Loading...
HomeMy WebLinkAboutC601 SITE DETAILS™ Phone (888) 344-9044 Fax (423) 826-2112 2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343 STORMWATER TREATMENT SOLUTIONS www.aquashieldinc.com Aqua-Swirl Concentrator Model AS-3 HDPE Standard Detail AS-3 STD 03/20/15 Scale: Drawn By: Document: Date: JCW 1:20 U.S. Patent No. 6524473 and other Patent Pending Aqua-Swirl High Density Polyethylene (HDPE) Stormwater Treatment System * Please see accompanied Aqua-Swirl specification notes. * See Site Plan for actual system orientation. ** Orientation may vary from 90°, 180°, or custom angles to meet site conditions. 3 5/8" [91 mm] 3/8" [10 mm] 13/16" [20 mm] Manhole Frame & Cover Detail NTS For Non-Traffic Areas Only Soil 13/16" [20 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Soil Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Riser Frame Cover 38 3/8" [975 mm] Min. 9 5/8" [244 mm] Wrap Compressible Expansion Joint Material to a minimum 1-inch [25 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Backfill (90% Proctor Density) Concrete Concrete6 3/8" [163 mm] Gravel Backfill Gravel Backfill A 54" [1372 mm] Vent A 54" [1372 mm] Arched Baffle 90° **InletOutlet 10 3/4" [273 mm] OD Max 10 3/4" [273 mm] OD Max Octagonal Base Plate Plan View Pipe coupling by Contractor. 12" [305 mm] long Stub-out by Manufacturer. Pipe coupling by Contractor. 12" [305 mm] long Stub-out by Manufacturer. Ø 42" [Ø 1067 mm] Vent Riser STORMWATER TREATMENT SOLUTIONS Phone (888) 344-9044 www.aquashieldinc.com ™ Arched Baffle68" [1727 mm] 104" [2642 mm] Swirl Inlet Swirl Outlet 32" [813 mm] OD Grade (Rim) Manhole Frame and Cover by Manufacturer. (See Details) Rim elevations to match finished grade. HDPE risers can be field cut by Contractor. Varies Gravel Backfill shall extend at least 2 feet [610 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) Backfill (Sand or Crushed Stone) Bedding Undisturbed Soil 12" [305 mm] 24" [610 mm] Section A-A 3 5/8" [91 mm] Gravel Backfill 3/8" [10 mm] 13/16" [20 mm] Manhole Frame & Cover Detail NTS For H-20 Traffic Loading Areas Concrete Paving 13/16" [20 mm] Wrap Compressible Expansion Joint Material to a minimum 1-inch [25 mm] thickness around top of riser to allow transfer of traffic loading from manhole cover to concrete slab. Backfill (90% Proctor Density) Support and Level manhole frame with concrete pad. DO NOT allow manhole frame to rest upon HDPE riser. Riser Frame Cover 8" [203 mm]8" [203 mm] Gravel Backfill Concrete Paving 2 3/8" [61 mm] Typ. If traffic loading (H-20) is required or anticipated, a concrete pad must be placed over the entire Stormwater Treatment System per concrete design as calculated by Engineer. Sample details of concrete pad available upon request. PERMITTING 9025 River Road, Suite 200 | Indianapolis, Indiana 46240 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com PLOT DATE: 11/3/2021 6:40 PMPLOT SCALE: 1:2.5849EDIT DATE: 11/3/2021EDITED BY: NHORGANDRAWING FILE: P:\2021\01816\D. Drawings\Civil\Construction Documents\2021.01816.CE.C600.SD.dwgProject Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 11/3/2021 2021.01816 ARTISTIC COMPOSITE PALLETS - PARKING ADDITION 4518 W. 99th Street Carmel, Indiana REVISION SCHEDULE NO.DESCRIPTION DATEAPPROVAL PENDINGNOT FOR CONSTRUCTIONC601 SITE DETAILS