Loading...
HomeMy WebLinkAboutA501 - FOUNDATION AND WALL DETAILSBATT INSULATION ALUMINUM FLASHING WITH HEMMED DRIP EDGE SET IN MASTIC ADHESIVE WEATHER BARRIER SLOPED BRICK ROWLOCK BRICK VENEER MORTAR NET BRICK WEEPS AT 32" O.C. THROUGH WALL FLASHING SLOPE TO DRAIN FOUNDATION; REF. STRUCTURAL FULLY GROUT BELOW GRADE CONCRETE SLAB; REF. STRUCTURAL GRANULAR BASE VAPOR BARRIER SIDING AS SCHEDULED SEE ELEVATIONS FOR ALTERNATE HEIGHT2'-0"SEISMIC VENEER ANCHORS AT 16" O.C. EACH WAY WITH FLEX FLASHING MIN. 30" BELOW GRADE11 1/4"2'-0" 2" RIGID INSULATION BATT INSULATION WEATHER BARRIER CAST STONE WATERTABLE 1/2" NON-TRACKING SEALANT MORTAR NET2'-10"2"SLOPE TO DRAIN BRICK VENEER 1 1/2" RIGID INSULATION FOUNDATION; REF. STRUCTURAL CAST STONE WEEPS AT 32" O.C. SEISMIC VENEER ANCHORS AT 16" O.C. EACH WAY WITH FLEX FLASHING 5/8" EXTERIOR SHEATHING FULLY GROUT BELOW GRADE CONCRETE SLAB; REF. STRUCTURAL GRANULAR BASE VAPOR BARRIER METAL FLASHING SEE ELEVATIONS FOR ALTERNATE HEIGHT2'-0"11 1/4"2'-4"2'-0" 2" RIGID INSULATION PROVIDE BOND-BREAKER BETWEEN BRICK & CAST STONE (TYP.) BATT INSULATION ALUMINUM FLASHING WITH HEMMED DRIP EDGE SET IN MASTIC ADHESIVE WEATHER BARRIER SLOPED BRICK ROWLOCK BRICK VENEER MORTAR NET BRICK WEEPS AT 32" O.C. THROUGH WALL FLASHING SLOPE TO DRAIN FOUNDATION; REF. STRUCTURAL FULLY GROUT BELOW GRADE CONCRETE SLAB; REF. STRUCTURAL GRANULAR BASE VAPOR BARRIER SIDING AS SCHEDULED SEE ELEVATIONS FOR ALTERNATE HEIGHT2'-2 11/256"SEISMIC VENEER ANCHORS AT 16" O.C. EACH WAY WITH FLEX FLASHING5/8" GYPSUM BOARD TO RUN TO THE CONCRETE. 2'-0"MIN. 30" BELOW GRADE11 1/4"2X WOOD FRAMING, REF. STRUCTURAL CONTINUOUS ENTIRE FACE OF SHEATHING BLDG A L 01.4 +821' -10 7/16" SLOPE TO DRAIN 2'-0" STAIR SHAFT 8" CMU STAIR WALL WEATHER BARRIER CAST STONE WATERTABLE 1/2" NON-TRACKING SEALANT MORTAR NET BRICK VENEER CAST STONE WEEPS AT 32" O.C. SEISMIC VENEER ANCHORS AT 16" O.C. EACH WAY WITH FLEX FLASHING METAL FLASHING PROVIDE BOND-BREAKER BETWEEN BRICK & CAST STONE (TYP.)2'-0"2'-9 3/4"1 1/2"BLDG A L 01.2 +818' -6 23/32" BRICK VENEER MORTAR NET BRICK WEEPS AT 32" O.C. THROUGH WALL FLASHING SLOPE TO DRAIN FOUNDATION; REF. STRUCTURAL FULLY GROUT BELOW GRADE CONCRETE SLAB; REF. STRUCTURAL GRANULAR BASE VAPOR BARRIER SEE ELEVATIONS FOR ALTERNATE HEIGHT2'-0"SEISMIC VENEER ANCHORS AT 16" O.C. EACH WAY WITH FLEX FLASHING MIN. 30" BELOW GRADE11 1/4"2'-0" 2" RIGID INSULATION CAST IN PLACE WALL, REF STRUCTURAL WEATHER BARRIER 1X BLOCKING FIBER CEMENT LAP SIDING, TO ALIGN WITH UPPER FLOORS EXTERIOR SHEATHING BLDG A L 01.1 +818' -1 13/16" BRICK VENEER MORTAR NET BRICK WEEPS AT 32" O.C. THROUGH WALL FLASHING SLOPE TO DRAIN FOUNDATION; REF. STRUCTURAL FULLY GROUT BELOW GRADE CONCRETE SLAB; REF. STRUCTURAL GRANULAR BASE VAPOR BARRIER SEE ELEVATIONS FOR ALTERNATE HEIGHT2'-0"SEISMIC VENEER ANCHORS AT 16" O.C. EACH WAY WITH FLEX FLASHING MIN. 30" BELOW GRADE11 1/4"2'-0" 2" RIGID INSULATION CAST IN PLACE WALL, REF STRUCTURAL WEATHER BARRIER 1X BLOCKING FIBER CEMENT LAP SIDING, TO ALIGN WITH UPPER FLOORS CAST IN PLACE WALL, REF STRUCTURAL WEATHER BARRIER 1X BLOCKING FIBER CEMENT LAP SIDING EXTERIOR SHEATHING 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.7/16/2021 2:22:31 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 A501 FOUNDATION AND WALL DETAILS The Corner Carmel, IN VWB SWMThe Corner Carmel, IN • 01.18066.00 1685 E. 116th Street, Carmel, IN SCALE: 1 1/2" = 1'-0" 27 BRICK FOUNDATION BASE DETAIL SCALE: 1 1/2" = 1'-0" 29 STONE FOUNDATION BASE DETAIL SCALE: 1 1/2" = 1'-0" 25 CURB AT BUILDING B GARAGE SCALE: 1 1/2" = 1'-0" 17 CMU WALL FOUNDATION SCALE: 1 1/2" = 1'-0" 13 CAST IN PLACE WALL DETAIL SCALE: 1 1/2" = 1'-0" 15 CAST IN PLACE AT SIDING A ALIGN8" CMU BLOCK2ND-5TH FLOORCAST IN PLACE CONCRETE1ST FLOOR06.16.21 Permit Set A 07.15.21 Addendum A