Loading...
HomeMy WebLinkAboutS101.1DN SB2421 SB24213DB1021 SB3721 SB3721 SB2421 SB2421 3DB1021 SB3721 SB3721 1623 D04 D02 D02 D03 D03 D04 D04 D01D01 D02 D02 FLOOR FLOOR CEILING CEILING CEILING FLOOR cL cL cL cL cL cL cL cL cL GFCI R R CO/SD SD SD SD R GFCI R GFCI R 56'-8 1/8"2'-8"8'-4 1/2"13'-8 1/2"6'-11" 3'-7 3/4"11' 5' 11'-0 3/4" 15'-0 1/4" 12'-4 1/4"10'9'-5 1/2"5' 7'-1" 10' 6'-8 1/2" 10' 8' 1'-7" 1'-7 1/4" 10'-4"1'-6"8'-10" 1'-8 1/2"1'-8 1/2" 5' 17'-3" OPEN BELOW J/J BATH 8'0" CH AFF CARPET 8'0" CH AFF CARPET 8'0" CH AFF CARPET CLOSET BEDROOM 1 8'0" CH AFF CARPET BATH CLOSET CLOSET BATH MASTER BATH 8'0" CH AFF TILE Shelving CLOSET HALL 8'0" CH AFF CARPET I1I1 I2I2 D2D2 D3D3 D4D4 D1D1 D5D5 ATTIC STORAGE 8'0" CH AFF CARPET BEDROOM 2 BEDROOM 3 ATTIC CHASEOPEN STORAGE OPEN STORAGE FRAMING PLAN NOTES NOTE QTY DESCRIPTION 1 RE-FRAME AS REQUIRED FROM FIRE DAMAGE 1 FRAME NEW SCISSOR TRUSS ROOF DECKING 1 FRAME NEW NON-LOAD BEARING INTERIOR WALLS AS SHOWN ON PLAN. F1F1 F2F2 F3F3 F1F1 F2F2 F3F3 INSULATION PLAN NOTES NOTE QTY DESCRIPTION 1 FOAM AND FIRE CAULK ALL NEW WALLS TO MEET MUNICIPAL FIRE CODE REQUIREMENTS. FINAL INSULATION SCOPE TO BE DETERMINED ON A FIELD WALK FOLLOWING MECHANICAL ROUGH-INS. 1 PROVIDE AND INSTALL EXTERIOR WALL AND ATTIC INSULATION PER CODE. I1I1 I2I2 I1I1 I2I2 DRYWALL PLAN NOTES NOTE QTY DESCRIPTION 1 ALL NEW DRYWALL ON WALLS AND CEILING AS REQUIRED FOR NEW ADDITION. 1 INSTALL DRYWALL ON NEW FRAMED WALLS. MATCH EXISTING FINISH LEVEL. 1 PATCH AND REPAIR CEILING DRYWALL AS NEEDED BY DEMO 1 PATCH AND REPAIR DRYWALL AS NEEDED FROM CABINET REMOVAL. 1 REFRAME AND PATCH WALL AS NEEDED FROM DEMO D1D1 D2D2 D3D3 D4D4 D5D5 D1D1 D2D2 D3D3 D4D4 D5D5 DOOR SCHEDULE NUMBER FLOOR QTY R/O TOP WIDTH HEIGHT DESCRIPTION SUPPLIER D01 2 2 62"X82 1/2" 80" 60 " 80 " DOUBLE HINGED-PANEL D02 2 4 32"X82 1/2" 80" 30 " 80 " HINGED-PANEL D03 2 2 34 1/2"X82 1/2" 80" 32 1/2 " 80 " HINGED-PANEL D04 2 3 26"X82 1/2" 80" 24 " 80 " HINGED-PANEL EXISTING 2X4 FRAMING DEMOLITION & FRAMING KEY NO DEMO IN THIS ROOM EXISTING 2X6 FRAMING WALL SECTION TO BE REMOVED NEW 2x4 FRAMING NEW 2X6 FRAMING BULK HEAD / LOWERED CEILING SELVIO RESIDENCEFIRE RESTORATION3208 Maralice Dr.Carmel IN 46033Date:Revision : A8 SHEET OF 18 SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 4622010/27/2021 DATE : [PRINTS TO SCALE IF PRINTED ON 24" X 36" ] DESIGNER: JONNI BERKLEYE: jonni@customlivingusa.comC: 317-801-3073PROPOSED 2ND FLOOR PLAN SCALE: 1/4" = 1' GENERAL PROPOSED PLAN NOTES Framing contractors are responsible for all labor, for the scope of work specified on the drawings provided by Custom Living. Owner understands that Custom Living has only provided a labor and material allowance for the scope of Rough Carpentry work specified on the drawings. Any additional work added or uncovered during this scope will be filed as a Change Orde r during construction Owner understands that the drywall allowance is based on an estimated board count and square footage take-off. A final walk through with a drywall contractor after framing and mechanical rough-ins will be necessary to finalize drywall installation and finish budgets. Final drywall touch-ups will follow countertop installation. N 11/08/21