HomeMy WebLinkAboutM101.0REFRIGERATOR OUTLET
MICROWAVE OUTLET
DISHWASHER POWER SUPPLY
HOOD VENT POWER SUPPLY
GARBAGE DISPOSAL POWER SUPPLY
COOKTOP POWER SUPPLY
CLOTHES DRYER OUTLET
CLOTHES WASHER OUTLET
110V OUTLET
220/240V OUTLET
GFCI OUTLET
OUTDOOR OUTLET
LOW VOLTAGE TRANSFORMER
SINGLE POLE SWITCH
DIMMER SWITCH
3-WAY SWITCH
4-WAY SWITCH
GD WALL SWITCH
GD COUNTERTOP AIR SWITCH
LOW VOLTAGE LIGHTING SWITCH
TIMER SWITCH
OCCUPANCY SWITCH
SURFACE MOUNT LIGHT FIXTURE
4" RECESSED CAN LIGHT
6" RECESSED CAN LIGHT
6" RECESSED CAN/FAN UNIT
EXHAUST FAN ONLY
EXHAUST FAN W/ LIGHT
WALL MOUNTED SCONCE / LIGHT
CEILING FAN
LOW VOLTAGE LIGHT
SMOKE DETECTOR
CARBON MONOXIDE DETECTOR
SMOKE/CARBON MONOXIDE
MOTION SENSOR
CEILING SPEAKER
GAS SHUT-OFF KEY
MAIN WATER SHUT-OFF
LAUNDRY BOX
FROST PROOF HOSE BIB
CLEAN OUT
TILE-IN DRAIN
FLOOR DRAIN
COLD AIR RETURN
FLOOR FLOOR SUPPLY REGISTER
CEILING CEILING SUPPLY REGISTER
WALL WALL SUPPLY REGISTER
EXTERIOR WALL EXHAUST VENT
T THERMOSTAT
DRYER BOX
ELECTRICAL KEY
PLUMBING KEY
HVAC KEY
NDN
FLOOR FLOOR
CEILING
CEILING
CEILING
FLOORSD
SD
SD
GFCI
R
R
CO/SD
SD
SD SD
R
GFCI
R
GFCI
R
OPEN BELOW
J/J BATH
8'0" CH AFF
CARPET
8'0" CH
AFF
CARPET
8'0" CH
AFF
CARPET
CLOSET
BEDROOM 1
8'0" CH
AFF
CARPET
BATH
CLOSET
CLOSET
BATH
MASTER BATH
8'0" CH AFF
TILE
Shelving
CLOSET
HALL
8'0" CH AFF
CARPET
ATTIC STORAGE
P2P2
E4E4
E1E1
E2E2
P1P1
E3E3
E3E3
E3E3
H1H1
E5E5
E6E6
8'0" CH
AFF
CARPET
BEDROOM 2BEDROOM 3
ATTIC
CHASEOPEN STORAGE OPEN STORAGE
4" 3000K
MODEL NO.
JUNO-4RLD
G3 09LM 30K
90CRI 1 20
FRPC WWH
M6
DUPLEX
WHITE
LUTRON
TOGGLE
DIMMER
SWITCH WHITE
PROPOSED HVAC PLAN NOTES
NOTE QTY DESCRIPTION
1 PROVIDE NEW HVAC SUPPLY AND RETURNS AS REQUIRED
FROM FIRE DAMAGE. CLEAN AND REPAIR IF NECESSARY.H1H1H1H1
PROPOSED ELECTRICAL PLAN NOTES
NOTE QTY DESCRIPTION
1
REMOVE AND REPLACE EXISTING ELECTRICAL AS
NECESSARY FROM FIRE DAMAGE. VERIFY GFCI OUTLETS
ARE IN PROPER WORKING ORDER.
1 NEW LED RECESSED CANS ON DIMMER SWITCHES IN
EXISTING LOCATIONS
3 PROVIDE ROUGH IN AND FINISH FOR CEILING FAN WITH
LIGHT KIT.
1 PROVIDE AND INSTALL NEW SMOKE/CARBON MONOXIDE
DETECTORS PER CODE.
1 PROVIDE ROUGH IN AND FINISH FOR (1) VANITY LIGHT AND
(2) GFCI OUTLETS PER CODE.
1 PROVIDE ROUGH IN AND FINISH FOR (2) VANITY LIGHTS
AND (2) GFCI OUTLETS PER CODE.
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
PROPOSED PLUMBING PLAN NOTES
NOTE QTY DESCRIPTION
1 PULL AND REPLACE (2) VANITY SINKS/FAUCETS, (1) TOILET,
(1) SHOWER HEAD AND VALVE.
1 ROUGH IN AND FINISH FOR (2) NEW VANITY SINKS/
FAUCETS, (1) TOILET, AND (1) TUB/SHOWER COMBO.
P1P1
P2P2
P1P1
P2P2 SELVIO RESIDENCEFIRE RESTORATION3208 Maralice Dr.Carmel IN 46033Date:Revision
:
A13
SHEET OF 18
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 4622010/27/2021
DATE
:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: JONNI BERKLEYE: jonni@customlivingusa.comC: 317-801-3073PROPOSED 2ND FLOOR M.E.P. PLAN
SCALE: 1/4 = 1'
RECESSED CAN LIGHTS
NEW OUTLET DEVICE STYLE
NEW SWITCH DEVICE STYLE
GENERAL M.E.P NOTES
HVAC Contractor is responsible for engineering
calculation necessary for correct sizing of new
equipment and ductwork being supplied, fabricated and
installed for the project.
HVAC ductwork installed in unconditioned areas to be
insulated and sealed per Building Code Standards.
HVAC contractor to start, test, and balance any new
equipment and ductwork to assure proper operation of
new systems.
Final plumbing materials selected may have an affect
on the final Plumbing Material and Installation Budgets.
Owners understand that if additional plumbing,
electrical or ductwork is found in walls being deleted
that is not included on the plans there will be a Change
Order during construction to relocate as necessary.
Owners understand that during mechanical rough-ins
there will be times when the water service will be shut
off to areas in the home.
Plumbing and Lighting fixtures supplied by Owner will
not be warranted by Custom Living
Plumbing and Lighting fixtures supplied by Owner must
be selected and on-site prior to start of mechanical
rough-ins.