Loading...
HomeMy WebLinkAboutA612 - CONSTRUCTION ASSEMBLIES AND GARAGE FINISH SCHEDULECONSTRUCTION ASSEMBLY NOTESFINISH LEGENDA.THE CONTRACTOR SHALL VERIFY ALL ASSEMBLY INFORMATION WITH UNDERWRITERS LABORATORIES, GYPSUM ASSOCIATION, OR OTHER ORGANIZATIONS LISTED IN THE ASSEMBLIES ABOVE TO ENSURE PROPER FIRE RATINGS ARE MAINTAINED.B.WHERE STC (SOUND TRANSMISSION CLASS) RATINGS ARE INDICATED, SOUND-RATED WALL CONSTRUCTION SHALL INCLUDE THE FOLLOWING:1.CONTINUOUS FLEXIBLE ACOUSTICAL SEALANT AT THE BOTTOM EDGE OF WALLBOARD PANELS.2.CONTINUOUS FLEXIBLE ACOUSTICAL SEALANT OR JOINT TAPE AND MUD AT WALL INTERSECTIONS. SEAL BETWEEN WALLBOARD AND DISSIMILAR MATERIALS, SUCH AS DOOR OR WINDOW FRAMES. 3.CONTINUOUS ACOUSTICAL SEALANT OR FIRE-CAULK SEALANT (AS REQUIRED BY THE ASSEMBLY LISTING) AT THE TOP EDGE OF THE WALLBOARD. 4.FLEXIBLE ACOUSTICAL SEALANT OR FIRE-CAULK (AS REQUIRED BY THE ASSEMBLY LISTING) AT ALL FULL OR PARTIAL WALL PENETRATIONS AND AROUND OPENINGS, FLUSH-MOUNTED ACCESSORIES, FIRE EXTINGUISHER CABINETS, ELECTRICAL BOXES, ETC. LINE ALL RECESSES FOR BUILT-IN DEVICES SUCH AS FIRE EXTINGUISHER CABINETS, TOILET ACCESSORIES, ETC. WITH WALLBOARD. SEAL ALL JOINTS. 5.COVER ALL KNOCK-OUT PLUGS AND SCREW HOLES IN FLUSH-MOUNTED ELECTRICAL BOXES WITH A MINIMUM 1/16 INCH THICK LAYER OF ACOUSTICAL SEALANT. APPLY TAPE OVER MISSING KNOCK-OUT PLUGS AND COVER WITH MINIMUM 1/8 INCH THICK LAYER OF ACOUSTICAL SEALANT. SOUND-RATED WALLS SHALL BE SEALED AIR-TIGHT AT THE PERIMETER AND AT ALL PARTIAL AND THROUGH-PENETRATIONS. 6.GYPSUM WALLBOARD AND ACOUSTICAL INSULATION IN SOUND-RATED PARTITIONS SHOULD NOT BE INTERRUPTED AT THE INTERSECTIONS WITH NON-SOUND RATED PARTITIONS. FRAMING AND WALLBOARD OF NON-SOUND RATED CONSTRUCTION SHOULD ABUT THE CONTINUOUS WALLBOARD OF THE SOUND-RATED WALL. 7.REFER TO THE GYPSUM ASSOCIATION FIRE RESISTANCE DESIGN MANUAL GA-600 -LATEST EDITION, SECTION III SOUND CONTROL AND TO FIGURE 12 FOR ADDITIONAL DETAILS. FOLLOW GYPSUM ASSOCIATION RECOMMENDATIONS FOR EFFECTIVE SOUND ISOLATION CONSTRUCTION.C.WHERE FIRE-RESISTANT ASSEMBLIES ARE INDICATED, REFER TO THE REFERENCED FIRE-TESTED ASSEMBLY AND PROVIDE THE MATERIALS, BRAND NAMES, PRODUCTS, AND CONSTRUCTION METHODS SPECIFIED THEREIN. D.AT ALL FIRE-RESISTIVE WALLS AND SMOKE BARRIER CONSTRUCTION WHERE A PORTION OF THE CONSTRUCTION IS CONCEALED ABOVE SUSPENDED CEILINGS, STENCIL A NOTE IN 2 INCH HIGH RED LETTERS (OR APPROVED EQUAL) FIRE AND SMOKE BARRIER -PROTECT ALL OPENINGS. NO POINT ALONG THE LENGTH OF THE RATED WALL SHOULD BE MORE THAN 8 FEET FROM A STENCILED NOTE. CONFIRM THE NOTE LANGUAGE AND SPACING REQUIREMENTS WITH THE AUTHORITY HAVING JURISDICTION BEFORE APPLICATION. E.WHERE FLUSH-MOUNTED ELECTRICAL OUTLET BOXES (16 SQUARE INCHES OR LESS) ARE INDICATED LESS THAN 24 INCHES APART ON OPPOSITE SIDES OF FIRE-RESISTIVE CONSTRUCTION, PROVIDE FIRE-RETARDANT PUTTY PADS TO WRAP THE ELECTRICAL BOXES. PUTTY PADS WILL BE PROVIDED TO COMPLY WITH THE BUILDING CODE AND TO CONFORM WITH THE REQUIREMENTS OF THE FIRE-TESTED WALL ASSEMBLY, AND WILL BE UL CLASSIFIED "WALL OPENING PROTECTIVE MATERIAL". F.WHERE RECESSED DEVICES ARE INDICATED IN FIRE-RESISTIVE GYPSUM WALLBOARD CONSTRUCTION, PROVIDE LAYERS OF GYPSUM WALLBOARD BETWEEN THE STUDS, INSIDE THE RECESS -TOP, BOTTOM, BACK, AND SIDES, AS REQUIRED TO MAINTAIN THE FIRE RESISTANCE RATING INDICATED. EXAMPLES OF RECESSED DEVICES INCLUDED ARE TOILET ACCESSORIES, FIRE EXTINGUISHER CABINETS, RECESSED LIGHTS, ETC. UNLESS A RATED FIXTURE IS BEING PROVIDED TO MAINTAIN THE RATING OF THE ASSEMBLY.G.EXTERIOR WALL CONSTRUCTION -ALL PARTIAL PENETRATIONS SHALL BE SEALED. PENETRATIONS THROUGH THE INTERIOR SIDE OF EXTERIOR WALLS SHALL BE SEALED AIR-TIGHT TO PREVENT AIR INFILTRATION. EXAMPLE -ELECTRICAL BOX FOR SWITCH OR OUTLET. PENETRATIONS THROUGH THE EXTERIOR SIDE OF EXTERIOR WALLS SHALL BE SEALED WATER-TIGHT. EXAMPLE -HOSE BIB, CONDUIT, OR PIPE. H.PIPE AND VALVE PENETRATIONS OF WALLBOARD AT BATHTUBS AND SHOWERS SHALL BE SEALED USING SILICONE SEALANT WITH MILDEW-RESISTANT PROPERTIES, SUCH AS GENERAL ELECTRIC CO. "SCS 1701", OR DOW CORNING 786.I.GLASS MAT FACED TILE BACKER BOARD SHALL BE USED AT ALL TUB/SHOWER AREAS.8" NOMINAL CONCRETE MASONRY UNITFLOORING AS SCHEDULEDMARKFIRE RATINGUL NUMBERF2 HRU905STC RATING-CAST-IN-PLACE CONCRETEREF. STRUCTURAL FOR THICKNESSFLOORING AS SCHEDULEDMARKFIRE RATINGUL NUMBERP--STC RATING-STRUCTURE ABOVECEILING AS SCHEDULED6" COLD FORMED METAL FRAMING,REF. STRUCTURAL FOR SPACING5/8" GYPSUM WALLBOARD (1 LAYER EACH SIDE)FLOORING AS SCHEDULEDMARKFIRE RATINGUL NUMBERF--STC RATING-CAST-IN-PLACE CONCRETENUMBERTHICKNESSFIRE RATINGUL NUMBER--STC RATING-38"SYMBOLMATERIAL/FINISHCOLORSTYLEP-1P-2WC-8BENJAMIN MOOREHD WALLSHDW-SPILL-01PACIFICOC-25CLOUD COVERFLATBENJAMIN MOOREHC-105ROCKPORT GRAYFLATBACKING: TYPE II, CLASS A, NON-WOVEN50 South B.B. King Blvd.Suite 600Memphis, TN 38103901.521.1440Drawing Name:Client:Drawn By:Checked By:Project Name:SealIssued / RevisedDate#Issues and Revisions©2020 LRK Inc.Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.6/2/2021 5:22:44 PMC:\Revit Projects\18066-Corner Carmel-CENTRAL-19_chaley.rvtLRK Project Number: 01.18066.00A612CONSTRUCTIONASSEMBLIES AND GARAGEFINISH SCHEDULEThe CornerCarmel, INCheckerAuthor116th Street & RangelineCarmel, INThe Corner Carmel, IN •01.18066.00FPARTITION TYPE FPPARTITION TYPE PHPARTITION TYPE H3FLOOR / CEILING TYPE 3GARAGE FINISH SCHEDULEROOM NO.ROOM NAMEROOM FINISHESFLOOR FINISHBASE FINISHWALL FINISHCEILING FINISHG102RETAIL TRASHUNSEALED CONC.-P-2P-1G103BIKE STORAGESEALED CONC.-P-2P-1G104MAINTENANCESEALED CONC.-P-2P-1G105MAINT. OFFICESEALED CONC.-P-2P-1G106MECH.UNSEALED CONC.-P-2P-1G107RETAIL TRASHUNSEALED CONC.-P-2P-1G108RESTROOMSEALED CONC.-P-2P-1G109STORAGEUNFINISHED-UNFINISHEDUNFINISHEDGrand total: 806.02.21Permit Set - Garage