Loading...
HomeMy WebLinkAboutM100.0REFRIGERATOR OUTLET MICROWAVE OUTLET DISHWASHER POWER SUPPLY HOOD VENT POWER SUPPLY GARBAGE DISPOSAL POWER SUPPLY COOKTOP POWER SUPPLY CLOTHES DRYER OUTLET CLOTHES WASHER OUTLET 110V OUTLET 220/240V OUTLET GFCI OUTLET OUTDOOR OUTLET LOW VOLTAGE TRANSFORMER SINGLE POLE SWITCH DIMMER SWITCH 3-WAY SWITCH 4-WAY SWITCH GD WALL SWITCH GD COUNTERTOP AIR SWITCH LOW VOLTAGE LIGHTING SWITCH TIMER SWITCH OCCUPANCY SWITCH SURFACE MOUNT LIGHT FIXTURE 4" RECESSED CAN LIGHT 6" RECESSED CAN LIGHT 6" RECESSED CAN/FAN UNIT EXHAUST FAN ONLY EXHAUST FAN W/ LIGHT WALL MOUNTED SCONCE / LIGHT CEILING FAN LOW VOLTAGE LIGHT SMOKE DETECTOR CARBON MONOXIDE DETECTOR SMOKE/CARBON MONOXIDE MOTION SENSOR CEILING SPEAKER GAS SHUT-OFF KEY MAIN WATER SHUT-OFF LAUNDRY BOX FROST PROOF HOSE BIB CLEAN OUT TILE-IN DRAIN FLOOR DRAIN COLD AIR RETURN FLOOR FLOOR SUPPLY REGISTER CEILING CEILING SUPPLY REGISTER WALL WALL SUPPLY REGISTER EXTERIOR WALL EXHAUST VENT T THERMOSTAT DRYER BOX ELECTRICAL KEY PLUMBING KEY HVAC KEY DN UP FLOOR FLOOR FLOOR FLOOR WALL FLOOR cL cL cL cL cL cL cL R4 R4 R4 R4 R4R4 R4 R4 R4 R4 R4 R4 R4R4 GFCI 3 3 R4 R4 R4 R4 R4 R4 R4 R4 R4 T L WP WP 4 3 3 GFCI GFCI 3 3 CO/SD GFCI T L CT R SD CW CD H O GD DW M 33 R R R RR T 2'-5"2'-5" 1'-8"1'-11"2'-5 1/2"1'-6 1/2" 2' 10'-7 1/2" GARAGE DINING/OFFICE ENTRY FAMILY LAUNDRY 9'0" C.H. AFF EPOXY 9'0" C.H. AFF LVT BATH 9'0" C.H. AFF TILE 9'0" C.H. AFF LVT 9'0" C.H. AFF LVT OPEN TO ABOVE LVT CARPET STAIRS 9'0" C.H. AFF LVT MASTER BATH MASTER CLOSET MASTER BDRM SUNROOM KITCHEN MASTER PORCH TOILET CLOSET 9'0" C.H. AFF TILE 9'0" C.H. AFF LVT 9'0" C.H. AFF LVT 9'0" C.H. AFF LVT 9'0" C.H. AFF CONCRETE PATIO CONCRETE PATIO CONCRETE 9'0" C.H. AFF TILE 9'0" C.H. AFF LVT P3P3 E1E1 H1H1 E2E2 E3E3 P2P2 E4E4 E5E5 E6E6E7E7 E7E7 E7E7 E8E8 E9E9 E10E10 E11E11 E24E24E12E12 E13E13 E14E14 E15E15 E16E16E17E17 E18E18 E19 E19 E20E20 E21E21 E22E22 E23E23 E25E25 E26E26 E27E27 E28E28 LV1LV1 LV1LV1 P1P1 P4P4 P5P5 H2H2 H3H3 PROPOSED HVAC PLAN NOTES NOTE QTY DESCRIPTION 1 PROVIDE NEW HVAC SUPPLY AND RETURNS AS REQUIRED FROM FIRE DAMAGE. CLEAN AND REPAIR IF NECESSARY. 1 ROUGH IN AND FINISH FOR DRYER VENT. 1 INSTALL ROUGH IN FOR NEW HOOD DUCT PER HOOD SPECIFICATIONS. INSTALL EXTERIOR PENETRATION FOR DUCT. APPLIANCE INSTALLERS TO PROVIDE FINAL CONNECTION ON FINISH. H1H1 H2H2 H3H3 H1H1 H2H2 H3H3 PROPOSED ELECTRICAL PLAN NOTES NOTE QTY DESCRIPTION 1 PROVIDE AND INSTALL NEW SMOKE/CARBON MONOXIDE DETECTORS PER CODE. 1 REMOVE AND REPLACE EXISTING ELECTRICAL AS NECESSARY FROM FIRE DAMAGE. VERIFY GFCI OUTLETS ARE IN PROPER WORKING ORDER. 1 FAMILY ROOM: PROVIDE AND INSTALL (6) NEW 4" LED RECESSED CANS ON DIMMER SWITCHES. 1 ENTRY: REMOVE AND REPLACE EXISTING CHANDELIER. 1 DINING/OFFICE: REMOVE AND REPLACE EXISTING CHANDELIER. 1 PROVIDE ROUGH IN AND FINISH FOR (1) VANITY SCONCE. 3 PROVIDE ROUGH IN AND FINISH FOR GFCI OUTLET. 1 PROVIDE ROUGH IN AND FINISH FOR (2) VANITY SCONCES. 1 PROVIDE ROUGH IN AND FINISH FOR NEW CEILING FAN WITH LIGHT KIT. 1 KITCHEN- PROVIDE ROUGH IN AND FINISH FOR (8) NEW 4" LED RECESSED CANS ON DIMMER SWITCHES. 1 PROVIDE ROUGH IN AND FINISH FOR (3) NEW PENDANT LIGHTS ON DIMMER SWITCHES. 1 PROVIDE ROUGH IN AND FINISH FOR NEW CEILING FAN. 1 PROVIDE ROUGH IN AND FINISH FOR NEW OUTDOOR CEILING FAN WITH LIGHT KIT. 1 PROVIDE ROUGH IN AND FINISH FOR (2) NEW OUTDOOR RECESSED CAN LIGHTS. 1 PROVIDE ROUGH IN AND FINISH FOR (2) ISLAND OUTLETS 1 PROVIDE PROVIDE POWER FOR DOUBLE OVEN/ MICROWAVE. 1 PROVIDE PROVIDE POWER FOR COOKTOP AND RANGE HOOD 1 PROVIDE PROVIDE POWER FOR GARBAGE DISPOSAL WITH AIR SWITCH 1 PROVIDE PROVIDE POWER FOR DISHWASHER. 1 PROVIDE ROUGH IN AND FINISH FOR (2) WALL ART LIGHTS. 1 PROVIDE PROVIDE POWER FOR REFRIGERATOR. 1 PROVIDE POWER FOR WASHER AND DRYER. 1 PROVIDE ROUGH IN AND FINISH FOR NEW SURFACE MOUNTED LIGHT FIXTURE. 1 SUN ROOM: PROVIDE AND INSTALL (6) NEW 4" LED RECESSED CANS ON DIMMER SWITCHES. 1 MASTER BATH: PROVIDE AND INSTALL (2) NEW 4" LED RECESSED CANS ON DIMMER SWITCHES. 1 MASTER BATH: PROVIDE AND INSTALL (1) NEW 6" LED RECESSED CAN/FAN. 1 MASTER BATH: PROVIDE OUTLET FOR FUTURE BIDET. 1 MASTER CLOSET: PROVIDE ROUGH IN AND FINISH FOR NEW CHANDELIER E1E1 E2E2 E3E3 E4E4 E5E5 E6E6 E7E7 E8E8 E9E9 E10E10 E11E11 E12E12 E13E13 E14E14 E15E15 E16E16 E17E17 E18E18 E19E19 E20E20 E21E21 E22E22 E23E23 E24E24 E25E25 E26E26 E27E27 E28E28 E1E1 E2E2 E3E3 E4E4 E5E5 E6E6 E7E7 E8E8 E9E9 E10E10 E11E11 E12E12 E13E13 E14E14 E15E15 E16E16 E17E17 E18E18 E19E19 E20E20 E21E21 E22E22 E23E23 E24E24 E25E25 E26E26 E27E27 E28E28 PROPOSED PLUMBING PLAN NOTES NOTE QTY DESCRIPTION 1 ROUGH IN AND FINISH FOR (2) VANITY SINKS, (1) TOILET, (1) SHOWER HEAD, (1) VALVE. 1 ROUGH IN AND FINISH FOR NEW TOILET AND SINK 1 ROUGH IN AND FINISH FOR NEW KITCHEN SINK AND FAUCET. 1 ROUGH IN AND FINISH FOR (1) LAUNDRY SINK AND FAUCET. 1 ROUGH IN AND FINISH FOR WASHER BOX P1P1 P2P2 P3P3 P4P4 P5P5 P1P1 P2P2 P3P3 P4P4 P5P5 PROPOSED LOW VOLTAGE PLAN NOTES NOTE QTY DESCRIPTION 2 PROVIDE POWER AND WIRING FOR LOW VOLTAGE TRANSFORMER FOR UNDER CABINET LIGHTING. INSTALL FINISH FOR LIGHTING. CUSTOM LIVING TO PROVIDE DRIVER AND FIXTURES LV1LV1LV1LV1 4" 3000K MODEL NO. JUNO-4RLD G3 09LM 30K 90CRI 1 20 FRPC WWH M6 DUPLEX WHITE LUTRON TOGGLE DIMMER SWITCH WHITE SELVIO RESIDENCEFIRE RESTORATION3208 Maralice Dr.Carmel IN 46033Date:Revision : A12 SHEET OF 18 SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 4622010/27/2021 DATE : [PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: JONNI BERKLEYE: jonni@customlivingusa.comC: 317-801-3073PROPOSED 1ST FLOOR M.E.P. PLAN SCALE: 1/4" = 1' NEW OUTLET DEVICE STYLE NEW SWITCH DEVICE STYLE RECESSED CAN LIGHTS N GENERAL M.E.P NOTES HVAC Contractor is responsible for engineering calculation necessary for correct sizing of new equipment and ductwork being supplied, fabricated and installed for the project. HVAC ductwork installed in unconditioned areas to be insulated and sealed per Building Code Standards. HVAC contractor to start, test, and balance any new equipment and ductwork to assure proper operation of new systems. Final plumbing materials selected may have an affect on the final Plumbing Material and Installation Budgets. Owners understand that if additional plumbing, electrical or ductwork is found in walls being deleted that is not included on the plans there will be a Change Order during construction to relocate as necessary. Owners understand that during mechanical rough-ins there will be times when the water service will be shut off to areas in the home. Plumbing and Lighting fixtures supplied by Owner will not be warranted by Custom Living Plumbing and Lighting fixtures supplied by Owner must be selected and on-site prior to start of mechanical rough-ins. 11/08/21