Loading...
HomeMy WebLinkAboutS100.13DB3318 B3018 B27 B27 3DB18 3DB3318 SB36 24DW B30183DB3018 SB4818 RB36 12 TRAY DIVIDERSB21 SB243DB153DB21SB24B661824TRASH 12 SPICE PULL OUT 1DB27 3DB3018 B1351 B253B253B2533DB153DB3318 B3018 B27 B27 3DB18 3DB3318 SB36 24DW B3018 3DB3018 SB4818 RB36 12 TRAY DIVIDERSB21 SB24 3DB153DB21 SB24 B6618 24TRASH 12 SPICE PULL OUT 1DB27 3DB3018 B1351 B253B253B2533DB15 OTC3024102U3024102 U3024102W2742W2742 W3333TH W3333TH W2736 W2736 D11 D10 W04 W06D09 W06 D08 D05 D03 D04 D06 D12 D05 W05 D07 W01 4068 D02 D01 28402840 W02 DN UP FLOOR FLOOR FLOOR FLOOR WALL FLOORFLOOR JOIST DIRECTIONcL cL cL cL cL cL cL R4 R4 R4R4 R4R4 R4 R4 R4 R4 R4 R4 R4R4 GFCI 3 3 R4 R4 R4 R4 R4 R4 R4 R4 R4 T L WP WP 4 3 3 GFCI GFCI 3 3 CO/SD GFCI T L CT R SD CW CD H O DWM 33 R R R RR T 4'-9 1/2"10'-3"11'-7"5'17'-1 1/2"12'-3" 4'-9"5'10'-6"5'-11"10'-9" 9'-6" 11'-6 1/2" 19'-7" brick to brick 8'-7"4'3'-7 1/2" 4'-9 1/2" 4'-9 1/2"12'19'-6" 15'-5"2'5'-10"9'-6 1/2"2'-5 1/2"6'-1 1/2"13'-7 1/2"7'-6" GARAGE DINING/OFFICE ENTRY FAMILY LAUNDRY 9'0" C.H. AFF EPOXY 9'0" C.H. AFF LVT BATH 9'0" C.H. AFF TILE 9'0" C.H. AFF LVT 9'0" C.H. AFF LVT OPEN TO ABOVE LVT CARPET STAIRS 9'0" C.H. AFF LVT MASTER BATH MASTER CLOSET MASTER BDRM SUNROOM KITCHEN MASTER PORCH F3F3 D2D2 F7F7 D3D3 D4D4 D1D1 D5D5 TOILET CLOSET 9'0" C.H. AFF TILE 9'0" C.H. AFF LVT 9'0" C.H. AFF LVT 9'0" C.H. AFF LVT 9'0" C.H. AFF CONCRETE PATIO CONCRETE PATIO CONCRETE 9'0" C.H. AFF TILE 9'0" C.H. AFF LVT F2F2 F6F6 F5F5 F8F8 F9F9 F1F1 F10F10 F4F4 W2712 W2712 FRAMING PLAN NOTES NOTE QTY DESCRIPTION 1 RE-FRAME AS REQUIRED FROM FIRE DAMAGE 1 FRAME NEW EXTERIOR WALLS AS SHOWN ON PLAN. INSTALL TYVEK SHEATHING. 1 FRAME NEW NON-LOAD BEARING INTERIOR WALLS AS SHOWN ON PLAN. 1 FRAMER TO INSTALL NEW WINDOWS AND DOORS PER PLAN. 1 FRAME NEW FLOOR SYSTEM AND SUBFLOOR TO MATCH EXISTING. 1 MATCH EXISTING FLOOR SYSTEM (NEW 2X10@16" ON CENTER) 1 FRAME AND BLOCK FOR SHOWER NICHE. SEE TILE DETAIL DRAWINGS FOR NICHE DIMENSIONS. 1 FRAME HALF WALL FOR NEW SUNROOM ADDITION. 1 FRAME FOR NEW CASED OPENING INTO ADDITION. 1 FRAME DROPPED BEAM FOR NEW ADDITION. EXACT SPECIFICATIONS TO BE DETERMINED BY STRUCTURAL ENGINEER. F1F1 F2F2 F3F3 F4F4 F5F5 F6F6 F7F7 F8F8 F9F9 F10F10 F1F1 F2F2 F3F3 F4F4 F5F5 F6F6 F7F7 F8F8 F9F9 F10F10 INSULATION PLAN NOTES NOTE QTY DESCRIPTION 1 FOAM AND FIRE CAULK ALL NEW WALLS TO MEET MUNICIPAL FIRE CODE REQUIREMENTS. FINAL INSULATION SCOPE TO BE DETERMINED ON A FIELD WALK FOLLOWING MECHANICAL ROUGH-INS. 1 PROVIDE AND INSTALL EXTERIOR WALL INSULATION PER CODE. I1I1 I2I2 I1I1 I2I2 DRYWALL PLAN NOTES NOTE QTY DESCRIPTION 1 ALL NEW DRYWALL ON WALLS AND CEILING AS REQUIRED FOR NEW ADDITION. 1 INSTALL DRYWALL ON NEW FRAMED WALLS. MATCH EXISTING FINISH LEVEL. 1 PATCH AND REPAIR CEILING DRYWALL AS NEEDED BY DEMO 1 PATCH AND REPAIR DRYWALL AS NEEDED FROM CABINET REMOVAL. 1 REFRAME AND PATCH WALL AS NEEDED FROM DEMO D1D1 D2D2 D3D3 D4D4 D5D5 D1D1 D2D2 D3D3 D4D4 D5D5 DOOR SCHEDULE NUMBER FLOOR QTY R/O TOP WIDTH HEIGHT DESCRIPTION SUPPLIER D01 2 1 62"X82 1/2" 80" 60 " 80 " DOUBLE HINGED-GLASS PANEL D02 2 1 25"X82 1/2" 80" 23 " 80 " HINGED-PANEL D03 2 1 32"X82 1/2" 80" 30 " 80 " HINGED-PANEL D04 2 1 29 1/2"X82 1/2" 80" 27 1/2 " 80 " HINGED-PANEL D05 2 2 38"X82 1/2" 80" 36 " 80 " DOUBLE HINGED-PANEL D06 2 1 38"X83" 80" 36 " 80 " EXT. HINGED-GLASS PANEL D07 2 1 38"X82 1/2" 80" 36 " 80 " HINGED-PANEL D08 2 1 74"X83" 80" 72 " 80 " EXT. SLIDER-GLASS PANEL FRANKLIN D09 2 1 32"X83" 80" 30 " 80 " EXT. HINGED-GLASS PANEL FRANKLIN D10 2 1 194"X87" 84" 192 " 84 " GARAGE-GARAGE DOOR CHD06 OVERHEAD DOOR COMPANY OF INDIANAPOLIS D11 2 1 110"X87" 84" 108 " 84 " GARAGE-GARAGE DOOR CHD06 OVERHEAD DOOR COMPANY OF INDIANAPOLIS D12 2 1 38"X83" 80" 36 " 80 " EXT. HINGED-GLASS PANEL FRANKLIN WINDOW SCHEDULE NUMBER FLOOR QTY R/O BOTTOM TOP WIDTH HEIGHT TEMPERED DESCRIPTION SUPPLIER W01 2 1 121"X49" 32" 80" 120 " 48 " TRIPLE CASEMENT-LHL/RHR FRANKLIN W02 2 1 33"X49" 32" 80" 32 " 48 " SINGLE CASEMENT-HR FRANKLIN W04 2 1 63"X49" 32" 80" 62 " 48 " MULLED UNIT FRANKLIN W05 2 1 97"X49" 32" 80" 96 " 48 " TRIPLE CASEMENT-LHL/RHR FRANKLIN W06 2 2 13"X76" 5" 80" 12 " 75 " FIXED GLASS FRANKLIN EXISTING 2X4 FRAMING DEMOLITION & FRAMING KEY NO DEMO IN THIS ROOM EXISTING 2X6 FRAMING WALL SECTION TO BE REMOVED NEW 2x4 FRAMING NEW 2X6 FRAMING BULK HEAD / LOWERED CEILING 1'-4" 9'HEADER- DOUBLE 2X10 (U.N.O) DOUBLE TOP PLATE KING STUD CRIPPLE STUD SINGLE BOTTOM PLATE 16" FLOOR JOISTS @ 16" O.C. O.C. 2x12 FLOOR JOIST SELVIO RESIDENCEFIRE RESTORATION3208 Maralice Dr.Carmel IN 46033Date:Revision : A7 SHEET OF 18 SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 4622010/27/2021 DATE : [PRINTS TO SCALE IF PRINTED ON 24" X 36" ] PROPOSED 1ST FLOOR PLAN SCALE: 1/4" = 1'DESIGNER: JONNI BERKLEYE: jonni@customlivingusa.comC: 317-801-3073TYPICAL WALL SECTION SCALE: 3/8" = 1' GENERAL PROPOSED PLAN NOTES Framing contractors are responsible for all labor, for the scope of work specified on the drawings provided by Custom Living. Owner understands that Custom Living has only provided a labor and material allowance for the scope of Rough Carpentry work specified on the drawings. Any additional work added or uncovered during this scope will be filed as a Change Orde r during construction Owner understands that the drywall allowance is based on an estimated board count and square footage take-off. A final walk through with a drywall contractor after framing and mechanical rough-ins will be necessary to finalize drywall installation and finish budgets. Final drywall touch-ups will follow countertop installation. N 11/08/21