HomeMy WebLinkAboutL110 Site LayoutINJ10 MONLDLDLDE GM PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST IPn MB MON MON MON MON MON MON MON MON MONWWWWWWWWWWWW PPST PPST PPST PPST PPST PPST PPST RB-0 RB-0T H H H H H H H H H CC-TRC WV WV WV WVTPAPAPAPAPAlift station with screenwall, Refer to C series PA10'-0" (2 eq)AABAABA5'-0"5'-8"108'-8" 8'-0"A44'-9" (6 eq)A9'-6"9'-0"6'-0"59'-6" (12 eq) 2'-9" 10'-3" (2 eq)5'-0"6'-0"9'-0"15'-0" (2 eq)ABAA47'-5" (8 eq)A7'-3"15'-9" (2 eq)6'-10"8'-0"4'-4"6'-3"5'-0", typ.11'-7" (2 eq)A47'-5" (7 eq)8'-0"8'-0"8'-0"7'-8"24'-0" (5 eq)33'-4" (7 eq)6'-8"9'-11" (2 eq)A24'-0" (5 eq)A45'-9" (6 eq)8'-0"AB27'-8" (6 eq) 7'-4" (2 eq) 5'-0" 5' - 0 "5'-0"5'-11"A26'-11" (5 eq)48'-0" (10 eq)232'-7" (47 eq)10'-6" (2 eq)59'-5" (12 eq)3'-3"2'-3"10'-6" (2 eq)18'-4" (4 eq)4'-8"A6'-0"8'-0" (2 eq)15'-0" (3 eq)8'-0" (2 eq)179'-9" (26 eq)6'-5"A27'-4" (5 eq)A28'-0" (5 eq)223'-5" (45 eq)5'-0"17'-10"116th St.Rangeline Rd.ProposedBuilding AProposedRetailProposedGarageProposedBuilding DProposedBuilding BProposedBuilding BInterurban TrailR7'-0"6'-0"6'-0"49'-1"5'-0"103'-3"26'-5"41'-1"6'-4"6'-0"7'-10"Client:The CornerCarmel, INSealLRK Project Number: 00.18066.00Project Name:116th Street & RangelineCarmel, INDrawing Name:Drawn By:Checked By:© 2020 LRK Inc.Drawings, written material, and design concepts shall notbe used or reproduced in whole or part in any form orformat without prior written consent of LRK Inc. Do notsacle drawings. Use given dimensions only. If not shown,verify correct dimensions with the Architect. Contractorshall check and verify all dimensions and conditions atjob site.Issues and RevisionsDateIssued / Revised06.16.21Permit SetÉ‘LMAPP5825 Lawton Loop East Drive | Indianapolis, IN 46216317-485-6900 | www.context-design.com0Scale 1" = 30'-0"60'30'15'North1.Dimensions are shown to Face of Curb unless otherwise noted.2.Contractor shall coordinate final joint locations in the field with the LandscapeArchitect. Align to existing conditions when practical, including at building andwall corners, connections to existing work, and to centerlines of doors.3.Space control joints evenly between all bands and expansion joints as shown,unless otherwise dimensioned. Space interim joints equally whenever possible.4.Digital AutoCAD files will be provided to the successful bidder as a courtesy toassist with field layout. The Contractor maintains all responsibility for the use,accuracy, and confirmation of such data.5.All pavement striping shown shall adhere to Specifications. The Contractor shallinclude in their bid any miscellaneous copy, striping, or curb painting that may berequested by the Fire Marshal.6.All disturbed areas not proposed to receive pavements shall be dressed withtopsoil and seeded per Specifications.7.Contractor shall provide and install One (1) Accessible Parking Sign peraccessible parking space indicated in plans. Coordinate final location in the fieldwith Landscape Architect.LAYOUT NOTESL110PEDESTRIAN HARDSCAPE LAYOUT PLANSee Pool Area Enlargement, Sheet L310See Northwest Plaza Enlargement, Sheet L310See Retail Plaza Enlargement, Sheet L310A - Align jointing/change of pavement material to building cornerB - Center pavement band on building cornerC - Align jointing/change of pavement material to wall cornerD- Align jointing/change of pavement material to feature cornerLAYOUT LEGEND