A602 - CONSTRUCTION ASSEMBLIES
3/4" GYPCRETE TOPPING 1/8" SOUND CONTROL MAT 3/4" NOM. PLYWOOD OR OSB DECKING, REF. STRUCTURAL OPEN WEB WOOD FLOOR TRUSSES, REF. STRUCTURAL R-38 SOUND BATT INSULATION 5/8" TYPE 'X' GYPSUM WALLBOARD ON RESILIENT CHANNELS NUMBER TRUSS SIZE FIRE RATING UL NUMBER 1A 18" 1 HR. L592 STC RATING / IIC RATING 50 (MIN.) / 50 (MIN.) A A POST TENSION CONCRETE FLOOR SLAB NUMBER THICKNESS FIRE RATING UL NUMBER 3 HR. - STC RATING / IIC RATING 50 MIN. / 50 MIN.2 14" FINISH CEILING WITH MINIMUM 50 STC RATING REQUIRED BETWEEN RESIDENTIAL UNITS AND RETAIL TENANT SPACE (FOR SUSPENDED CEILING, SOUND ISOLATION HANGERS ARE REQUIRED.) AUNIT FLOOR FINISH OVER SOUND CONTROL MAT ROOFING SYSTEM: OPTION #1:SINGLE PLY MEMBRANE OVER COVER BOARD ON PLYWOOD ROOF DECK OPTION #2:ASPHALT SHINGLES (OMIT RIGID INSULATION) OPTION #3: STANDING SEAM METAL ROOFING 3/4" NOM. PLYWOOD OR OSB DECKING, REF. STRUCTURAL OPEN WEB WOOD FLOOR TRUSSES, REF. STRUCTURAL SOUND INSULATION 5/8" TYPE 'X' GYPSUM WALLBOARD ON RESILIENT CHANNELS NUMBER TRUSS SIZE FIRE RATING UL NUMBER 3 PITCHED 1 HR. P522 IIC RATING - VARIES 12 2" RIGID INSULATION A A ROOFING SYSTEM: OPTION #1:SINGLE PLY MEMBRANE OVER COVER BOARD ON PLYWOOD ROOF DECK OPTION #2:ASPHALT SHINGLES (OMIT RIGID INSULATION) OPTION #3: STANDING SEAM METAL ROOFING 3/4" NOM. PLYWOOD OR OSB DECKING, REF. STRUCTURAL OPEN WEB WOOD FLOOR TRUSSES, REF. STRUCTURAL SOUND INSULATION 5/8" TYPE 'X' GYPSUM WALLBOARD NUMBER TRUSS SIZE FIRE RATING UL NUMBER 4 PITCHED 2 HR. P571 IIC RATING - VARIES 12 RESILIENT CHANNELS 2" RIGID INSULATION A A 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.7/16/2021 2:23:14 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 A602 CONSTRUCTION ASSEMBLIES The Corner Carmel, IN VWB DSPThe Corner Carmel, IN • 01.18066.00 1685 E. 116th Street, Carmel, IN 1 FLOOR / CEILING TYPE 1 2 FLOOR / CEILING TYPE 2 3 CEILING / ROOF TYPE 34CEILING / ROOF TYPE 4 06.16.21 Permit Set A 07.15.21 Addendum A