HomeMy WebLinkAboutM100.0REFRIGERATOR OUTLET
MICROWAVE OUTLET
DISHWASHER POWER SUPPLY
HOOD VENT POWER SUPPLY
GARBAGE DISPOSAL POWER SUPPLY
COOKTOP POWER SUPPLY
CLOTHES DRYER OUTLET
CLOTHES WASHER OUTLET
110V OUTLET
220/240V OUTLET
GFCI OUTLET
OUTDOOR OUTLET
LOW VOLTAGE TRANSFORMER
SINGLE POLE SWITCH
DIMMER SWITCH
3-WAY SWITCH
4-WAY SWITCH
GD WALL SWITCH
GD COUNTERTOP AIR SWITCH
LOW VOLTAGE LIGHTING SWITCH
TIMER SWITCH
OCCUPANCY SWITCH
SURFACE MOUNT LIGHT FIXTURE
4" RECESSED CAN LIGHT
6" RECESSED CAN LIGHT
6" RECESSED CAN/FAN UNIT
EXHAUST FAN ONLY
EXHAUST FAN W/ LIGHT
WALL MOUNTED SCONCE / LIGHT
CEILING FAN
LOW VOLTAGE LIGHT
SMOKE DETECTOR
CARBON MONOXIDE DETECTOR
SMOKE/CARBON MONOXIDE
MOTION SENSOR
CEILING SPEAKER
GAS SHUT-OFF KEY
MAIN WATER SHUT-OFF
LAUNDRY BOX
FROST PROOF HOSE BIB
CLEAN OUT
TILE-IN DRAIN
FLOOR DRAIN
COLD AIR RETURN
FLOOR FLOOR SUPPLY REGISTER
CEILING CEILING SUPPLY REGISTER
WALL WALL SUPPLY REGISTER
EXTERIOR WALL EXHAUST VENT
T THERMOSTAT
DRYER BOX
ELECTRICAL KEY
PLUMBING KEY
HVAC KEY
DN
UP
FLOOR FLOOR
FLOOR
FLOOR
WALL
FLOOR
cL
cL
cL
cL
cL
cL cL
R4 R4
R4 R4
R4R4
R4
R4 R4
R4 R4 R4 R4R4
GFCI
3
3
R4
R4
R4
R4
R4 R4
R4
R4
R4
T L
WP
WP
4 3 3
GFCI
GFCI
3
3
CO/SD
GFCI
T L
CT R
SD
CW
CD
H O
GD
DW M
33
R R R
RR
T
2'-5"2'-5" 1'-8"1'-11"2'-5 1/2"1'-6 1/2" 2'
10'-7 1/2"
GARAGE
DINING/OFFICE
ENTRY
FAMILY
LAUNDRY
9'0" C.H.
AFF
EPOXY
9'0" C.H. AFF
LVT
BATH
9'0" C.H. AFF
TILE
9'0" C.H. AFF
LVT 9'0" C.H. AFF
LVT
OPEN TO ABOVE
LVT
CARPET STAIRS
9'0" C.H. AFF
LVT
MASTER BATH
MASTER CLOSET
MASTER BDRM
SUNROOM
KITCHEN
MASTER PORCH
TOILET CLOSET
9'0" C.H. AFF
TILE
9'0" C.H. AFF
LVT
9'0" C.H. AFF
LVT
9'0" C.H. AFF
LVT
9'0" C.H. AFF
CONCRETE
PATIO
CONCRETE
PATIO
CONCRETE
9'0" C.H. AFF
TILE
9'0" C.H. AFF
LVT
P3P3 E1E1
H1H1
E2E2
E3E3
P2P2
E4E4
E5E5
E6E6E7E7
E7E7
E7E7
E8E8
E9E9
E10E10
E11E11
E24E24E12E12
E13E13
E14E14
E15E15
E16E16E17E17
E18E18
E19 E19
E20E20
E21E21
E22E22
E23E23
E25E25
E26E26
E27E27
E28E28
LV1LV1
LV1LV1
P1P1
P4P4
P5P5
H2H2
H3H3
PROPOSED HVAC PLAN NOTES
NOTE QTY DESCRIPTION
1 PROVIDE NEW HVAC SUPPLY AND RETURNS AS REQUIRED
FROM FIRE DAMAGE. CLEAN AND REPAIR IF NECESSARY.
1 ROUGH IN AND FINISH FOR DRYER VENT.
1
INSTALL ROUGH IN FOR NEW HOOD DUCT PER HOOD
SPECIFICATIONS. INSTALL EXTERIOR PENETRATION FOR
DUCT. APPLIANCE INSTALLERS TO PROVIDE FINAL
CONNECTION ON FINISH.
H1H1
H2H2
H3H3
H1H1
H2H2
H3H3
PROPOSED ELECTRICAL PLAN NOTES
NOTE QTY DESCRIPTION
1 PROVIDE AND INSTALL NEW SMOKE/CARBON MONOXIDE
DETECTORS PER CODE.
1
REMOVE AND REPLACE EXISTING ELECTRICAL AS
NECESSARY FROM FIRE DAMAGE. VERIFY GFCI OUTLETS
ARE IN PROPER WORKING ORDER.
1 FAMILY ROOM: PROVIDE AND INSTALL (6) NEW 4" LED
RECESSED CANS ON DIMMER SWITCHES.
1 ENTRY: REMOVE AND REPLACE EXISTING CHANDELIER.
1 DINING/OFFICE: REMOVE AND REPLACE EXISTING
CHANDELIER.
1 PROVIDE ROUGH IN AND FINISH FOR (1) VANITY SCONCE.
3 PROVIDE ROUGH IN AND FINISH FOR GFCI OUTLET.
1 PROVIDE ROUGH IN AND FINISH FOR (2) VANITY SCONCES.
1 PROVIDE ROUGH IN AND FINISH FOR NEW CEILING FAN
WITH LIGHT KIT.
1 KITCHEN- PROVIDE ROUGH IN AND FINISH FOR (8) NEW 4"
LED RECESSED CANS ON DIMMER SWITCHES.
1 PROVIDE ROUGH IN AND FINISH FOR (3) NEW PENDANT
LIGHTS ON DIMMER SWITCHES.
1 PROVIDE ROUGH IN AND FINISH FOR NEW CEILING FAN.
1 PROVIDE ROUGH IN AND FINISH FOR NEW OUTDOOR
CEILING FAN WITH LIGHT KIT.
1 PROVIDE ROUGH IN AND FINISH FOR (2) NEW OUTDOOR
RECESSED CAN LIGHTS.
1 PROVIDE ROUGH IN AND FINISH FOR (2) ISLAND OUTLETS
1 PROVIDE PROVIDE POWER FOR DOUBLE OVEN/
MICROWAVE.
1 PROVIDE PROVIDE POWER FOR COOKTOP AND RANGE
HOOD
1 PROVIDE PROVIDE POWER FOR GARBAGE DISPOSAL WITH
AIR SWITCH
1 PROVIDE PROVIDE POWER FOR DISHWASHER.
1 PROVIDE ROUGH IN AND FINISH FOR (2) WALL ART LIGHTS.
1 PROVIDE PROVIDE POWER FOR REFRIGERATOR.
1 PROVIDE POWER FOR WASHER AND DRYER.
1 PROVIDE ROUGH IN AND FINISH FOR NEW SURFACE
MOUNTED LIGHT FIXTURE.
1 SUN ROOM: PROVIDE AND INSTALL (6) NEW 4" LED
RECESSED CANS ON DIMMER SWITCHES.
1 MASTER BATH: PROVIDE AND INSTALL (2) NEW 4" LED
RECESSED CANS ON DIMMER SWITCHES.
1 MASTER BATH: PROVIDE AND INSTALL (1) NEW 6" LED
RECESSED CAN/FAN.
1 MASTER BATH: PROVIDE OUTLET FOR FUTURE BIDET.
1 MASTER CLOSET: PROVIDE ROUGH IN AND FINISH FOR
NEW CHANDELIER
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
E7E7
E8E8
E9E9
E10E10
E11E11
E12E12
E13E13
E14E14
E15E15
E16E16
E17E17
E18E18
E19E19
E20E20
E21E21
E22E22
E23E23
E24E24
E25E25
E26E26
E27E27
E28E28
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
E7E7
E8E8
E9E9
E10E10
E11E11
E12E12
E13E13
E14E14
E15E15
E16E16
E17E17
E18E18
E19E19
E20E20
E21E21
E22E22
E23E23
E24E24
E25E25
E26E26
E27E27
E28E28
PROPOSED PLUMBING PLAN NOTES
NOTE QTY DESCRIPTION
1 ROUGH IN AND FINISH FOR (2) VANITY SINKS, (1) TOILET, (1)
SHOWER HEAD, (1) VALVE.
1 ROUGH IN AND FINISH FOR NEW TOILET AND SINK
1 ROUGH IN AND FINISH FOR NEW KITCHEN SINK AND
FAUCET.
1 ROUGH IN AND FINISH FOR (1) LAUNDRY SINK AND FAUCET.
1 ROUGH IN AND FINISH FOR WASHER BOX
P1P1
P2P2
P3P3
P4P4
P5P5
P1P1
P2P2
P3P3
P4P4
P5P5
PROPOSED LOW VOLTAGE PLAN NOTES
NOTE QTY DESCRIPTION
2
PROVIDE POWER AND WIRING FOR LOW VOLTAGE
TRANSFORMER FOR UNDER CABINET LIGHTING. INSTALL
FINISH FOR LIGHTING. CUSTOM LIVING TO PROVIDE DRIVER
AND FIXTURES
LV1LV1LV1LV1
4" 3000K
MODEL NO.
JUNO-4RLD
G3 09LM 30K
90CRI 1 20
FRPC WWH
M6
DUPLEX
WHITE
LUTRON
TOGGLE
DIMMER
SWITCH WHITE
SELVIO RESIDENCEFIRE RESTORATION3208 Maralice Dr.Carmel IN 46033Date:Revision
:
A12
SHEET OF 18
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 4622010/27/2021
DATE
:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: JONNI BERKLEYE: jonni@customlivingusa.comC: 317-801-3073PROPOSED 1ST FLOOR M.E.P. PLAN
SCALE: 1/4" = 1'
NEW OUTLET DEVICE STYLE
NEW SWITCH DEVICE STYLE
RECESSED CAN LIGHTS
N
GENERAL M.E.P NOTES
HVAC Contractor is responsible for engineering
calculation necessary for correct sizing of new
equipment and ductwork being supplied, fabricated and
installed for the project.
HVAC ductwork installed in unconditioned areas to be
insulated and sealed per Building Code Standards.
HVAC contractor to start, test, and balance any new
equipment and ductwork to assure proper operation of
new systems.
Final plumbing materials selected may have an affect
on the final Plumbing Material and Installation Budgets.
Owners understand that if additional plumbing,
electrical or ductwork is found in walls being deleted
that is not included on the plans there will be a Change
Order during construction to relocate as necessary.
Owners understand that during mechanical rough-ins
there will be times when the water service will be shut
off to areas in the home.
Plumbing and Lighting fixtures supplied by Owner will
not be warranted by Custom Living
Plumbing and Lighting fixtures supplied by Owner must
be selected and on-site prior to start of mechanical
rough-ins.
11/08/21