HomeMy WebLinkAboutA540 - FLASHING DETAILSWEATHER BARRIER EXTERIOR SHEATHING 4" SQUARE DOWNSPOUT METAL SCUPPER PREFINISHED METAL CONDUCTOR HEAD ROOF TRUSS, RE: STRUCTURAL TPO LAPPED OVER AND ADHERED TO SCUPPER FLASHING SCUPPER BASE SLIGHTLY LOWER THAN TOP OF ROOF UNDERLAYMENT TO ALLOW FOR FULL DRAINAGE AT EDGE1 1/2"7"6"1"8"6"SHEET METAL GUTTER FLASHING, J-SHAPE FLASHING SLOPED TO ONE SIDE SELF-ADHERED MEMBRANE COLLAR FLASHING, SHINGLE LAP INTO WEATHER BARRIER A WOOD BLOCKING SQUARED AROUND PERIMETER OF PENETRATION EXTERIOR SHEATHING WEATHER BARRIER FLEXIBLE FLASHING, LAP OVER WEATHER BARRIER AND ONTO FRAMING EXTERIOR SHEATHING WEATHER BARRIER METAL SCUPPER (12" WIDE X 6" HIGH, CLEAR OPENING) FLEXIBLE FLASHING TURNED INTO ROUGH FRAMED OPENING BOTH SIDES FIBER CEMENT LAP-SIDING TPO LAPPED OVER AND ADHERED TO SCUPPER FLASHING FLANGE OF SCUPPER FLEXIBLE FLASHING, LAP OVER WEATHER BARRIER AND ONTO FRAMING 6"ROOF SHEATHING 1" ROOF INSULATION COVER BOARD THRU WALL PENETRATION STEP 6STEP 5 STEP 4STEP #3 STEP #2STEP #1 ROLL SELF-ADHERING FLASHING AROUND PIPE/WIRE AND SEAL TO SELF-ADHERING FLASHING. X"= WIDTH OF PIPE/ WIRE X"= WIDTH OF PIPE/ WIRE 1/4" 3/4"4"1" X"= WIDTH OF PIPE/ WIRE 2"APPLY 1"WIDE SELF-ADHERING FLASHING AROUND PIPE CUT X"w X 1" FLAP IN FLASHING AND FOLD UP APPLY 2ND LAYER OF SELF- ADHERING FLASHING OVER AIR BARRIER AND 1ST LAYER OF FLASHING CUT X"w X 1" FLAP IN FLASHING AND FOLD DOWN ROLL SELF-ADHERING FLASHING OVER TOP OF PIPE. ROLL SELF-ADHERING FLASHING OVER BOTTOM OF PIPE. APPLY 1ST LAYER OF SELF- ADHERING FLASHING OVER AIR BARRIER X" EQ EQ 6" MIN 4"(X)2" 2"4"2"1" EQ EQ 6" MIN X" TPO ROOF MEMBRANE NOTE: VENT STACKS AND OTHER PIPES SHALL HAVE A MINIMUM OF 12 INCHES OF CLEARANCE ON ALL SIDES FROM WALLS, CURBS, AND OTHER PROJECTIONS TO FACILITATE PROPER FLASHING. ROOF DECK THERMAL INSULATION PLUMBING VENT STACK FLASHING MEMBRANE SEALANT (IF REQUIRED BY THE SPECIFIC SYSTEM) SEALANT DRAWBAND 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.7/16/2021 2:23:04 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 A540 FLASHING DETAILS The Corner Carmel, IN Checker AuthorThe Corner Carmel, IN • 01.18066.00 1685 E. 116th Street, Carmel, IN SCALE: 6" = 1'-0" 16 SCUPPER DETAIL SCALE: 6" = 1'-0" 14 SCUPPER OVERFLOW DETAIL SCALE: 3" = 1'-0" 29 PENETRATION FLASHING DETAIL SCALE: 3" = 1'-0" 27 ROOF PENETRATION FLASHING DETAIL 06.16.21 Permit Set A 07.15.21 Addendum A