HomeMy WebLinkAboutA511 - BALCONY DETAILSUNIT UNIT 4"2'-8"6"3'-6"OUTSIDE FACE OF STUD TO OUTSIDE FACE OF ROUGH BEAM 5'-0" T.O. SUBFLOOR PREPRIMED STEEL RAILING SYSTEM. CONNECTIONS TO DECK AT ENDS JOIST HANGER, REF. STRUCTURAL 2X6 TREATED WOOD DECKING WITH 1/8" GAP (2) 2X10 TREATED WOOD BLOCKING WITH 1/2" PLYWOOD 1X12 FIBER CEMENT TRIM, PAINTED 2X TREATED WOOD JOISTS, REF. STRUCTURAL 2X10 WOOD BLOCKING FIBER CEMENT LAP SIDING 1" MAX 4" WEATHER BARRIER SELF-ADHERED MEMBRANE FLASHING OVER LAP SIDING BLDG A L 02 +839' -10 7/16" UNIT RETAIL SHELL PREPRIMED STEEL RAILING SYSTEM. CONNECTIONS TO DECK AT ENDS PROVIDE INTEGRAL DRIP AT CONCRETE EDGE CAST IN PLACE CONCRETE PODIUM, REF. STRUCTURAL. PROVIDE TRAFFIC COATING TO TOP AND FACE. 3"5"3"2'-8"6"PATCH HOLES WHERE TENDON POCKETS OCCUR. GRIND FACE AND RUB SMOOTH, THEN USE TEXTURED COATING TO HIDE ROUGH FACE. MAX 4"REF. STRUCTURALVARIES2 A FIBER CEMENT LAP SIDING SELF-ADHERED MEMBRANE FLASHING TO EXTEND OVER LAP SIDING WEATHER BARRIER 26 GA GALVANIZED MTL FLASHING OVER AIR BARRIER CAULKED AND SEALED AT JOINTS (TYP) SELF-ADHERING FLASHING OVER JOIST FLASHING (FOLD IN AND AROUND JAMBS AND SILL) MEMBRANE FLASHING FOR JAMB DETAIL END CANTILEVERED LVL RE: STRUCTURAL 3 "2 "3 "10"3"2" TAPE JOINT W/ BUILDING WRAP TAPE STEP 2: APPLY 3/8" x 2" BED OF SILICONE SEALANT AT PERIMETER OF JOIST STEP 4: SET TOP FLASHING IN BED OF SILICONE SEALANT AND EXTEND OVER BOTTOM FLASHING STEP 3: SET BOTTOM FLASHING IN BED OF SILICONE SEALANT AND APPLY SEALANT TO TOP OF FLASHING SHEET MTL PAN FLASHING SET IN (3) CONT. LINES OF SEALANT MINIMUM ( VERIFY COMPATIBILITY W/ WATERPROOFING), FOLD OVER SELF-ADHERED FLASHING AIR/MOISTURE BARRIER STEP 1: APPLY SELF-ADHERED FLASHING, CUT AROUND JOISTS. EXTEND 6" BEYOND METAL FLASHING ON SIDES AND BOTTOM. TAPE TOP EDGE. DO NOT TAPE SIDE AND BOTTOM EDGE TYP FLASHING SELF-ADHERING MEMBRANE FLASHING OVER JOIST FLASHING DETAIL APPLIES TO FLOOR JOISTS AND/OR FLOOR TRUSSES OUTLINE OF METAL FLASHING TO BE INSTALLED AFTER SELF- ADHERED FLASHING STEP 5: APPLY SELF-ADHERED FLEXIBLE FLASHING, EXTENDING 2" ONTO AIR/MOISTURE BARRIER AND METAL FLASHING STEP 6: APPLY SELF-ADHERED FLASHING, CUT AROUND JOIST, OVERLAP AIR/MOISTURE BARRIER FROM STEP 4 MIN 6" UNIT COWORKING SPACE 8'-8" T.O. SUBFLOOR PREPRIMED STEEL RAILING SYSTEM. CONNECTIONS TO DECK AT ENDS JOIST HANGER, REF. STRUCTURAL 2X6 TREATED WOOD DECKING WITH 1/8" GAP LVL STRUCTURAL BEAM, REF. STRUCTURAL 2X10 TREATED WOOD BLOCKING 1X12 FIBER CEMENT TRIM, PAINTED 1" 2X TREATED WOOD JOISTS, REF. STRUCTURAL 2X10 WOOD BLOCKING FIBER CEMENT LAP SIDING J CHANNEL PAC-750 ALUMINUM FULL VENT SOFFIT, DARK BRONZE FINISH 2X WOOD BLOCKING 1X4 FIBER CEMENT TRIM, PAINTED A WEATHER BARRIER SELF-ADHERED MEMBRANE FLASHING TO EXTEND OVER LAP SIDING AND BEHIND LEDGER. TYPICAL. 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.7/16/2021 2:22:44 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 A511 BALCONY DETAILS The Corner Carmel, IN VWB SWMThe Corner Carmel, IN • 01.18066.00 1685 E. 116th Street, Carmel, IN SCALE: 1 1/2" = 1'-0" 28 BALCONY DETAIL AT BUILDING A AND B SCALE: 1 1/2" = 1'-0" 25 BALCONY DETAIL AT BUILDING A SECOND FLOOR SCALE: 1" = 1'-0" 13 BALCONY FLASHING INSTALLATION SCALE: 1 1/2" = 1'-0" 16 BUILDING DETAIL AT COWORKING 06.16.21 Permit Set A 07.15.21 Addendum A