HomeMy WebLinkAboutA350 - BLDG A - RATED WALL SECTIONSBLDG A L 05 +871' -10 1/16" BLDG A TRUSS BEARING +880' -11 3/16" BLDG A L 02 +839' -10 7/16" BLDG A L 03 +850' -6 5/16" BLDG A L 04 +861' -2 3/16" BLDG A L 01.2 +818' -6 23/32" RETAIL UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT E E E E T.O. CONC. SLAB TO B.O. TRUSS9'-1 1/8"TRUSS1'-6"3/4" SUBFLOORT.O. SUBFLOOR TO B.O. TRUSS9'-1 1/8"TRUSS1'-6"3/4" SUBFLOORT.O. SUBFLOOR TO B.O. TRUSS9'-1 1/8"TRUSS1'-6"3/4" SUBFLOORT.O. SUBFLOOR TO B.O. TRUSS9'-1 1/8"T.O. CONC. SLAB TO T.O. SUBFLOOR10'-7 7/8"T.O. SUBFLOOR TO T.O. SUBFLOOR10'-7 7/8"T.O. SUBFLOOR TO T.O. SUBFLOOR10'-7 7/8"T.O. CONC. SLAB TO T.O. TOPPING10'-9 1/8"T.O. TOPPING TO T.O. TOPPING10'-7 7/8"T.O. TOPPING TO T.O. TOPPING10'-7 7/8"1 1/4" TOPPING1 1/4" TOPPING1 1/4" TOPPING3 1A 1A 1A 2 CONC1'-2"20'-1 23/32"7 A351 7 A350 RETAIL UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT D D D D 3 1A 1A 1A 2 19 A351 19 A350 RETAIL CORRIDORUNIT UNIT CORRIDORUNIT UNIT CORRIDORUNIT UNIT CORRIDORUNIT UNIT CC CC CC C C 3 1A 1A 1A 2 25 A351 SINGLE PLY ROOFING MEMBRANE 3/4" F.R.T. PLYWOOD ROOF DECKING FOR A DISTANCE OF 4'-0" MIN. EACH SIDE OF SEPARATION WALL WITH NO PENETRATIONS COVER BOARD SOLID MINERAL WOOL FIRESTOPPING METAL C-STUD 1" AIR SPACE BATT INSULATION 2 LAYERS OF 1" DENSGLASS SHAFTLINER PANELS SOLID MINERAL WOOL FIRESTOPPING WOOD ROOF TRUSSES RE: STRUCTURAL ACOUSTICAL SEALANT BOTH SIDES, TAPE AND MUD OVER SEALANT JOINT WHERE EXPOSED TO VIEW SINGLE PLY ROOFING MEMBRANE ROOF DECKING COVER BOARD BATT INSULATION WOOD ROOF TRUSSES RE: STRUCTURAL ACOUSTICAL SEALANT BOTH SIDES, TAPE AND MUD OVER SEALANT JOINT WHERE EXPOSED TO VIEW GYPSUM BOARD DRAFTSTOPPING WALL AS SCHEDULED 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.FOR REVIEW ONLY - NOT FOR CONSTRUCTION6/16/2021 5:02:10 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 A350 BLDG A -RATED WALL SECTIONS The Corner Carmel, IN VWB SWM 116th Street & Rangeline Carmel, INThe Corner Carmel, IN • 01.18066.00 SCALE: 3/8" = 1'-0" 29 2 HR RATED FIRE WALL SCALE: 3/8" = 1'-0" 28 TYP. UNIT DEMISING WALL SCALE: 3/8" = 1'-0" 26 TYP. UNIT WALL - CORRIDOR WALL SCALE: 3" = 1'-0" 7 FIREWALL AT ROOF SCALE: 3" = 1'-0" 19 UNIT DEMISING WALL AT ROOF 06.16.21 Permit Set