Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A601 - CONSTRUCTION ASSEMBLIES
CONSTRUCTION ASSEMBLY NOTES A.THE CONTRACTOR SHALL VERIFY ALL ASSEMBLY INFORMATION WITH UNDERWRITERS LABORATORIES, GYPSUM ASSOCIATION, OR OTHER ORGANIZATIONS LISTED IN THE ASSEMBLIES ABOVE TO ENSURE PROPER FIRE RATINGS ARE MAINTAINED. B.WHERE STC (SOUND TRANSMISSION CLASS) RATINGS ARE INDICATED, SOUND-RATED WALL CONSTRUCTION SHALL INCLUDE THE FOLLOWING: 1.CONTINUOUS FLEXIBLE ACOUSTICAL SEALANT AT THE BOTTOM EDGE OF WALLBOARD PANELS. 2.CONTINUOUS FLEXIBLE ACOUSTICAL SEALANT OR JOINT TAPE AND MUD AT WALL INTERSECTIONS. SEAL BETWEEN WALLBOARD AND DISSIMILAR MATERIALS, SUCH AS DOOR OR WINDOW FRAMES. 3.CONTINUOUS ACOUSTICAL SEALANT OR FIRE-CAULK SEALANT (AS REQUIRED BY THE ASSEMBLY LISTING) AT THE TOP EDGE OF THE WALLBOARD. 4.FLEXIBLE ACOUSTICAL SEALANT OR FIRE-CAULK (AS REQUIRED BY THE ASSEMBLY LISTING) AT ALL FULL OR PARTIAL WALL PENETRATIONS AND AROUND OPENINGS, FLUSH-MOUNTED ACCESSORIES, FIRE EXTINGUISHER CABINETS, ELECTRICAL BOXES, ETC. LINE ALL RECESSES FOR BUILT-IN DEVICES SUCH AS FIRE EXTINGUISHER CABINETS, TOILET ACCESSORIES, ETC. WITH WALLBOARD. SEAL ALL JOINTS. 5.COVER ALL KNOCK-OUT PLUGS AND SCREW HOLES IN FLUSH-MOUNTED ELECTRICAL BOXES WITH A MINIMUM 1/16 INCH THICK LAYER OF ACOUSTICAL SEALANT. APPLY TAPE OVER MISSING KNOCK-OUT PLUGS AND COVER WITH MINIMUM 1/8 INCH THICK LAYER OF ACOUSTICAL SEALANT. SOUND-RATED WALLS SHALL BE SEALED AIR-TIGHT AT THE PERIMETER AND AT ALL PARTIAL AND THROUGH-PENETRATIONS. 6.GYPSUM WALLBOARD AND ACOUSTICAL INSULATION IN SOUND-RATED PARTITIONS SHOULD NOT BE INTERRUPTED AT THE INTERSECTIONS WITH NON-SOUND RATED PARTITIONS. FRAMING AND WALLBOARD OF NON-SOUND RATED CONSTRUCTION SHOULD ABUT THE CONTINUOUS WALLBOARD OF THE SOUND-RATED WALL. 7.REFER TO THE GYPSUM ASSOCIATION FIRE RESISTANCE DESIGN MANUAL GA-600 -LATEST EDITION, SECTION III SOUND CONTROL AND TO FIGURE 12 FOR ADDITIONAL DETAILS. FOLLOW GYPSUM ASSOCIATION RECOMMENDATIONS FOR EFFECTIVE SOUND ISOLATION CONSTRUCTION. C.WHERE FIRE-RESISTANT ASSEMBLIES ARE INDICATED, REFER TO THE REFERENCED FIRE-TESTED ASSEMBLY AND PROVIDE THE MATERIALS, BRAND NAMES, PRODUCTS, AND CONSTRUCTION METHODS SPECIFIED THEREIN. D.AT ALL FIRE-RESISTIVE WALLS AND SMOKE BARRIER CONSTRUCTION WHERE A PORTION OF THE CONSTRUCTION IS CONCEALED ABOVE SUSPENDED CEILINGS, STENCIL A NOTE IN 2 INCH HIGH RED LETTERS (OR APPROVED EQUAL) FIRE AND SMOKE BARRIER -PROTECT ALL OPENINGS. NO POINT ALONG THE LENGTH OF THE RATED WALL SHOULD BE MORE THAN 8 FEET FROM A STENCILED NOTE. CONFIRM THE NOTE LANGUAGE AND SPACING REQUIREMENTS WITH THE AUTHORITY HAVING JURISDICTION BEFORE APPLICATION. E.WHERE FLUSH-MOUNTED ELECTRICAL OUTLET BOXES (16 SQUARE INCHES OR LESS) ARE INDICATED LESS THAN 24 INCHES APART ON OPPOSITE SIDES OF FIRE-RESISTIVE CONSTRUCTION, PROVIDE FIRE-RETARDANT PUTTY PADS TO WRAP THE ELECTRICAL BOXES. PUTTY PADS WILL BE PROVIDED TO COMPLY WITH THE BUILDING CODE AND TO CONFORM WITH THE REQUIREMENTS OF THE FIRE-TESTED WALL ASSEMBLY, AND WILL BE UL CLASSIFIED "WALL OPENING PROTECTIVE MATERIAL". F.WHERE RECESSED DEVICES ARE INDICATED IN FIRE-RESISTIVE GYPSUM WALLBOARD CONSTRUCTION, PROVIDE LAYERS OF GYPSUM WALLBOARD BETWEEN THE STUDS, INSIDE THE RECESS -TOP, BOTTOM, BACK, AND SIDES, AS REQUIRED TO MAINTAIN THE FIRE RESISTANCE RATING INDICATED. EXAMPLES OF RECESSED DEVICES INCLUDED ARE TOILET ACCESSORIES, FIRE EXTINGUISHER CABINETS, RECESSED LIGHTS, ETC. UNLESS A RATED FIXTURE IS BEING PROVIDED TO MAINTAIN THE RATING OF THE ASSEMBLY. G.EXTERIOR WALL CONSTRUCTION -ALL PARTIAL PENETRATIONS SHALL BE SEALED. PENETRATIONS THROUGH THE INTERIOR SIDE OF EXTERIOR WALLS SHALL BE SEALED AIR-TIGHT TO PREVENT AIR INFILTRATION. EXAMPLE -ELECTRICAL BOX FOR SWITCH OR OUTLET. PENETRATIONS THROUGH THE EXTERIOR SIDE OF EXTERIOR WALLS SHALL BE SEALED WATER-TIGHT. EXAMPLE -HOSE BIB, CONDUIT, OR PIPE. H.PIPE AND VALVE PENETRATIONS OF WALLBOARD AT BATHTUBS AND SHOWERS SHALL BE SEALED USING SILICONE SEALANT WITH MILDEW-RESISTANT PROPERTIES, SUCH AS GENERAL ELECTRIC CO. "SCS 1701", OR DOW CORNING 786. I.GLASS MAT FACED TILE BACKER BOARD SHALL BE USED AT ALL TUB/SHOWER AREAS. STRUCTURE ABOVE CEILING AS SCHEDULED DOUBLE WOOD TOP PLATE WOOD STUDS, REF. STRUCTURAL FOR SPACING 5/8" GYPSUM WALLBOARD (1 LAYER EACH SIDE) WOOD SILL PLATE FLOORING AS SCHEDULED MARK FIRE RATING UL NUMBER A - - STC RATING - STRUCTURE ABOVE CEILING AS SCHEDULED DOUBLE WOOD TOP PLATE WOOD STUDS, REF. STRUCTURAL FOR SPACING 5/8" TYPE "X" GYPSUM WALLBOARD (1 LAYER EACH SIDE) WOOD SILL PLATE FLOORING AS SCHEDULED MARK FIRE RATING UL NUMBER B 1 HR U305 STC RATING - STRUCTURE ABOVE CEILING AS SCHEDULED PLYWOOD SHEAR PANEL - REFER TO STRUCTURAL SHEAR WALL PLAN AND SCHEDULE FOR LOCATIONS WOOD STUDS, REF. STRUCTURAL FOR SPACING 5/8" TYPE "C" GYPSUM WALLBOARD (1 LAYER EACH SIDE) WOOD SILL PLATE FLOORING AS SCHEDULED DOUBLE WOOD TOP PLATE 1/2" RESILIENT CHANNELS AT 24" O.C VERTICAL ON CORRIDOR SIDE (REFERENCE STRUCTURAL SHEAR WALL PLAN AND SCHEDULE FOR LOCATIONS TO REPLACE CHANNELS WITH PLYWOOD SHEAR PANEL) R-19 SOUND BATT INSULATION MARK FIRE RATING UL NUMBER C 1 HR U311 STC RATING STC-50 MIN STRUCTURE ABOVE CEILING AS SCHEDULED PLYWOOD SHEAR PANEL - REFER TO STRUCTURAL SHEAR WALL PLAN AND SCHEDULE FOR LOCATIONS WOOD STUDS, STAGGER STUDS ON EACH SIDE ON AIR SPACE. REF. STRUCTURAL FOR SPACING 5/8" TYPE "X" GYPSUM WALLBOARD (1 LAYER EACH SIDE) WOOD SILL PLATE FLOORING AS SCHEDULED DOUBLE WOOD TOP PLATE R-19 SOUND BATT INSULATION ACOUSTICAL SEALANT BOTH SIDES AT EACH WALLBOARD LAYER STRUCTURE BELOW 1" AIR SPACE UNITUNIT NOTE: WALL TYPE SHOWN AS COMPLETED WALL CONSTRUCTION. WALL TYPES TAGGED AND DIMENSIONED IN PLANS REFERENCE ONE SIDE OF COMPLETE ASSEMBLY. MARK FIRE RATING UL NUMBER D 1 HR U341 STC RATING - STRUCTURE ABOVE CEILING AS SCHEDULED COLD FORMED METAL FRAMING, REF. STRUCTURAL FOR SPACING 5/8" FIRE-RATED GYPSUM WALLBOARD (1 LAYER EACH SIDE) FLOORING AS SCHEDULED 2" THICK MINERAL WOOL BATTS MARK FIRE RATING UL NUMBER H - - STC RATING - STRUCTURE ABOVE CEILING AS SCHEDULED DOUBLE WOOD TOP PLATE WOOD STUDS, REF. STRUCTURAL FOR SPACING 5/8" TYPE "X" GYPSUM WALLBOARD WOOD SILL PLATE FLOORING AS SCHEDULED WEATHER BARRIER OVER 5/8" OSB SHEATHING EXTERIOR FINISH: MASONRY VENEER OR FIBER CEMENT LAP SIDING/PANEL, REF. ELEVATIONS RATED FOR FIRE FROM INTERIOR SIDE ONLY MARK FIRE RATING UL NUMBER G 1 HR U356 STC RATING - R-19 THERMAL BATT INSULATION MARK FIRE RATING UL NUMBER E 2 HR U347 STC RATING STRUCTURE ABOVE CEILING AS SCHEDULED WOOD STUDS, STAGGER STUDS ON EACH SIDE ON AIR SPACE. REF. STRUCTURAL FOR SPACING 5/8" TYPE "X" GYPSUM WALLBOARD (1 LAYER EACH SIDE) WOOD SILL PLATE FLOORING AS SCHEDULED DOUBLE WOOD TOP PLATE 3" R-19 SOUND BATT INSULATION ACOUSTICAL SEALANT BOTH SIDES AT EACH WALLBOARD LAYER STRUCTURE BELOW 4" AIR SPACE UNITUNIT METAL CLIPS H SHAPED STEEL STUD 2 LAYERS OF 1" DENSGLASS SHAFTLINER PANELS CONTINUOUS THROUGH ALL FLOOR ASSEMBLY FIRESTOPPING STC-50 MIN STRUCTURE ABOVE CEILING AS SCHEDULED 5/8" TYPE "C" GYPSUM BOARD OVER 5/8" SOUND- RATED GYPSUM BOARD WOOD STUDS, REF. STRUCTURAL FOR SPACING 5/8" TYPE "C" GYPSUM WALLBOARD (2 LAYERS) WOOD SILL PLATE FLOORING AS SCHEDULED DOUBLE WOOD TOP PLATE R-19 SOUND BATT INSULATION MARK FIRE RATING UL NUMBER J 2 HR U301 STC RATING - CONCRETE MASONRY UNIT MARK FIRE RATING UL NUMBER F1 2 HR U905 STC RATING STC-50 MIN WOOD FRAMING FOR REFERENCE ONLY (NOT PART OF RATED ASSEMBLY) SHAFT F2 - - - UNIT OR CORRIDOR STRUCTURE ABOVE CEILING AS SCHEDULED WOOD STUDS, STAGGER STUDS ON EACH SIDE ON AIR SPACE. REF. STRUCTURAL FOR SPACING 5/8" TYPE "X" GYPSUM WALLBOARD (1 LAYER EACH SIDE) WOOD SILL PLATE FLOORING AS SCHEDULED DOUBLE WOOD TOP PLATE ACOUSTICAL SEALANT BOTH SIDES AT EACH WALLBOARD LAYER STRUCTURE BELOW AIR SPACE VARIES STAIRSTAIR MARK FIRE RATING UL NUMBER K - - STC RATING - A CAST-IN-PLACE CONCRETE REF. STRUCTURAL FOR THICKNESS FLOORING AS SCHEDULED MARK FIRE RATING UL NUMBER P - - STC RATING - A STRUCTURE ABOVE CEILING AS SCHEDULED COLD FORMED METAL FRAMING, REF. STRUCTURAL FOR SIZE AND SPACING 5/8" FIRE-RATED GYPSUM WALLBOARD FLOORING AS SCHEDULED R-19 KRAFT FACED BATT INSULATION WITH AIR BARRIER ON INTERIOR SIDE MARK FIRE RATING UL NUMBER L 1 HR. U425 STC RATING - COLD FORMED METAL FRAMING, DOUBLE HEAD SLIP TRACK EXTERIOR FINISH: MASONRY VENEER OR FIBER CEMENT LAP SIDING/PANEL, REF. ELEVATIONS WEATHER BARRIER OVER 5/8" GYPSUM SHEATHING COLD FORMED METAL FRAMING, STUD SILL TRACK FOAM SILL SEALER BELOW BOTTOM TRACK AT FLOOR STRUCTURE A 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.7/16/2021 2:23:11 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 A601 CONSTRUCTION ASSEMBLIES The Corner Carmel, IN VWB RCHThe Corner Carmel, IN • 01.18066.00 1685 E. 116th Street, Carmel, IN A PARTITION TYPE A B PARTITION TYPE B C PARTITION TYPE C - CORRIDOR D PARTITION TYPE D - UNIT DEMISING H PARTITION TYPE HGPARTITION TYPE G - EXTERIOR WALLEPARTITION TYPE E - FIRE WALL J PARTITION TYPE J - VERTICAL SHAFT F PARTITION TYPE F - VERTICAL SHAFT K PARTITION TYPE K P PARTITION TYPE P LOAD BEARING LOAD BEARING LOAD BEARING LOAD BEARING LOAD BEARING LOAD BEARING L PARTITION TYPE L 06.16.21 Permit Set A 07.15.21 Addendum A