HomeMy WebLinkAboutA522 - PARAPET DETAILSBLDG A TRUSS BEARING+880' -11 3/16"----5/4X6 VERTICAL TRIM ALONG THE CENTERLINE OF THE PILASTERMETAL PARAPET COPING WITH DRIP EDGE5/4x10 FIBER CEMENT TRIM3x4 FIBER CEMENT TRIM WITH BEVELED TOP EDGE 5/4x8 FIBER CEMENT TRIMFIBER CEMENT PANELBOARDON 3/4" P.T. WOOD FURRINGEXTERIOR SHEATHINGPARAPET FRAMING, RE: STRUCTURALEXTERIOR SHEATHINGWEATHER BARRIERROOF TRUSSES, RE: STRUCTURAL SELF ADHERED MEMBRANCE FLASHING CONNECTING ROOFING MEMBRANE TO WEATHER BARRIERSINGLE PLY ROOFING MEMBRANE, EXTEND OVER PARAPET WALL1/4" GAP BETWEEN FLASHING AND SIDING -DO NOT PROVIDE SEALANTMETAL FLASHING WITH DRIP EDGE SET IN CONTINUOUS BED OF SEALANTLAP SIDING (7" EXPOSURE)TREATED 2x WOOD BLOCKING8'-8"5/4X6 CORNER BOARD TRIM ON 1X6 TO ALIGN WITH TRIM ABOVE2" RIGID INSULATIONROOF SHEATHINGCOVER BOARDBLDG A TRUSS BEARING+880' -11 3/16"----3'-2 1/2"3'-9 1/2"1/4"METAL PARAPET COPING WITH DRIP EDGEWOOD BLOCKINGSELF ADHERED MEMBRANE FLASHING CONNECTING ROOFING MEMBRANE TO WEATHER BARRIEREXTERIOR SHEATHING1/4" GAP BETWEEN FLASHING AND SIDING -DO NOT PROVIDE SEALANTSINGLE PLY ROOFING MEMBRANE, EXTEND OVER PARAPET WALLPARAPET FRAMING, RE: STRUCTURAL1X2 FIBER CEMENT TRIM1X4 FIBER CEMENT TRIMFIBER CEMENT SOFFIT PANEL2X4 FIBER CEMENT TRIM1X6 FIBER CEMENT TRIMWEATHER BARRIEREXTERIOR SHEATHING2X4 TREATED FRAMINGMETAL FLASHING WITH DRIP EDGE SELF-ADHERED HIGH TEMPERATURE ROOF UNDERLAYMENT ON 1/2" ROOF PLYWOOD. TURN UP WALL 4" MIN.2X TREATED LEDGERS, MECHANICALLY FASTEN TO FRAMING1X8 FIBER CEMENT TRIMFIBER CEMENT LAP SIDINGROOF SHEATHINGCOVER BOARD2" RIGID INSULATIONCONTINUOUS HOOK STRIP2'-0"1:121X6 FIBER CEMENT TRIMFIBER CEMENT PANELCAST STONE BAND PROFILE F, BEYOND2'-7"BLDG A TRUSS BEARING+880' -11 3/16"----FIBER CEMENT LAP SIDING (4" EXPOSURE)EXTERIOR SHEATHINGPARAPET FRAMING, RE: STRUCTURALCOVER BOARD METAL PARAPET COPING WITH DRIP EDGETREATED 2x WOOD BLOCKINGSINGLE PLY ROOFING MEMBRANE, EXTEND OVER PARAPET WALL2" RIGID INSULATIONROOF SHEATHINGLAP SIDING (4" EXPOSURE)EXTERIOR SHEATHINGWEATHER BARRIER2x8 FIBER CEMENT TRIMSELF ADHERED MEMBRANCE FLASHING CONNECTING ROOFING MEMBRANE TO WEATHER BARRIER1/4" GAP BETWEEN FLASHING AND TRIM -DO NOT PROVIDE SEALANT1X2 FIBER CEMENT TRIMMETAL FLASHING WITH DRIP EDGE SET IN CONTINUOUS BED OF SEALANTMETAL FLASHING SELF-ADHERED HIGH TEMPERATURE ROOF UNDERLAYMENT ON 1/2" ROOF PLYWOOD5/4x6 FIBER CEMENT TRIMCONTINUOUS HOOK STRIP1X8 FIBER CEMENT TRIM5/4 x 12 FIBER CEMENT TRIMFIBER CEMENT SOFFIT PANEL1/2"FIBER CEMENT MOULD3'-1 1/2"3'-10 1/2"3:12PILASTER BEYOND50 South B.B. King Blvd.Suite 600Memphis, TN 38103901.521.1440Drawing Name:Client:Drawn By:Checked By:Project Name:SealIssued / RevisedDate#Issues and Revisions©2020 LRK Inc.Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.8/27/2021 11:31:41 AMC:\Revit Projects\18066-Corner Carmel-CENTRAL-19_chaley.rvtLRK Project Number: 01.18066.00A522PARAPET DETAILSThe CornerCarmel, INVWBSWMThe Corner Carmel, IN •01.18066.001685 E. 116th Street, Carmel, INSCALE: 3" = 1'-0"29PARAPET AT PILASTERSCALE: 3" = 1'-0"25FLAT CORNICE -BLDG ABSCALE: 3" = 1'-0"27PARAPET WITH CORNICE -BUILDING AB06.16.21Permit SetA07.15.21Addendum AB08.20.21IFC Set