Loading...
HomeMy WebLinkAboutA113a - PARTIAL THIRD FLOOR PLANS - BUILDING AKEY PLANGENERAL PLAN NOTESFIRE RESISTANCE RATED SEPARATION LEGEND 7A2027A20426 A221 MATCHLINE REFER TO 25 / A113a MATCHLINE REFER TO 25 / A113a MATCHLINEREFER TO25 / A113bMATCHLINEREFER TO25 / A113bSHAFTSHAFTSHAFTSHAFTSHAFT MECH. CLST.SHAFT CORRIDOR A341 STAIR A3 A349 9 A403 A2n A322 A1d A321 A1d A323 S1a A317 B4 alt1 A324 B4 alt1 A318 A2m A320 A2f alt1 A314 A3 alt1 A319 S2 A316 29 A174 29 A174 16 A162a 26 A162a 28 A161a 28 A161a 29 A163 29 A152 27 A151a 17 A162a S2 A326 A3 alt1 A325 29 A163 29 A152 4" F.W.21'-0"1" A.S.14'-7 1/4"1" A.S.18'-0"4" F.W.6'-6 3/4"10'-3"1" A.S.24'-0"1" A.S.24'-0"3/4" A.S.10'-0"1/2" A.S.10'-3"38'-11 3/4"1" A.S.27'-0"1" A.S.27'-0"1" A.S.38'-11 3/4"14'-9 3/4"1" A.S.21'-0"4" F.W.27'-0"1" A.S.4" F.W.6'-6 3/4" A340 A353 7 A119 30 A119TELECOMM.FEC1" A.S.A A FEC 10 A204 MATCHLINE REFER TO 28 / A113a MATCHLINE REFER TO 28 / A113aELEV. A2SHAFT SHAFT SHAFTSHAFTSHAFT SHAFT MECH. CLST.CORRIDORA340STAIR A2 A350 8 A402 A2b A305 A1d A307 A1d A313 S1 alt.1 A303 S1 A309 B1f alt1 A304 B1e alt1 A310 A1d A311 29 A161 29 A151 29 A162a 17 A171a 15 A171a 28 A161a 28 A161a 29 A151a A1b A315 29 A161a A2g A312 28 A162a A35229 A119 29 A117 6 A111c Sim B3 alt1 A302 38'-6"1" A.S.36'-0"1" A.S.24'-0"1" A.S.18'-0"2" A.S.36'-0"1" A.S.27'-0"1" A.S.A1 alt3 A306 S1 alt3 A308 16 A161 11 A151a 29 A173 TELECOMM.FECFEC1" A.S.24'-0"1" A.S.24'-0"1" A.S.24'-0"1" A.S.18'-0"1" A.S.24'-0"1" A.S.27'-0"1" A.S.8'-3"16'-4"24'-2"34'-9"31'-10" A1 alt 4 A301 14 A161 A BUILDING B GARAGE BUILDING A 1. ALL DIMENSIONS ON OVERALL OR BUILDING FLOOR PLANS ARE FROM FACE-OF STUD TO FACE-OF-STUD UNLESS NOTED OTHERWISE. 2. ORIENTATION OF THE BUILDING FLOOR PLAN ILLUSTRATED MAY BE DIFFERENT THAN THE ORIENTATION ON THE ARCHITECTURAL REFERENCE SITE PLAN. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 3. REFERENCE SHEETS A151-175 FOR ADDITIONAL INFORMATION ON RESIDENTIAL UNITS, WINDOW DESIGNATIONS, AND LOCATION. 4. EXTERIOR AND CORRIDOR STUDS NOT DIMENSIONED ARE 2x6 WOOD STUDS AND INTERIOR STUDS NOT DIMENSIONED ARE 2x4 WOOD STUDS TYPICAL UNLESS NOTED OTHERWISE. REFERENCE STRUCTURAL DRAWINGS FOR WALL FRAMING AND SPACING. 5. USE FIRE RATED 5/8" GYPSUM BOARD AT RATED WALLS. REFER TO RATED ASSEMBLIES FOR USE OF EITHER TYPE 'X' OR TYPE 'C' 6. ALL MECHANICAL, ELECTRICAL, PLUMBING, SECURITY, UTILITY, CABLE TV, AND TELEPHONE EQUIPMENT SHALL BE INSTALLED SO AS NOT TO BE IN CONFLICT WITH ANY WINDOW, WINDOW SHUTTER, OR SHUTTER PANEL. 7. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL EXTERIOR WALLS. ALL EXTERIOR CONCRETE PATIOS SHALL BE SLOPED DOWN AWAY FROM THE BUILDING AT 1/8" PER FOOT. 30 MIN RATED PARTITION FOR OCCUPANCY SEPARATION 1 HOUR RATED PARTITION 2 HOUR RATED PARTITION NOTES: 1. PROVIDE REQUIRED SEPARATION PROTECTION INCLUDING REQUIRED RATING OF OPENINGS, PROPER PENETRATION PROTECTION, ETC. AT ALL FIRE RESISTANT PARTITIONS. 2. CORRIDOR LOAD BEARING WALLS ARE REQUIRED TO BE PROVIDED WITH 1 HOUR FIRE- RESISTANCE PROTECTION FOR ASSEMBLY AS REQUIRED BY IBC TABLE 601, BUT DOES NOT REQUIRE INCREASE IN OPENING PROTECTION OVER 20 MIN. PER IBC 708.3 EXCEPTION 1 AND TABLE 1020.1, UNLESS OTHERWISE REQUIRED DUE TO NEEDED SEPARATION PROTECTION. 3. IN ADDITION TO WALLS HAVING REQUIRED FIRE-RESISTANCE RATED SEPARATION PROTECTION, ALL EXTERIOR AND INTERIOR LOAD BEARING WALLS AND PRIMARY STRUCTURAL FRAME ELEMENTS ARE REQUIRED TO BE 1-HOUR FIRE RESISTANCE PROTECTED AS REQUIRED BY IBC TABLE 601 AND TABLE 602. SHOWN WITH SOLID HATCH FOR CLARITY.50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.7/16/2021 2:03:14 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 A113a PARTIAL THIRD FLOOR PLANS -BUILDING A The Corner Carmel, IN VWB SWMThe Corner Carmel, IN • 01.18066.00 1685 E. 116th Street, Carmel, IN SCALE: 1/8" = 1'-0" 28 PARTIAL THIRD FLOOR PLAN - BUILDING A SCALE: 1/8" = 1'-0" 25 PARTIAL THIRD FLOOR PLAN - BUILDING A 25/A113a28/A113a06.16.21 Permit Set A 07.15.21 Addendum A