HomeMy WebLinkAboutS101.0DN
SB3721 SB3721
SB34214DB1221SB3421SB3721 SB3721
SB3421 4DB1221 SB3421FLOOR FLOOR
FLOOR
FLOOR
FLOOR FLOOR
CEILING
CEILING
CEILING
CEILING
CEILING
30X22
ATTIC
ACCESS
FLOORRRRR
R
R
R
SD
SDSD
SD SD
GFCI
R4
5'-2 3/8" 17'-9 7/8" 12'-7" 7'-9 3/4" 13'-1 1/2"
56'-6 1/2"
12'-8"15'-7 3/4" 10'-11 3/4" 4'-3 1/2" 12'-11 1/2"
56'-6 1/2"6'-11" 14'-8 1/2" 9'-11" 5'-3"42'-1" 13'-4 1/2"17'-7 1/2" 4'-9" 35'-9"6'-4"9'-1"1/8"3'-2 3/8"2'-5 1/8"
CL
4'-8 7/8"10 5/8"
5'-7 1/2"
CL
1'-5 1/2"CL 3'-10"1'-5"6'-8 1/2"3'-3 3/8"2'-2 1/2"1'-2 5/8" 6'-8 1/2" 111 SQ FT
27 SQ FT
298 SQ FT
192 SQ FT
175 SQ FT
333 SQ FT
180 SQ FT
147 SQ FT
8 SQ FT
18 SQ FT
4 SQ FT
44 SQ FT
19 SQ FT
20 SQ FT
114 SQ FT
53 SQ FT
MASTER CLOSET
MASTER BATH
MASTER BDRM
HALL
OPEN BELOW
BEDROOM 2
CLOSET
CLOSET
BEDROOM 3
ATTIC
BEDROOM 4
LINENBATH
CLOSET
STORAGE
VAULTED CLG
CARPET
8'0" CH AFF
CARPET
8'0" CH AFF
CARPET
8'0" CH AFF
CARPET
8'0" CH AFF
CARPET
8'0" CH AFF
CARPET
8'0" CH AFF
CARPET
8'0" CH AFF
CARPET
CHASE
8'0" CH AFF
VINYL
8'0" CH AFF
CARPET
8'0" CH AFF
TILE
8'0" CH AFF
CARPET
Shelving
E2E2
P2P2D2D2
D1D1
D2D2
D4D4
D3D3
P3P3
D4D4
D4D4
D4D4
H2H2
D1D1
D1D1
D1D1
D1D1
D1D1
D1D1
D5D5
EXISTING 2X4 FRAMING
DEMOLITION & FRAMING KEY
NO DEMO IN THIS ROOM
EXISTING 2X6 FRAMING
WALL SECTION TO BE REMOVED
NEW 2x4 FRAMING
NEW 2X6 FRAMING
BULK HEAD / LOWERED CEILING
DEMO & PREP PLAN NOTES
NOTE QTY DESCRIPTION
7 REMOVE ALL FLOORING DOWN TO SUBFLOOR AND PREP
FOR NEW CARPET.
2 REMOVE EXISTING CABINETS, PLUMBING FIXTURES,
COUNTERTOPS, AND MIRRORS.
1 REMOVE ALL DRYWALL NECESSARY FOR ELECTRICAL
REWIRE
4 DEMO DOWN TO STUDS.
1 ATTIC - REMOVE ALL INSULATION & TRUSSWORK AS
NECESSARY
D1D1
D2D2
D3D3
D4D4
D5D5
D1D1
D2D2
D3D3
D4D4
D5D5
PLUMBING DEMO/DISCONNECT PLAN NOTES
NOTE QTY DESCRIPTION
1 SEPARATE PLUMBING PERMIT NOT REQUIRED.
1 DISCONNECT PLUMBING LINES TO SINK, TOILET SHOWER
AND TUB PRIOR TO DEMOLITION. STUB LINES IN FLOOR.
1
DISCONNECT PLUMBING LINES TO SINK, TOILET SHOWER
AND TUB PRIOR TO DEMOLITION. REMOVE LINES
COMPLETELY FROM FIRE DAMAGE.
P1P1
P2P2
P3P3
P1P1
P2P2
P3P3
ELECTRICAL DEMO/DISCONNECT NOTES
NOTE QTY DESCRIPTION
1 SEPARATE ELECTRICAL PERMIT NOT REQUIRED.
1 EXISTING ELECTRICAL IN WALLS TO BE DELETED PRIOR TO
WALL DEMOLITION.
E1E1
E2E2
E1E1
E2E2
HVAC DEMO/DISCONNECT NOTES
NOTE QTY DESCRIPTION
1 SEPARATE HVAC PERMIT NOT REQUIRED.
1 EXISTING HVAC VENT LOCATIONS TO BE RELOCATED.
H1H1
H2H2
H1H1
H2H2
SELVIO RESIDENCEFIRE RESTORATION3208 Maralice Dr.Carmel IN 46033Date:Revision
:
A5
SHEET OF 18
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 4622010/27/2021
DATE
:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: JONNI BERKLEYE: jonni@customlivingusa.comC: 317-801-3073SECOND FLOOR DEMO PLAN
SCALE: 1/4" = 1'
GENERAL SITE PREP & DEMO NOTES
Install plastic to seal off areas being remodeled
from rest of home as necessary.
Install floor covering for construction path from
door designated as the construction entrance to
locations of remodeling as necessary.
Install additional floor covering or wall protection
as needed over areas close to the areas of
construction activity.
Install dust control measures on HVAC cold air
returns located within the locations of
remodeling.
Custom Living can provide a HEPA Air Scrubber
to aid in airborne dust control from the start of
demolition up to priming of new drywall
depending on site conditions. Homeowner
understands that this will help to reduce airborne
dust; however, it will not mitigate it in its entirety.
Demolition Contractor(s) are responsible for all
labor, for the scope of work specified in the
drawings provided by Custom Living.
Homeowner understands that Custom Living has
only provided a labor and material allowance for
the scope of demolition denoted on the
drawings. Any additional scope added or
uncovered during demolition result in filing a
Change Order during construction.
Homeowners understand that demolition work
will generate dust and noise throughout the
house. Custom Living will provide site protection
measures to reduce where possible, but
Homeowners should not expect 100%
containment.
N
11/08/21