR PLANS ARE FROM FACE-OF STUD TO FACE-OF-STUD UNLESS NOTED OTHERWISE. 2. ORIENTATION OF THE BUILDING FLOOR PLAN ILLUSTRATED MAY BE DIFFERENT THAN THE ORIENTATION ON THE ARCHITECTURAL REFERENCE SITE PLAN. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 3. REFERENCE SHEETS A151-175 FOR ADDITIONAL INFORMATION ON RESIDENTIAL UNITS, WINDOW DESIGNATIONS, AND LOCATION. 4. EXTERIOR AND CORRIDOR STUDS NOT DIMENSIONED ARE 2x6 WOOD STUDS AND INTERIOR STUDS NOT DIMENSIONED ARE 2x4 WOOD STUDS TYPICAL UNLESS NOTED OTHERWISE. REFERENCE STRUCTURAL DRAWINGS FOR WALL FRAMING AND SPACING. 5. USE FIRE RATED 5/8" GYPSUM BOARD AT RATED WALLS. REFER TO RATED ASSEMBLIES FOR USE OF EITHER TYPE 'X' OR TYPE 'C' 6. ALL MECHANICAL, ELECTRICAL, PLUMBING, SECURITY, UTILITY, CABLE TV, AND TELEPHONE EQUIPMENT SHALL BE INSTALLED SO AS NOT TO BE IN CONFLICT WITH ANY WINDOW, WINDOW SHUTTER, OR SHUTTER PANEL. 7. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL EXTERIOR WALLS. ALL EXTERIOR CONCRETE PATIOS SHALL BE SLOPED DOWN AWAY FROM THE BUILDING AT 1/8" PER FOOT. 30 MIN RATED PARTITION FOR OCCUPANCY SEPARATION 1 HOUR RATED PARTITION 2 HOUR RATED PARTITION NOTES: 1. PROVIDE REQUIRED SEPARATION PROTECTION INCLUDING REQUIRED RATING OF OPENINGS, PROPER PENETRATION PROTECTION, ETC. AT ALL FIRE RESISTANT PARTITIONS. 2. CORRIDOR LOAD BEARING WALLS ARE REQUIRED TO BE PROVIDED WITH 1 HOUR FIRE- RESISTANCE PROTECTION FOR ASSEMBLY AS REQUIRED BY IBC TABLE 601, BUT DOES NOT REQUIRE INCREASE IN OPENING PROTECTION OVER 20 MIN. PER IBC 708.3 EXCEPTION 1 AND TABLE 1020.1, UNLESS OTHERWISE REQUIRED DUE TO NEEDED SEPARATION PROTECTION. 3. IN ADDITION TO WALLS HAVING REQUIRED FIRE-RESISTANCE RATED SEPARATION PROTECTION, ALL EXTERIOR AND INTERIOR LOAD BEARING WALLS AND PRIMARY STRUCTURAL FRAME ELEMENTS ARE REQUIRED TO BE 1-HOUR FIRE RESISTANCE PROTECTED AS REQUIRED BY IBC TABLE 601 AND TABLE 602. SHOWN WITH SOLID HATCH FOR CLARITY.50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.7/16/2021 2:34:04 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 A111b PARTIAL GROUND FLOOR PLAN -BUILDING A The Corner Carmel, IN VWB SWMThe Corner Carmel, IN • 01.18066.00 1685 E. 116th Street, Carmel, IN SCALE: 1/8" = 1'-0" 25 PARTIAL GROUND FLOOR PLAN - BUILDING A 06.16.21 Permit Set A 07.15.21 Addendum A