HomeMy WebLinkAboutC070.0 Utility DetailsPLAN VIEW SECTION Gravel Backfill shall extend at least 3 feet [914 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) 1:50 SCEDrawn By: AF-X.2 STDDocument: STORMWATER TREATMENT SOLUTIONS 06/16/11Date: Phone (888) 344-9044 Fax (423) 826-2112 www.aquashieldinc.com 2705 Kanasita Drive, Chattanoooga, TN 37343Scale: Aqua-Filter Filtration System Model AF-X.2 Off-Line Standard DetailU.S. Patent No. 6524473 and other Patent Pending Pipe coupling by Contractor. 12" [305 mm] long Stub-out by Manufacturer. A Hinged Center Panel B B C C Outlet Ladder Plan View Anchor Panel *Example Aqua-Swirl - Download AquaSwirl Detail Drawing for More Information. **See Site Plan for actual system orientation. Section A-A Grade (Rim) Undisturbed Soils Bedding Manhole Frame and Cover on All risers by Manufacturer. (See Detail) Section B-B Section C-C 4 1/2" [114 mm] 1/2" [13 mm] 1" [25 mm] Manhole Frame & Cover Detail NTS For Non-Traffic Areas Only Soil 1" [25 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Soil Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Riser Frame Cover 48" [1219 mm] Min. 12" [305 mm] Wrap Compressible Expansion Joint Material to a minimum 1-inch [25 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Backfill (90% Proctor Density) Concrete Concrete8" [203 mm] Gravel Backfill Gravel Backfill * * Hinged Center Panel 3 Evenly Spaced Distribution Slots Filter MediaAnchor Panel Feet Anchor Panel Feet Ladder Riser Filter Outlet Bedding Bedding Bedding Undisturbed Soils Hinged Center Panel Bedding Bedding Bedding Undisturbed Soils Filter Media 3 Evenly Spaced Distribution Slots Flow Control Orifice STORMWATER TREATMENT SOLUTIONS Phone (888) 344-9044 www.aquashieldinc.com ™ A 4 1/2"Cover Frame 1" Thick Expansion Joint Material30" Riser #4 Rebar @ 6" Each Way 14" 48" 1/2" 3,000 psi (min) Concrete Manhole Frame & Cover Detail For Traffic Loading Areas NTS If traffic loading (H-20) is required or anticipated, a 4-foot diameter, 14-inch thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1-inch thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi and be reinforced with #4 reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch. Top of manhole cover and concrete slab shall be level with finish grade. Backfill (90% Proctor Density) * Please see accompanied Aqua-Swirl specification notes. * See Site Plan for actual system orientation. ** Orientation may vary from 90°, 180°, or custom angles to meet site conditions. Aqua-Swirl Concentrator Model AS-2 PCS Standard DetailDate:02/05/15 Scale: Document: Drawn By: AS-2 PCS STD 1:20 JCW U.S. Patent No. 6524473 and other Patent Pending ™ Phone (888) 344-9044 Fax (423) 826-2112 www.aquashieldinc.com STORMWATER TREATMENT SOLUTIONS Pipe coupling by Contractor. 12" long Stub-out by Manufacturer. Plan ViewInlet Outlet A Vent Arched Baffle Octagonal Base Plate A Pipe coupling by Contractor. 12" long Stub-out by Manufacturer. Vent Arched Baffle Riser Gravel Backfill shall extend at least 3 feet [914 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) Swirl Inlet Swirl Outlet Bedding Undisturbed Soil Backfill Section A-A Grade (Rim) Rim elevations to match finished grade. PCS risers should NOT be field cut by Contractor. Manhole Frame and Cover by Manufacturer. (See Details) 4 1/2" [114 mm] 1/2" [13 mm] 1" [25 mm] Manhole Frame & Cover Detail NTS For Non-Traffic Areas Only Soil 1" [25 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Soil Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Riser Frame Cover 48" [1219 mm] Min. 12" [305 mm] Wrap Compressible Expansion Joint Material to a minimum 1-inch [25 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Backfill (90% Proctor Density) Concrete Concrete 8" [203 mm] Gravel Backfill Gravel Backfill 4 1/2"Cover Frame 1" [25 mm] Thick Expansion Joint Material30" [762 mm] Riser #4 [13 mm] Rebar @ 6" [152 mm] Each Way 14"1/2" 3,000 psi [20 MPa] (min) Concrete Manhole Frame & Cover Detail For Traffic Loading Areas NTS If traffic loading (HS-25) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1-inch [25 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade. Backfill (90% Proctor Density) 48" STORMWATER TREATMENT SOLUTIONS Phone (888) 344-9044 www.aquashieldinc.com ™ Aqua-Swirl Polymer Coated Steel (PCS) Stormwater Treatment System Note: As an alternative, 42-inch OD, HS-25 rated precast concrete rings may be substituted. 14-inch thickness must be maintained. 2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343 UTILITY DETAILS C106TOTAL ENGINEERING SOLUTIONS COMPANY, LLCNEW CONVENIENCE STORE/ FOODMART2425 HARLESTON DRIVECARMEL, INDIANA 46032210439955 Crosspoint Blvd., Suite 100p (317) 537-2410www.tesco-solutions.comIndianapolis, IN 4625611.16.21