Loading...
HomeMy WebLinkAboutL503 Site DetailsClient:The CornerCarmel, INSealLRK Project Number: 00.18066.00Project Name:116th Street & RangelineCarmel, INDrawing Name:Drawn By:Checked By:© 2020 LRK Inc.Drawings, written material, and design concepts shall notbe used or reproduced in whole or part in any form orformat without prior written consent of LRK Inc. Do notsacle drawings. Use given dimensions only. If not shown,verify correct dimensions with the Architect. Contractorshall check and verify all dimensions and conditions atjob site.Issues and RevisionsDateIssued / Revised06.16.21Permit SetÉ‘LMAPP5825 Lawton Loop East Drive | Indianapolis, IN 46216317-485-6900 | www.context-design.comPOOL COPINGScale: 1"=1'-0"1'-0"112"212"R1 "Adjacent Pavement, Refer to Site Materials Key PlanExpansion Joint, Refer to Detail 2/L500Pre-Cast Stone Pool Coping.Pool Wall, Refer to PoolConsultant Drawings.1/2" Mortar Setting Bed.R7'-0"4" 7"HSS 6" x 14" thick Round Steel pipe ;galvanized, Powder Coated Finish;CATENARY POLES, CABLES, AND STRING LIGHTSScale: 1-1/2" = 1'-0"SS Wire Rope/ Cable &Catenary Light System Referto Specification 32 33 00 forLuminaire Specifications.NOTE:Follow Manufacturer recommendationon hardware selection and installationinstructions.Contractor to design cable sizethrough delegated design. 4,000 psi PIP concreteProvide bracket welded to columnto receive cable hardwareProvide Swageless type SS Turnbuckle at one end.Provide SS Fork Cable hardware at the other end.finish grade3/4" 6"6"4" Cut 6" x 4" handhold. Attach coverto pipe using 516" dia. Type F boltsR1 1/2"5"R2 1 /2 " 6"6"6"6"1 1/2" typ.PLANHSS 6" x 14" thick round Steel pipe ; galvanized,Powder Coated Finish; Close neatly.2"2"(2) 516" dia. Type F bolt6"Ø2"12'-0" total height 1'-4"1'-4" 3'-0"1'-8"(4) 18" x 14" j bolts3" min.#4 rebar @ 12" o.c.BASE PLATE PLAN5"5"1/2"L503SITEDETAILSAXS73831514AXS11551812RMT222614555915AXSPOOL LIFTNot to ScaleSIDE VIEWBACK VIEWTOP VIEWFIRE PITScale: 3/4" = 1'-0"GAS & ELECTRICAL CONNECTIONSAS REQUIRED FOR FIRE PIT SELECTION.FOLLOW MANUFACTURERRECOMMENDATIONS FOR INSTALLATIONFIRE PIT UNIT;REFER TO SPECSCONCRETE PAVEMENT, REFER TOMATERIALS PLANSECTION DETAILNOTES:1.PROVIDE FULLY DETAILED SHOP DRAWING & SYSTEM IGNITION / SHUT-OFF SEQUENCE DIAGRAMFOR OWNER APPROVAL, PRIOR TO CONSTRUCTION.2.PROVIDE THE FOLLOWING:a.UTILITY CONNECTIONS - GAS / ELECTRIC TO CONTROLS & FIRE PIT.b.LOCKABLE & WEATHERPROOF VALVE BOX W/ KEY VALVE & SOLENOID VALVE.c.EMERGENCY SWITCH, TIME SWITCH, & IGNITION SWITCH LOCATED ON 4" x 4" STEEL POST.3.LOCATE EMERGENCY SWITCH & APPLICABLE SIGN(S) PER LOCAL CODE REQUIREMENTS.4.COORDINATE W/ UTILITY / MEP PLANS, AND ALL APPLICABLE TRADES, PRIOR TO CONSTRUCTION.EMERGENCY SHUT OFF: GAS4"x4"X14" TH. GALVANIZED STEEL POST,SOLID TOP, BLACK POWDER COATED FINISH,SEE SPECS.SEE MEP DWGS.12" DIA. CONCRETE FOOTING2'-6"3'-6"3'-0"ADJACENT PLANTING AREA, TYPICALTIMER SWITCHIGNITION SWITCH2'-4"1'-8"EMERGENCY SHUTOFF POST AT GRADENOTES:1. SEE PLAN FOR EMERGENCY SHUT OFF LOCATIONS2. CONTROLS SHALL NOT REQUIRE TIGHT GRASPING,PINCHING, OR TWISTING OF THE WRIST, AND THEOPERABLE FORCE SHALL BE (5) FIVE LBS. MAX.ANCHOR FIRE PIT PERMANUFACTURER SPECIFICATIONS(IF APPLICABLE)1234