Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A172 - UNIT PLAN B2
UNIT ACCESSIBILITY NOTES UNIT NOTES UNIT PLAN LEGEND ACCESSIBILITY PLAN KEYNOTES 20'-0"BEDROOM 2 LIVING BEDROOM 1 KITCHEN BATH 2 BATH 1 CLOSET 1 CLOSET 2 35'-7"36'-0" A172 3 5 A172 11 A172 18 12ACCENTA172 6 U1 U8 U2 U2 U2 U3 U8 U2 U2 U10 U2 COATPANTRYBALCONY A1724 5 1/2"5'-4 1/2" 13'-5"5 1/2" 5'-8 1/2" 7'-1"2'-6" 1'-8" 5'-0" 7'-4" 5'-10" 2'-6"7'-6" 5'-10" 7'-6"5 1/2"13'-3" 5'-6 1/2"5 1/2"11" 2'-0 1/2"3'-7 1/2" 1'-8 1/2"11'-1" 3'-10" 2'-1" 3'-7 1/2" 5'-1 1/4"5 1/4"2'-6 3/4" 1'-2 1/2" 6'-1" 3'-1"7'-3 1/4"3 1/4"5'-1 1/4"7'-3 3/4"3'-7"3'-8"30'-9" D G C D A U14 B B BB MECH W D 26 A172 14 A172 20 45°6'-9"7'-3"CL3'-6"3'-3"CL3'-9"3'-6" B B B B BA A 17 2S/2R1S/1R 4S1S/1R2S/2R 1S/1RTB18TPHTB24 TB24TPH TB18 A A BEARING WALLS 1-HR 01 02 0202 02 02 02 13 03 11 05 05 08 HATCHED AREA INDICATES ACCESSIBLE ROUTE THROUGH UNIT CL20 3/4"18"10 09 03 08 CLR. 3'-5 87/128" CL 18 3/4"18"OPTION A BATH OPTION A BATH1. ALL DIMENSIONS ON UNIT PLANS ARE TO OUTSIDE FACE OF STUD UNLESS NOTED OTHERWISE. STUDS NOT DIMENSIONED ARE 2x4 WOOD STUDS TYPICAL UNLESS NOTED OTHERWISE. 2. ALL FINISH DIMENSIONS ARE BASED ON 5/8" GYPSUM BOARD AT ALL INTERIOR BEARING AND NON-BEARING PARTITIONS. ALL INTERIOR ELEVATION ARE DRAWN ASSUMING FINISH FACE OF GYPSUM BOARD, U.N.O. 3. KITCHEN BASE CABINETS ARE 24" DEEP AND BATH BASE CABINETS ARE 21" DEEP, TYP. 4. VERIFY EXACT DIMENSIONS REQUIRED TO INSTALL HVAC AND WATER HEATING EQUIPMENT WITH MANUFACTURER BEFORE BUILDING ENCLOSURE WALLS AND FURR DOWNS. 5. VERIFY FRAMING OPENING DIMENSIONS SHOWN FOR TUBS AND SHOWERS WITH ACTUAL TUB AND SHOWER SUPPLIED. ADJUST AS REQUIRED. 6. MOISTURE AND MOLD RESISTANT BOARD SHALL BE USED AT ALL TUB/SHOWER AREAS. 7. REFERENCE UNIT FINISH SCHEDULE FOR ALL INTERIOR UNIT WALLS, CEILINGS, FLOORS, AND BASE TRIM. FOR MECHANICAL CLOSETS THAT ARE USED AS A PLENUM, MATERIALS WITHIN THE CLOSET SHALL BE NONCONBUSTIBLE AND CONFORM TO IMC SECTION 602. 8. REFER TO PROJECT TABULATION FOR PROJECT SQUARE FOOTAGE INFORMATION. ALL WORK AND CONSTRUCTION SHALL MEET OR EXCEED ALL APPLICABLE CODES. 9. MOUNTING HEIGHT FOR TOWEL BAR INSIDE SHOWER TUBS OR ABOVE TOILET IS 5'-0" A.F.F., OTHERWISE MOUNTING HEIGHT FOR TOWEL BAR IS 4'-0" A.F.F. 10. MOUNTING HEIGHT FOR TPH IS 18" A.F.F. 11. PROVIDE FINISH PANELS AT ALL EXPOSED END CONDITIONS OF CABINETS. 12. INSULATE ALL PLUMBING RISERS IN WALL WITH BATT INSULATION. 13. CLOSET SHELVING: 1. 1S/1R IS ONE SHELF MOUNTED AT 68" A.F.F., WITH INTEGRAL ROD. 2. 2S/2R IS TWO SHELVES AT 42" AND 82" A.F.F., WITH INTEGRAL ROD AT EACH SHELF. 3. 4S IS FOUR SHELVES AT 16", 32", 48", AND 64" A.F.F. 4. 5S IS FIVE SHELVES AT 16", 32", 48", 64", AND 80" A.F.F. 14. BATHROOM ACCESSORIES: 1. TR : TOWEL RING 2. RB : ROBE HOOK 3. TPH : TOILET PAPER ROLL HOLDER 4. TB18, TB24 : TOWEL BAR (NUMBER INDICATES LENGTH IN INCHES) 15. PROVIDE INTEGRAL TRANSITIONS AT ALL FLOORING FINISH CHANGES. 16. IN CLOSETS AND ROOMS WHERE FLOOR FINISH IS NOT INDICATED OR SCHEDULED, CONTINUE FLOOR FINISH FROM ADJACENT ROOM. 30 MIN RATED PARTITION FOR OCCUPANCY SEPARATION 1 HOUR RATED PARTITION 2 HOUR RATED PARTITION NOTES: 1. PROVIDE REQUIRED SEPARATION PROTECTION INCLUDING REQUIRED RATING OF OPENINGS, PROPER PENETRATION PROTECTION, ETC. AT ALL FIRE RESISTANT PARTITIONS. 2. CORRIDOR LOAD BEARING WALLS ARE REQUIRED TO BE PROVIDED WITH 1 HOUR FIRE-RESISTANCE PROTECTION FOR ASSEMBLY AS REQUIRED BY IBC TABLE 601, BUT DOES NOT REQUIRE INCREASE IN OPENING PROTECTION OVER 20 MIN. PER IBC 708.3 EXCEPTION 1 AND TABLE 1020.1, UNLESS OTHERWISE REQUIRED DUE TO NEEDED SEPARATION PROTECTION. 3. IN ADDITION TO WALLS HAVING REQUIRED FIRE-RESISTANCE RATED SEPARATION PROTECTION, ALL EXTERIOR AND INTERIOR LOAD BEARING WALLS AND PRIMARY STRUCTURAL FRAME ELEMENTS ARE REQUIRED TO BE 1-HOUR FIRE RESISTANCE PROTECTED AS REQUIRED BY IBC TABLE 601 AND TABLE 602. SHOWN WITH SOLID HATCH FOR CLARITY. GENERAL THIS PROJECT SHALL MEET ALL CRITERIA OF SECTION 1104 TYPE B DWELLING UNITS PROVIDED BY ICC/ANSI A117.1-2009, THE FOLLOWING IS A SUMMARY OF THOSE GUIDELINES. 1. THE ACCESSIBLE PRIMARY ENTRANCE SHALL BE ON AN ACCESSIBLE ROUTE FROM PUBLIC AND COMMON AREAS. 2. PROVIDE AN ACCESSIBLE ROUTE TO ALL SPACES WITHIN UNIT. 3. THE PRIMARY ENTRANCE DOOR TO THE UNIT SHALL COMPLY WITH SECTION 404, EXCEPT THAT MANUVERING CLEARANCES SHALL NOT BE REQUIRED ON THE UNIT SIDE. ALL OTHER DOORWAYS WITHIN THE UNIT INTENDED FOR USER PASSAGE SHALL HAVE A CLEAR OPENING OF 31 3/4" MINIMUM IN THE OPEN POSITION. 4. MAXIMUM THRESHOLD HEIGHT SHALL NOT BE GREATER THAN 1/2". 5. PROVIDE LIGHTING CONTROLS, ELECTRICAL SWITCHES AND RECEPTACLES, ENVIRONMENTAL CONTROLS, APPLIANCE CONTROLS, OPERATING HARDWARE FOR OPERABLE WINDOWS, PLUMBING FIXTURES CONTROLS, AND USER CONTROLS FOR SECURITY OR INTERCOM SYSTEMS THAT COMPLY WITH ANSI SECTION 309. TOILET AND BATHING FACILITIES: GENERAL: 1. THE DOOR SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE FOR ANY FIXTURE UNLESS A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE DOOR SWING. CLEAR FLOOR SPACE AT FIXTURES SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCES COMPLYING WITH SECTION 306. CLEAR FLOOR SPACES SHALL BE PERMITTED TO OVERLAP. 2. REINFORCEMENT SHALL BE PROVIDED FOR THE FUTURE INSTALLATION OF GRAB BARS AND SHOWER SEATS. SEE DRAWING 5/A150 FOR TYPICAL LOCATIONS. KITCHENS 1. PROVIDE A MINIMUM OF 40" CLEAR BETWEEN ALL OPPOSING BASE CABINETS, COUNTER TOPS, APPLIANCES AND/OR WALLS WITHIN KITCHEN WORK AREAS AT ALL KITCHENS. 2. KITCHEN SINK: PROVIDE A CLEAR FLOOR SPACE CENTERED ON THE FIXTURE FOR PARALLEL APPROACH. 3. DISHWASHER: PROVIDE A CLEAR FLOOR SPACE POSITIONED FOR A PARALLEL OR FORWARD APPROACH TO THE DISHWASHER. THE CLEAR FLOOR SPACE SHALL BE POSITIONED BEYOND THE SWING OF THE DISHWASHER DOOR. 4. OVEN (RANGE): PROVIDE A CLEAR FLOOR SPACE CENTERED ON THE APPLIANCE FOR A PARALLEL OR FORWARD APPROACH. 5. REFRIGERATOR/FREEZER: PROVIDE A CLEAR FLOOR SPACE POSITIONED FOR PARALLEL OR FORWARD APPROACH. WHEN THE CLEAR FLOOR SPACE IS POSITIONED FOR A PARALLEL APPROACH, THE CENTERLINE OF THE CLEAR FLOOR SPACE SHALL BE OFFSET 24 INCHES MAXIMUM FROM THE CENTERLINE OF THE APPLIANCE. LAUNDRY 1. ROOMS OR CLOSETS SHALL ALLOW FOR A 30"x48" CLEAR FLOOR SPACE POSITIONED FOR PARALLEL APPROACH AND CENTERED ON EACH APPLIANCE AND IS ALLOWED TO BE OFFSET A MAXIMUM 24 INCHES FOR EITHER A FORWARD OR PARALLEL APPROACH FOR A FRONT LOADING MACHINE. NOTE: ON ACCESSIBILITY PLANS, ALL DIMENSIONS GIVEN ARE CLEAR FINISH SPACES. 01 ACCESSIBLE DOOR - SEE 3/A150 FOR CLEARANCE REQUIREMENTS USABLE DOOR - SEE 3/A150 FOR REQUIREMENTS 30"x48" CLEAR FLOOR SPACE CENTERED ON APPLIANCE/FIXTURE - PARALLEL APPROACH SEE 1/A150 AND 4/A150 FOR CLEARANCE REQUIREMENTS 30"x48" CLEAR FLOOR SPACE CENTERED ON APPLIANCE/FIXTURE - PERPENDICULAR APPROACH SEE 1/A150 FOR CLEARANCE REQUIREMENTS 48"x56" CLEAR FLOOR SPACE AT WATER CLOSET - SIDE APPROACH SEE 4/A150 FOR CLEARANCE REQUIREMENTS 48"x66" CLEAR FLOOR SPACE AT WATER CLOSET - FORWARD AND SIDE APPROACH SEE 4/A150 FOR CLEARANCE REQUIREMENTS 30"x48" CLEAR FLOOR SPACE AT TUB/SHOWER SEE 4/A150 FOR CLEARANCE REQUIREMENTS 48"x60" CLEAR FLOOR SPACE FOR FORWARD APPROACH OR 30"x60" CLEAR FLOOR SPACE FOR PARAPELL APPROACH AT TUB/SHOWER, SEE 4/A150 FOR CLEARANCE REQUIREMENTS DENOTES AREA TO RECEIVE CONTINUOUS 2x8 BLOCKING FOR FUTURE GRAB BARS SEE 5/A150 FOR REQUIREMENTS 30"X48" CLEAR FLOOR SPACE CENTERED ON COOKTOP WITH 30"X48" OFFSET CLEAR FLOOR SPACE ON OVEN - PARALLEL APPROACH, SEE 1/A150 FOR CLEARANCE REQUIREMENTS 30"X48" OFFSET CLEAR FLOOR SPACE ON DISHWASHER - PARALLEL APPROACH, SEE 1/A150 FOR CLEARANCE REQUIREMENTS 30"X48" OFFSET CLEAR FLOOR SPACE ON FRONT LOAD WASHER/DRYER - PARALLEL APPROACH, SEE 2/A150 FOR CLEARANCE REQUIREMENTS 30"X48" OFFSET CLEAR FLOOR SPACE ON REFRIGERATOR WITH TOP FREEZER - PARALLEL APPROACH, SEE 1/A150 FOR CLEARANCE REQUIREMENTS 02 03 04 05 06 07 08 09 10 11 12 13 3'-6"1'-6"3'-0"FILLER 24"33"21"FILLER FILLER 24"33"15"2" FILLER DW TILE BACKSPLASH 9'-0"2" FILLER 18" D.B. 18"3'-0"1'-6"3'-6"2" FILLER 15"27"36" REF.2'-8"CL 30" HOLD 18"21 3/4"33" D.B. 15"1" FILLER6'-0"7'-4"TUB 1'-8"1'-8"2'-8"CL 30" HOLD 18"19 3/4"33" D.B. 12"1" FILLER 1'-8"1'-8"7'-4"6'-0"7'-0"5'-0"9'-0"V.I.F. ALIGN PER PLAN EQEQEQEQEQEQEQEQ NOTE: NO FIRE ALARM TO BE LOCATED ON ACCENT WALL. 1x4 WOOD TRIM RAILS AND STILES, PAINTED 2" FILLER15"30"15"2" FILLER 3'-0"1'-6"3'-6"FILLER18"30"18"FILLER 9'-0"MICRO RANGE 2" 24"FILLER 33"2" 24"FILLER 1'-0"1 1/2"COUNTER2'-1 3/4"COUNTER 3'-7"CO UNTER2'-10 1/4"COUNTER3'-7"CO UNTER4'-10 3/4" 1'-0"1 1/2" 33" PANEL FILLER24" PANEL FILLER 24"3'-0"3'-0"1/4x1 WOOD TRIM, PTD TO MATCH ISLAND WALL A CL EQ EQCLEQEQ CLEQ EQ CLEQEQEQ EQ EQ EQ EQEQEQEQEQ EQ EQ EQ EQ 3'-0"EQ EQ EQEQEQEQEQ EQ EQ EQ EQEQEQ EQ EQEQ3'-10"4'-0"3'-0"4'-6"2'-9"2'-4" 10 1/8"3'-4"1'-1 5/8"3'-4"6'-8"3'-4"TILE SURROUND (TYP. THREE SIDES OF TUB) 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.7/16/2021 2:21:35 PMC:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 A172 UNIT PLAN B2 The Corner Carmel, IN VWB SWMThe Corner Carmel, IN • 01.18066.00 1685 E. 116th Street, Carmel, IN SCALE: 1/4" = 1'-0" 29 UNIT PLAN - B2 SCALE: 1/4" = 1'-0" 27 UNIT B2 - ANSI B ACCESSIBILITY DIAGRAM SCALE: 3/8" = 1'-0" 3 INT. ELEV. - KITCHEN SCALE: 3/8" = 1'-0" 5 INT. ELEV. - KITCHEN SCALE: 3/8" = 1'-0" 18 INTERIOR ELEVATION - BATH 2 SCALE: 3/8" = 1'-0" 11 INT. ELEVATION - BATH 1 SCALE: 3/8" = 1'-0" 12 INT. ELEVATION - BATH 1 SCALE: 3/8" = 1'-0" 6 INT. ELEVATION - ACCENT SCALE: 3/8" = 1'-0" 4 INT. ELEV. - KITCHEN SCALE: 3/8" = 1'-0" 26 KITCHEN ISLAND PLAN SCALE: 3/8" = 1'-0" 14 INTERIOR ELEVATION - KIT. ISL. SCALE: 3/8" = 1'-0" 20 INTERIOR ELEVATION - KIT. ISL. SCALE: 1/4" = 1'-0" 15 REFLECTED CEILING PLAN - UNIT B2 SCALE: 3/8" = 1'-0" 17 INT. ELEVATION - BATH 2 06.16.21 Permit Set A 07.15.21 Addendum A