1GO - Trusses
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by 84 Components - 0783. October 28,2021 Liu, Xuegang Pages or sheets covered by this seal: I48559002 thru I48559097 My license renewal date for the state of Indiana is July 31, 2022. 26663A 1GO JORDAN RES IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss A01 Truss Type Half Hip Girder Qty 1 Ply 2 1GO JORDAN RES Job Reference (optional) I48559002 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:09 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-mEplNKQq2GLTR?MFGdQRSJMY_kIgB6OEjRuJqHyOyi0 Scale = 1:74.3 12 3 4 5 678910 11 12 13 14 25 24 23 22 21 20 19 18 17 16 15 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 6x8 3x6 4x8 3x6 4x8 3x6 4x8 3x6 3x4 4x4 4x4 3x4 4x4 3x4 1.5x4 4x8 3x4 4x4 3x4 4x6 4x6 6x6 3x6 4x8 4-8-04-8-0 9-0-84-4-8 13-11-134-11-5 18-9-64-9-9 23-6-154-9-9 28-4-84-9-9 33-2-24-9-9 37-11-114-9-9 42-11-04-11-5 -1-2-8 1-2-8 4-8-0 4-8-0 9-0-8 4-4-8 13-11-13 4-11-5 18-9-6 4-9-9 23-6-15 4-9-9 28-4-8 4-9-9 33-2-2 4-9-9 37-11-11 4-9-9 42-11-0 4-11-5 0-10-147-8-49.00 12 Plate Offsets (X,Y)-- [2:0-4-8,0-2-0], [5:0-6-0,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.58 0.19 0.56 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.17 -0.25 0.05 (loc) 20 20-21 15 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 594 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 2-10-8 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-14. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 15=0-3-8, 2=0-3-8 Max Horz 2=205(LC 7) Max Uplift 15=-1128(LC 10), 2=-998(LC 10) Max Grav 15=3413(LC 33), 2=3355(LC 33) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-4620/1440, 4-5=-4267/1444, 5-6=-4441/1558, 6-7=-4952/1744, 7-8=-4958/1755, 8-10=-4958/1755, 10-11=-4505/1596, 11-13=-3545/1263, 13-14=-2083/759, 14-15=-3279/1147 BOT CHORD 2-25=-1167/3563, 24-25=-1167/3563, 23-24=-1170/3445, 21-23=-1521/4471, 20-21=-1704/4983, 18-20=-1559/4527, 17-18=-1232/3547, 16-17=-731/2069 WEBS 4-25=-60/321, 5-24=-116/567, 5-23=-658/1872, 6-23=-1311/545, 6-21=-341/972, 7-21=-526/263, 8-20=-490/254, 10-20=-290/841, 10-18=-1208/515, 11-18=-607/1786, 11-17=-1998/789, 13-17=-919/2704, 13-16=-2814/1074, 14-16=-1259/3707 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1128 lb uplift at joint 15 and 998 lb uplift at joint 2. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.Continued on page 2 October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss A01 Truss Type Half Hip Girder Qty 1 Ply 2 1GO JORDAN RES Job Reference (optional) I48559002 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:10 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-EQN7bfRSpaTK29xRqLyg?Xvjk8evwZeOy5dtNjyOyi? NOTES- 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 126 lb down and 119 lb up at 9-0-7, 126 lb down and 114 lb up at 11-1-4, 126 lb down and 114 lb up at 13-1-4, 126 lb down and 114 lb up at 15-1-4, 126 lb down and 114 lb up at 17-1-4, 126 lb down and 114 lb up at 19-1-4, 126 lb down and 114 lb up at 21-1-4, 126 lb down and 114 lb up at 23-1-4, 126 lb down and 114 lb up at 25-1-4, 133 lb down and 126 lb up at 27-1-4, 133 lb down and 126 lb up at 29-1-4, 133 lb down and 126 lb up at 31-1-4, 133 lb down and 126 lb up at 33-1-4, 133 lb down and 126 lb up at 35-1-4, 133 lb down and 126 lb up at 37-1-4, and 133 lb down and 126 lb up at 39-1-4, and 133 lb down and 126 lb up at 41-1-4 on top chord, and 203 lb down and 71 lb up at 3-1-4, 188 lb down and 80 lb up at 5-1-4, 203 lb down and 111 lb up at 7-1-4, 63 lb down and 39 lb up at 9-1-4, 63 lb down and 39 lb up at 11-1-4, 63 lb down and 39 lb up at 13-1-4, 63 lb down and 39 lb up at 15-1-4, 63 lb down and 39 lb up at 17-1-4, 63 lb down and 39 lb up at 19-1-4, 63 lb down and 39 lb up at 21-1-4, 63 lb down and 39 lb up at 23-1-4, 63 lb down and 39 lb up at 25-1-4, 63 lb down and 25 lb up at 27-1-4, 63 lb down and 25 lb up at 29-1-4, 63 lb down and 25 lb up at 31-1-4, 63 lb down and 25 lb up at 33-1-4, 63 lb down and 25 lb up at 35-1-4, 63 lb down and 25 lb up at 37-1-4, and 63 lb down and 25 lb up at 39-1-4, and 63 lb down and 25 lb up at 41-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-5=-60, 5-14=-60, 2-15=-20 Concentrated Loads (lb) Vert: 5=-83(F) 9=-83(F) 24=-31(F) 11=-94(F) 17=-31(F) 12=-94(F) 19=-31(F) 26=-83(F) 27=-83(F) 28=-83(F) 29=-83(F) 31=-83(F) 32=-83(F) 33=-83(F) 34=-94(F) 35=-94(F) 37=-94(F) 38=-94(F) 39=-94(F) 40=-94(F) 41=-203(F) 42=-188(F) 43=-188(F) 44=-31(F) 45=-31(F) 46=-31(F) 47=-31(F) 48=-31(F) 49=-31(F) 50=-31(F) 51=-31(F) 53=-31(F) 54=-31(F) 55=-31(F) 57=-31(F) 58=-31(F) 60=-31(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss A02 Truss Type Half Hip Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559003 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:11 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-idxVo?S4atbBgJWeO2TvXkSqEXtmf_WXBlNQv9yOyi_ Scale = 1:87.0 1 2 3 4 5 678910 11 12 13 22 21 20 19 18 17 16 15 14 23 24 25 26 27 28 29 30 31 32 33 6x6 6x6 3x8 MT18HS 6x8 4x6 4x6 4x6 3x4 3x4 4x8 4x6 4x6 6x6 4x6 6-2-106-2-10 12-1-135-11-2 19-3-27-1-5 26-2-106-11-9 33-2-36-11-9 40-1-116-11-9 47-3-07-1-5 -1-2-8 1-2-8 6-2-10 6-2-10 12-1-13 5-11-2 19-3-2 7-1-5 26-2-10 6-11-9 33-2-3 6-11-9 40-1-11 6-11-9 47-3-0 7-1-5 0-10-149-9-1510-0-49-9-159.00 12 Plate Offsets (X,Y)-- [12:0-3-0,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.85 0.60 0.64 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.20 -0.39 0.12 (loc) 18-19 18-19 14 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 265 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 *Except* 13-14: 2x4 SPF 1650F 1.5E SLIDER Left 2x6 SP 2400F 2.0E 3-11-6 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-1-9 max.): 6-13. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 13-14, 7-19, 8-18, 10-16, 11-15 REACTIONS. (size) 14=0-3-8, 2=0-3-8 Max Horz 2=265(LC 13) Max Grav 14=2072(LC 20), 2=2014(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2742/114, 4-6=-2436/182, 6-7=-2452/199, 7-8=-2481/191, 8-10=-2481/191, 10-11=-2123/176, 11-13=-1346/151, 13-14=-1931/139 BOT CHORD 2-22=-336/2117, 21-22=-336/2117, 19-21=-257/1961, 18-19=-242/2489, 16-18=-176/2147, 15-16=-128/1337 WEBS 4-21=-282/107, 6-21=0/368, 6-19=-37/974, 7-19=-597/117, 8-18=-412/99, 10-18=-66/632, 10-16=-900/144, 11-16=-81/1381, 11-15=-1501/194, 13-15=-113/2208 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=47ft; eave=6ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 3-6-3, Interior(1) 3-6-3 to 12-1-13, Exterior(2) 12-1-13 to 18-10-0, Interior(1) 18-10-0 to 47-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) All plates are 3x6 MT20 unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss A03 Truss Type Piggyback Base Qty 2 Ply 1 1GO JORDAN RES Job Reference (optional) I48559004 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:13 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-e?3FDhTL6Vsvvcg0VTVNc9XAGLZN7ueqe3sXy2yOyhy Scale = 1:83.8 1 2 3 4 5 678910 11 12 13 22 21 20 19 18 17 16 15 14 23 24 25 26 27 28 29 30 31 32 33 34 5x12 MT18HS 6x6 3x8 MT18HS 6x8 4x6 4x6 4x6 3x4 3x4 6x8 4x6 6x6 4x6 6-2-106-2-10 12-1-135-11-2 19-3-27-1-5 26-2-106-11-9 33-2-36-11-9 40-1-116-11-9 47-3-07-1-5 -1-2-8 1-2-8 6-2-10 6-2-10 12-1-13 5-11-2 19-3-2 7-1-5 26-2-10 6-11-9 33-2-3 6-11-9 40-1-11 6-11-9 47-3-0 7-1-5 0-10-1410-0-49.00 12 Plate Offsets (X,Y)-- [6:0-9-12,0-1-12], [12:0-3-0,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.88 0.59 0.67 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.20 -0.38 0.12 (loc) 16-18 16-18 14 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 267 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 *Except* 13-14: 2x4 SPF 1650F 1.5E SLIDER Left 2x6 SP 2400F 2.0E 3-11-6 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-2-2 max.): 6-13. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 13-14, 7-19, 8-16, 10-16, 11-15 REACTIONS. (size) 14=0-3-8, 2=0-3-8 Max Horz 2=270(LC 11) Max Grav 14=2072(LC 20), 2=2025(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2763/113, 4-6=-2442/182, 6-7=-2427/198, 7-8=-2465/192, 8-10=-2078/177, 10-11=-2078/177, 11-13=-1322/152, 13-14=-1931/140 BOT CHORD 2-22=-342/2136, 21-22=-342/2136, 19-21=-261/1963, 18-19=-244/2467, 16-18=-216/2504, 15-16=-129/1312 WEBS 4-21=-307/107, 6-21=0/385, 6-19=-36/921, 7-19=-569/114, 8-16=-692/67, 10-16=-409/102, 11-16=-82/1364, 11-15=-1496/196, 13-15=-115/2193 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=47ft; eave=6ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 3-6-3, Interior(1) 3-6-3 to 12-1-13, Exterior(2) 12-1-13 to 18-10-0, Interior(1) 18-10-0 to 47-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 3x6 MT20 unless otherwise indicated. 7) The Fabrication Tolerance at joint 6 = 8% 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss A03A Truss Type Piggyback Base Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559005 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:14 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-6CceQ1Uzto_mXmFD3A0c9N3I8lubsLt_tjb4VUyOyhx Scale = 1:82.9 1 2 3 4567891011 20 19 18 17 16 15 14 13 12 21 22 23 24 25 26 27 28 29 30 31 32 336x8 4x6 4x6 8x8 6x6 3x8 MT18HS4x6 3x4 3x4 6x8 4x6 6x6 4x6 6-2-106-2-10 12-1-135-11-2 19-3-27-1-5 26-2-106-11-9 33-2-36-11-9 40-1-116-11-9 47-3-07-1-5 6-2-10 6-2-10 12-1-13 5-11-2 19-3-2 7-1-5 26-2-10 6-11-9 33-2-3 6-11-9 40-1-11 6-11-9 47-3-0 7-1-5 0-10-1410-0-49.00 12 Plate Offsets (X,Y)-- [4:0-4-8,0-1-12], [10:0-3-0,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 1.00 0.59 0.67 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.20 -0.38 0.12 (loc) 14-16 14-16 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 266 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 *Except* 11-12: 2x4 SPF 1650F 1.5E SLIDER Left 2x6 SP 2400F 2.0E 3-11-6 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-2-1 max.): 4-11. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 11-12, 5-17, 6-14, 8-14, 9-13 REACTIONS. (size) 1=0-3-8, 12=0-3-8 Max Horz 1=266(LC 11) Max Grav 1=1959(LC 19), 12=2073(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-2769/123, 3-4=-2463/189, 4-5=-2430/202, 5-6=-2466/195, 6-8=-2079/179, 8-9=-2079/179, 9-11=-1322/153, 11-12=-1932/141 BOT CHORD 1-20=-343/2143, 19-20=-343/2143, 17-19=-261/1966, 16-17=-245/2469, 14-16=-216/2506, 13-14=-129/1312 WEBS 3-19=-311/108, 4-19=0/388, 4-17=-35/921, 5-17=-569/113, 6-14=-693/67, 8-14=-409/102, 9-14=-83/1365, 9-13=-1497/196, 11-13=-115/2194 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=47ft; eave=6ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 4-8-11, Interior(1) 4-8-11 to 12-1-13, Exterior(2) 12-1-13 to 18-10-0, Interior(1) 18-10-0 to 47-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) All plates are 3x6 MT20 unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss A04 Truss Type Piggyback Base Qty 3 Ply 1 1GO JORDAN RES Job Reference (optional) I48559006 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:15 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-aOA0eNVbe66c9wqPduXriacUD9Gvbrg76NLe1wyOyhw Scale = 1:72.3 1 23456789 18 17 16 15 14 13 12 11 10 19 20 21 22 23 24 25 26 27 28 29 6x8 3x6 4x8 3x4 3x4 3x6 6x6 4x8 3x4 3x4 3x4 1.5x4 4x8 3x4 6x6 4x6 4x6 3x6 2-1-132-1-13 9-3-27-1-5 16-2-106-11-9 23-2-36-11-9 30-1-116-11-9 37-3-07-1-5 2-1-13 2-1-13 9-3-2 7-1-5 16-2-10 6-11-9 23-2-3 6-11-9 30-1-11 6-11-9 37-3-0 7-1-5 8-4-1410-0-49.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-12], [2:0-6-0,0-2-0], [8:0-3-0,Edge], [10:Edge,0-1-8], [16:0-3-8,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.92 0.45 0.50 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.13 -0.25 0.04 (loc) 12-14 12-14 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 235 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (5-6-0 max.): 2-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-17, 3-16, 4-14, 4-12, 6-12, 7-11, 1-18 2 Rows at 1/3 pts 9-10 REACTIONS. (size) 10=0-3-8, 18=0-3-8 Max Horz 18=250(LC 11) Max Grav 10=1650(LC 19), 18=1614(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-535/144, 2-3=-1220/107, 3-4=-1557/93, 4-6=-1482/112, 6-7=-1482/112, 7-9=-1024/120, 9-10=-1510/131, 1-18=-1643/71 BOT CHORD 17-18=-265/273, 16-17=-244/438, 14-16=-231/1261, 12-14=-205/1598, 11-12=-124/1007 WEBS 2-17=-1157/188, 2-16=-87/1453, 3-16=-918/156, 3-14=-46/638, 4-14=-325/120, 6-12=-409/102, 7-12=-78/845, 7-11=-1090/189, 9-11=-106/1676, 1-17=-98/1415 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=37ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 7-5-0, Interior(1) 7-5-0 to 37-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss A05 Truss Type Piggyback Base Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559007 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:16 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-2akOrjWDPQETm4PbBb34Eo9lAYeCKLqGL14BZNyOyhv Scale = 1:58.6 1 23456 12 11 10 987 13 14 15 16 17 18 19 4x8 3x4 4x6 3x4 3x4 3x4 4x4 4x8 1.5x4 3x4 4x4 4x6 2-1-132-1-13 9-0-26-10-5 15-8-116-8-9 22-7-06-10-5 2-1-13 2-1-13 9-0-2 6-10-5 15-8-11 6-8-9 22-7-0 6-10-5 8-4-1410-0-49.00 12 Plate Offsets (X,Y)-- [2:0-6-0,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.52 0.32 0.32 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.07 -0.13 0.01 (loc) 7-8 7-8 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 153 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-7, 2-11, 3-9, 5-8, 1-12 REACTIONS. (size) 7=Mechanical, 12=0-3-8 Max Horz 12=250(LC 11) Max Uplift 7=-91(LC 11), 12=-36(LC 10) Max Grav 7=1026(LC 19), 12=971(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-347/139, 2-3=-579/81, 3-5=-579/82, 5-6=-545/99, 6-7=-891/148, 1-12=-995/76 BOT CHORD 11-12=-290/297, 9-11=-257/379, 8-9=-146/547 WEBS 2-11=-623/196, 2-9=-95/655, 3-9=-429/126, 5-8=-518/208, 6-8=-130/910, 1-11=-108/868 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 6-4-11, Interior(1) 6-4-11 to 22-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 91 lb uplift at joint 7 and 36 lb uplift at joint 12. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss B01 Truss Type Half Hip Girder Qty 1 Ply 2 1GO JORDAN RES Job Reference (optional) I48559008 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:19 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-T9QXUkY6iLc2dY7AskcnsQnBzmhVXYHj1?JrAhyOyhs Scale = 1:74.8 12 3 4 5 6 7891011 12 21 20 19 18 17 16 15 14 13 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 3839 40 3x6 6x8 3x6 6x8 4x8 6x8 4x8 4x8 3x6 3x4 4x4 3x6 4x4 4x4 3x4 1.5x4 6x8 6x6 6x6 4x8 4-10-114-10-11 9-5-154-7-3 14-1-24-7-3 20-3-126-2-9 26-4-96-0-13 32-5-76-0-13 38-8-06-2-9 -1-2-8 1-2-8 4-10-11 4-10-11 9-5-15 4-7-3 14-1-2 4-7-3 20-3-12 6-2-9 26-4-9 6-0-13 32-5-7 6-0-13 38-8-0 6-2-9 0-10-1411-5-129.00 12 Plate Offsets (X,Y)-- [2:0-5-0,0-1-0], [7:0-6-0,0-2-0], [13:Edge,0-3-8], [14:0-2-0,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.87 0.28 0.91 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.14 -0.23 0.05 (loc) 17-19 17-19 13 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 579 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF No.2 *Except* 12-13: 2x4 SPF 1650F 1.5E SLIDER Left 2x4 SPF No.2 3-0-3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-4-14 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-12. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 12-13, 8-15, 11-14 REACTIONS. (size) 13=Mechanical, 2=0-3-8 Max Horz 2=308(LC 7) Max Uplift 13=-1649(LC 7), 2=-1137(LC 10) Max Grav 13=5311(LC 33), 2=4624(LC 33) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-6361/1633, 4-6=-5852/1649, 6-7=-5190/1578, 7-8=-4463/1427, 8-9=-3878/1269, 9-11=-3878/1269, 11-12=-2493/845, 12-13=-4600/1411 BOT CHORD 2-21=-1387/4953, 20-21=-1387/4953, 19-20=-1399/4760, 17-19=-1286/4167, 15-17=-1410/4509, 14-15=-818/2482 WEBS 4-21=-29/648, 4-20=-384/11, 6-20=-215/1122, 6-19=-1209/286, 7-19=-643/2201, 7-17=-316/797, 8-17=-333/771, 8-15=-1245/337, 9-15=-347/68, 11-15=-898/2986, 11-14=-2955/880, 12-14=-1561/5093 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=39ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Refer to girder(s) for truss to truss connections. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1649 lb uplift at joint 13 and 1137 lb uplift at joint 2.Continued on page 2 October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss B01 Truss Type Half Hip Girder Qty 1 Ply 2 1GO JORDAN RES Job Reference (optional) I48559008 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:19 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-T9QXUkY6iLc2dY7AskcnsQnBzmhVXYHj1?JrAhyOyhs NOTES- 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 316 lb down and 61 lb up at 2-1-14, 322 lb down and 63 lb up at 4-1-14, 322 lb down and 80 lb up at 6-1-14, 322 lb down and 101 lb up at 8-1-14, 322 lb down and 128 lb up at 10-1-14, 350 lb down and 158 lb up at 12-1-14, 369 lb down and 182 lb up at 14-1-14, 351 lb down and 182 lb up at 16-1-14, 366 lb down and 182 lb up at 18-1-14, 370 lb down and 182 lb up at 20-1-14, 351 lb down and 182 lb up at 22-1-14, 365 lb down and 182 lb up at 24-1-14, 381 lb down and 182 lb up at 26-1-14, 372 lb down and 182 lb up at 28-1-14, 351 lb down and 182 lb up at 30-1-14, 369 lb down and 181 lb up at 32-1-14, 379 lb down and 181 lb up at 34-1-14, and 356 lb down and 181 lb up at 36-1-14, and 372 lb down and 175 lb up at 38-1-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-7=-60, 7-12=-60, 2-13=-20 Concentrated Loads (lb) Vert: 18=-322(B) 19=-322(B) 17=-322(B) 15=-322(B) 14=-329(B) 24=-316(B) 25=-322(B) 26=-322(B) 27=-322(B) 28=-322(B) 30=-322(B) 31=-322(B) 32=-322(B) 33=-322(B) 34=-322(B) 36=-322(B) 37=-329(B) 39=-329(B) 40=-335(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss B02 Truss Type Piggyback Base Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559009 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:20 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-xL_vh4ZkTekvFhiMQR70PeJLmAz8G5bsFf2Pi8yOyhr Scale = 1:70.1 12 3 4 5 678910 11 19 18 17 16 15 14 13 12 20 21 22 23 24 25 26 27 3x6 6x8 3x6 6x6 3x4 4x8 4x4 4x4 3x6 3x6 1.5x4 3x4 3x4 3x4 1.5x4 4x8 4x4 6x6 3x6 6-2-106-2-10 12-1-135-11-2 18-10-46-8-7 25-4-146-6-11 31-11-96-6-11 38-8-06-8-7 -1-2-8 1-2-8 6-2-10 6-2-10 12-1-13 5-11-2 18-10-4 6-8-7 25-4-14 6-6-11 31-11-9 6-6-11 38-8-0 6-8-7 0-10-1410-0-49.00 12 Plate Offsets (X,Y)-- [2:0-6-0,0-0-1], [6:0-6-0,0-2-0], [12:Edge,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.93 0.45 0.52 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.12 -0.23 0.07 (loc) 14-16 14-16 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 223 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 SLIDER Left 2x6 SP 2400F 2.0E 3-11-6 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-15 oc purlins, except end verticals, and 2-0-0 oc purlins (5-3-6 max.): 6-11. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-16, 7-14, 8-14, 10-13 2 Rows at 1/3 pts 11-12 REACTIONS. (size) 12=Mechanical, 2=0-3-8 Max Horz 2=270(LC 11) Max Grav 12=1690(LC 20), 2=1636(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2167/90, 4-6=-1853/159, 6-7=-1660/170, 7-8=-1480/160, 8-10=-1480/160, 10-11=-996/143, 11-12=-1558/132 BOT CHORD 2-19=-311/1685, 18-19=-311/1685, 16-18=-233/1475, 14-16=-206/1701, 13-14=-123/990 WEBS 4-18=-336/103, 6-18=0/399, 6-16=-21/483, 7-16=-264/96, 7-14=-334/68, 8-14=-375/91, 10-14=-81/943, 10-13=-1175/189, 11-13=-109/1713 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=39ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 2-7-14, Interior(1) 2-7-14 to 12-1-13, Exterior(2) 12-1-13 to 17-7-7, Interior(1) 17-7-7 to 38-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss B03 Truss Type Piggyback Base Qty 4 Ply 1 1GO JORDAN RES Job Reference (optional) I48559010 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:21 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-PYYHuQaMEysmtrHZz9eFxrseRZFJ?V50UJoyEayOyhq Scale = 1:60.0 1 2 3 4 5 6 78910 15 14 13 12 11 16 17 18 19 20 21 22 3x4 4x6 3x6 3x4 3x6 4x8 4x4 4x4 4x4 3x6 1.5x4 4x8 3x4 3x4 3x4 6-2-106-2-10 12-1-135-11-2 21-2-109-0-14 30-7-09-4-6 -1-2-8 1-2-8 6-2-10 6-2-10 12-1-13 5-11-2 18-2-6 6-0-9 24-2-15 6-0-9 30-7-0 6-4-1 0-10-1410-0-49.00 12 Plate Offsets (X,Y)-- [2:0-6-0,0-0-1], [6:0-4-0,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.42 0.71 0.76 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.26 -0.44 0.04 (loc) 11-12 11-12 11 l/defl >999 >828 n/a L/d 240 180 n/a PLATES MT20 Weight: 168 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 SLIDER Left 2x6 SP 2400F 2.0E 3-11-6 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-12 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 10-11, 7-14, 7-12, 8-11 REACTIONS. (size) 11=Mechanical, 2=0-3-8 Max Horz 2=270(LC 11) Max Uplift 11=-34(LC 11) Max Grav 11=1327(LC 20), 2=1291(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1621/71, 4-6=-1309/137, 6-7=-996/140, 7-8=-915/132 BOT CHORD 2-15=-284/1267, 14-15=-284/1267, 12-14=-175/1033, 11-12=-135/713 WEBS 4-14=-358/102, 6-14=0/429, 7-12=-393/136, 8-12=0/760, 8-11=-1264/134 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=31ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-10-3, Interior(1) 1-10-3 to 12-1-13, Exterior(2) 12-1-13 to 16-5-11, Interior(1) 16-5-11 to 30-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 34 lb uplift at joint 11. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss B04 Truss Type Piggyback Base Qty 3 Ply 1 1GO JORDAN RES Job Reference (optional) I48559011 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:22 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-tk5f6ma__G_dU?slXs9UU3Pp1zc?jz29jzXVn0yOyhp Scale = 1:58.3 1 2 3 4567 12 11 10 9 8 13 14 15 16 17 18 19 20 1.5x4 4x6 3x6 3x4 4x6 3x4 4x8 3x4 3x4 3x4 3x4 3x6 8-1-138-1-13 17-2-109-0-14 26-7-09-4-6 4-2-10 4-2-10 8-1-13 3-11-2 14-2-6 6-0-9 20-2-15 6-0-9 26-7-0 6-4-1 3-10-1410-0-49.00 12 Plate Offsets (X,Y)-- [3:0-4-0,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.43 0.68 0.66 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.27 -0.46 0.03 (loc) 8-9 8-9 8 l/defl >999 >687 n/a L/d 240 180 n/a PLATES MT20 Weight: 154 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-8, 4-11, 4-9, 5-8, 2-12 REACTIONS. (size) 8=Mechanical, 12=0-3-8 Max Horz 12=259(LC 11) Max Uplift 8=-67(LC 11) Max Grav 8=1179(LC 19), 12=1140(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-950/122, 3-4=-723/119, 4-5=-779/125 BOT CHORD 11-12=-291/663, 9-11=-186/849, 8-9=-143/619 WEBS 2-11=-1/267, 3-11=0/287, 4-11=-255/49, 5-9=-7/604, 5-8=-1084/143, 2-12=-1061/67 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=27ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 8-1-13, Exterior(2) 8-1-13 to 12-4-11, Interior(1) 12-4-11 to 26-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 67 lb uplift at joint 8. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss B05 Truss Type Piggyback Base Qty 3 Ply 1 1GO JORDAN RES Job Reference (optional) I48559012 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:23 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-Lwf1J6bclZ6U69Rx5Zhj0GxytN07SNaIydH3JTyOyho Scale = 1:58.6 1 2 345 10 9 8 7 6 11 12 13 14 15 16 17 1.5x4 4x8 3x4 3x4 3x4 3x4 1.5x4 4x8 4x6 3x6 8-1-138-1-13 15-4-67-2-10 22-7-07-2-10 4-2-10 4-2-10 8-1-13 3-11-2 15-4-6 7-2-10 22-7-0 7-2-10 3-10-1410-0-49.00 12 Plate Offsets (X,Y)-- [3:0-6-0,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.55 0.43 0.89 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.13 -0.24 0.01 (loc) 9-10 9-10 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 134 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-6, 3-7, 4-7 REACTIONS. (size) 6=Mechanical, 10=0-3-8 Max Horz 10=259(LC 11) Max Uplift 6=-91(LC 11) Max Grav 6=1012(LC 19), 10=961(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-760/120, 3-4=-547/135, 4-5=-546/135, 5-6=-866/153 BOT CHORD 9-10=-287/573, 7-9=-210/613 WEBS 4-7=-504/154, 5-7=-137/894, 2-10=-863/67 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 8-1-13, Exterior(2) 8-1-13 to 12-4-11, Interior(1) 12-4-11 to 22-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 91 lb uplift at joint 6. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss C01 Truss Type Piggyback Base Structural Gable COMMON Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559013 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:25 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-IJnokodsHBMCMTbKC_jC6h1LuBhvwS?bPwm9OLyOyhm Scale = 1:67.0 1 2 345 6 7 15 14 13 11 10 9 8 39 40 41 42 43 44 12 45 46 4x6 4x6 3x4 4x6 4x8 3x4 4x8 6x8 6x8 4x8 3x4 3x4 3x4 3x4 3x4 3x4 5-8-05-8-0 6-4-90-8-9 15-2-78-9-14 21-7-06-4-9 -1-2-8 1-2-8 6-4-9 6-4-9 10-9-8 4-4-15 15-2-7 4-4-15 21-7-0 6-4-9 22-9-8 1-2-8 3-0-1110-6-03-0-1110-6-014.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-5], [3:0-3-2,0-2-0], [4:0-3-4,0-2-0], [5:0-3-2,0-2-0], [6:Edge,0-1-5], [19:0-2-0,0-1-9], [29:0-1-13,0-0-12], [31:0-1-13,0-0-12], [35:0-1-13,0-0-12], [38:0-1-13,0-0-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.33 0.48 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.19 -0.29 0.01 (loc) 9-11 9-11 8 l/defl >989 >638 n/a L/d 240 180 n/a PLATES MT20 Weight: 210 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 *Except* 2-15,6-8: 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-11, 4-9 REACTIONS.All bearings 5-11-8 except (jt=length) 8=0-3-8, 12=0-3-8. (lb) - Max Horz 15=-244(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 15, 8, 13 except 12=-169(LC 19) Max Grav All reactions 250 lb or less at joint(s) 13, 14, 12 except 15=907(LC 21), 8=915(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-778/99, 3-4=-448/138, 4-5=-442/151, 5-6=-758/114, 2-15=-892/84, 6-8=-880/104 BOT CHORD 14-15=-231/258, 13-14=-231/258, 12-13=-231/258, 11-12=-231/258, 9-11=-1/531 WEBS 3-11=0/292, 5-9=0/258, 2-11=0/473, 6-9=0/459 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 6-4-9, Exterior(2) 6-4-9 to 10-9-8, Interior(1) 10-9-8 to 15-2-7, Exterior(2) 15-2-7 to 19-5-6, Interior(1) 19-5-6 to 22-9-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 8, 13 except (jt=lb) 12=169. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss C02 Truss Type Piggyback Base Qty 3 Ply 1 1GO JORDAN RES Job Reference (optional) I48559014 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:26 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-mVLAy8eV2UU3zcAWmiERevZW7a11fwaleaVjwnyOyhl Scale = 1:59.0 1 2 3 45 6 7 12 11 10 9 8 13 14 15 16 17 18 19 20 4x6 4x6 1.5x4 4x6 4x8 3x4 6x8 1.5x4 6x8 4x8 6-4-96-4-9 15-2-78-9-14 21-7-06-4-9 -1-2-8 1-2-8 6-4-9 6-4-9 10-9-8 4-4-15 15-2-7 4-4-15 21-7-0 6-4-9 22-9-8 1-2-8 3-0-1110-6-03-0-1110-6-014.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-5], [3:0-3-2,0-2-0], [5:0-3-2,0-2-0], [6:Edge,0-1-5] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.36 0.48 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.23 -0.32 0.01 (loc) 9-11 9-11 8 l/defl >999 >801 n/a L/d 240 180 n/a PLATES MT20 Weight: 130 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-11, 4-9 REACTIONS. (size) 12=0-3-8, 8=0-3-8 Max Horz 12=244(LC 13) Max Uplift 12=-15(LC 14), 8=-15(LC 14) Max Grav 12=933(LC 1), 8=933(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-747/127, 3-4=-435/159, 4-5=-435/159, 5-6=-747/127, 2-12=-881/118, 6-8=-881/118 BOT CHORD 11-12=-225/263, 9-11=-10/522 WEBS 2-11=0/455, 6-9=0/455 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 6-4-9, Exterior(2) 6-4-9 to 10-9-8, Interior(1) 10-9-8 to 15-2-7, Exterior(2) 15-2-7 to 19-5-6, Interior(1) 19-5-6 to 22-9-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 8. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss C03 Truss Type Piggyback Base Qty 2 Ply 1 1GO JORDAN RES Job Reference (optional) I48559015 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:28 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-iuTwMpfla6lmDwJvu7GvjKfrrOiV7p215u_q_gyOyhj Scale = 1:59.0 1 2 3 45 6 11 10 9 8 7 12 13 14 15 16 17 18 19 4x6 4x6 6x8 1.5x4 4x6 4x8 3x4 6x8 1.5x4 4x8 6-4-96-4-9 15-2-78-9-14 21-7-06-4-9 -1-2-8 1-2-8 6-4-9 6-4-9 10-9-8 4-4-15 15-2-7 4-4-15 21-7-0 6-4-9 3-0-1110-6-03-0-1110-6-014.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-5], [3:0-3-2,0-2-0], [5:0-3-2,0-2-0], [6:Edge,0-1-5] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.41 0.48 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.23 -0.32 0.01 (loc) 8-10 8-10 7 l/defl >999 >801 n/a L/d 240 180 n/a PLATES MT20 Weight: 128 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10, 4-8 REACTIONS. (size) 11=0-3-8, 7=0-3-8 Max Horz 11=232(LC 13) Max Uplift 11=-10(LC 14) Max Grav 11=936(LC 1), 7=849(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-749/124, 3-4=-437/157, 4-5=-439/156, 5-6=-749/112, 2-11=-884/115, 6-7=-802/82 BOT CHORD 8-10=-40/511 WEBS 2-10=0/456, 6-8=0/452 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 6-4-9, Exterior(2) 6-4-9 to 10-9-8, Interior(1) 10-9-8 to 15-2-7, Exterior(2) 15-2-7 to 19-5-6, Interior(1) 19-5-6 to 21-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss C04 Truss Type Piggyback Base Qty 5 Ply 1 1GO JORDAN RES Job Reference (optional) I48559016 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:29 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-A40Ja9gNLPtdq4u5Rqn8GXB1Go2lsGEBKYkNX6yOyhi Scale = 1:59.0 1 2 3 45 6 11 10 9 8 7 12 13 14 15 16 17 18 19 4x6 4x6 6x6 1.5x4 4x6 4x8 3x4 6x8 1.5x4 4x8 6-4-96-4-9 15-2-78-9-14 21-3-86-1-1 -1-2-8 1-2-8 6-4-9 6-4-9 10-9-8 4-4-15 15-2-7 4-4-15 21-3-8 6-1-1 3-0-1110-6-03-4-1210-6-014.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-5], [3:0-3-2,0-2-0], [5:0-3-2,0-2-0], [6:0-2-8,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.37 0.48 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.22 -0.32 0.01 (loc) 8-10 8-10 7 l/defl >999 >791 n/a L/d 240 180 n/a PLATES MT20 Weight: 128 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10, 4-8 REACTIONS. (size) 11=0-3-8, 7=Mechanical Max Horz 11=235(LC 13) Max Uplift 11=-10(LC 14) Max Grav 11=924(LC 1), 7=837(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-738/124, 3-4=-430/155, 4-5=-422/155, 5-6=-715/116, 2-11=-872/115, 6-7=-799/82 BOT CHORD 8-10=-47/499 WEBS 2-10=0/448, 6-8=-1/453 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 6-4-9, Exterior(2) 6-4-9 to 10-9-8, Interior(1) 10-9-8 to 15-2-7, Exterior(2) 15-2-7 to 19-5-6, Interior(1) 19-5-6 to 21-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss C05 Truss Type Piggyback Base Girder Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559017 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:30 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-eHahnVh?6j?USETH?YJNolkDfCVgbhaKZCTw3ZyOyhh Scale: 3/16"=1' 1 2 3 456 7 8 16 15 14 13 12 11 10 9 17 18 19 20 21 22 6x6 6x6 3x6 3x4 4x6 3x6 3x4 3x4 1.5x4 4x8 3x4 3x6 3x4 3x6 3x4 3-4-03-4-0 6-4-93-0-8 10-9-84-4-15 15-2-74-4-15 18-1-42-10-12 21-3-83-2-4 -1-2-8 1-2-8 3-4-0 3-4-0 6-4-9 3-0-8 10-9-8 4-4-15 15-2-7 4-4-15 18-1-4 2-10-12 21-3-8 3-2-4 3-0-1110-6-03-4-1210-6-014.00 12 Plate Offsets (X,Y)-- [4:0-3-0,0-1-8], [6:0-3-0,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.20 0.05 0.24 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.03 0.00 (loc) 12 12-13 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 187 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 15-16. WEBS 1 Row at midpt 5-12, 6-11 REACTIONS. (size) 16=0-3-8, 9=Mechanical Max Horz 16=233(LC 9) Max Grav 16=1208(LC 1), 9=883(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-793/27, 3-4=-749/99, 4-5=-505/96, 5-6=-505/96, 6-7=-686/114, 7-8=-607/48, 2-16=-1125/0, 8-9=-849/0 BOT CHORD 13-15=-54/558, 12-13=-33/517, 11-12=-12/431, 10-11=-3/370 WEBS 5-12=-296/81, 6-12=-39/314, 7-10=-320/24, 2-15=0/613, 8-10=0/509 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Refer to girder(s) for truss to truss connections. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 165 lb down at 2-0-12, and 165 lb down at 4-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 4-6=-60, 6-8=-60, 9-16=-20 Continued on page 2 October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss C05 Truss Type Piggyback Base Girder Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559017 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:30 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-eHahnVh?6j?USETH?YJNolkDfCVgbhaKZCTw3ZyOyhh LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 19=-165(B) 20=-165(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss D01 Truss Type Common Supported Gable Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559018 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:32 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-bfiRCBiFeKFChXdg7yLruApbB?BW3d6d0Wy17RyOyhf Scale = 1:54.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 27 26 25 24 23 22 21 20 19 18 17 16 4x4 3x4 3x4 3x4 21-11-021-11-0 -1-2-8 1-2-8 10-11-8 10-11-8 21-11-0 10-11-8 23-1-8 1-2-8 0-6-08-8-100-6-09.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.07 0.03 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 15 15 14 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 111 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-21 REACTIONS.All bearings 21-11-0. (lb) - Max Horz 2=-146(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 2, 22, 23, 25, 26, 27, 20, 19, 18, 17, 16, 14 Max Grav All reactions 250 lb or less at joint(s) 2, 21, 22, 23, 25, 26, 27, 20, 19, 18, 17, 16, 14 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) -1-2-8 to 1-9-8, Exterior(2) 1-9-8 to 10-11-8, Corner(3) 10-11-8 to 13-11-8, Exterior(2) 13-11-8 to 23-1-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 22, 23, 25, 26, 27, 20, 19, 18, 17, 16, 14. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss D02 Truss Type Common Qty 6 Ply 1 1GO JORDAN RES Job Reference (optional) I48559019 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:33 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-3rGpQXjuPeN3JhCsggs4QNMjtPReo4DnFAibgtyOyhe Scale = 1:50.6 1 2 3 4 5 6 7 10 9 8 11 12 13 14 15 16 4x6 3x4 4x4 3x4 1.5x4 3x4 1.5x4 3x4 7-4-87-4-8 14-6-87-2-0 21-11-07-4-8 -1-2-8 1-2-8 5-7-0 5-7-0 10-11-8 5-4-8 16-4-0 5-4-8 21-11-0 5-7-0 23-1-8 1-2-8 0-6-08-8-100-6-09.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-1], [6:0-0-0,0-0-1] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.26 0.36 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.12 -0.16 0.02 (loc) 8-10 8-10 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 90 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 2=0-3-8, 6=0-3-8 Max Horz 2=-146(LC 12) Max Uplift 2=-14(LC 14), 6=-14(LC 14) Max Grav 2=946(LC 1), 6=946(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1153/47, 3-4=-1018/116, 4-5=-1018/116, 5-6=-1153/47 BOT CHORD 2-10=0/905, 8-10=0/599, 6-8=0/833 WEBS 4-8=-33/510, 5-8=-278/130, 4-10=-33/510, 3-10=-278/130 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 10-11-8, Exterior(2) 10-11-8 to 13-11-8, Interior(1) 13-11-8 to 23-1-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss E01 Truss Type Common Supported Gable Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559020 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:34 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-X2qCdtkWAyVwxrn3ENNJzbuxupr8XVpwTqR8CKyOyhd Scale = 1:66.0 1 2 3 4 5 6 7 8 9 10 19 18 17 16 15 14 13 12 11 3x4 3x4 4x4 3x4 3x4 15-11-015-11-0 -1-2-8 1-2-8 7-11-8 7-11-8 15-11-0 7-11-8 1-5-910-9-01-5-914.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-R 0.12 0.08 0.22 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 1 1 11 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 100 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 6-15 REACTIONS.All bearings 15-11-0. (lb) - Max Horz 19=226(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 16, 17, 14, 13, 12 except 19=-103(LC 12), 11=-121(LC 13), 18=-118(LC 11) Max Grav All reactions 250 lb or less at joint(s) 11, 16, 17, 18, 14, 13 except 19=279(LC 21), 15=378(LC 14), 12=264(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-6=-274/337, 6-7=-274/337 WEBS 6-15=-452/300 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) -1-2-8 to 1-11-8, Exterior(2) 1-11-8 to 7-11-8, Corner(3) 7-11-8 to 10-11-8, Exterior(2) 10-11-8 to 15-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 17, 14, 13, 12 except (jt=lb) 19=103, 11=121, 18=118. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss E02 Truss Type Common Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559021 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:36 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-TQyy2YlmhZleA9wRMoPn20_GvcT4?MeDx8wFGCyOyhb Scale: 3/16"=1' 1 2 3 4 5 6 9 8 7 10 11 12 13 14 15 16 17 4x4 3x4 4x8 4x4 4x4 3x4 3x6 3x6 7-11-87-11-8 15-11-07-11-8 -1-2-8 1-2-8 4-1-8 4-1-8 7-11-8 3-10-0 11-9-8 3-10-0 15-11-0 4-1-8 1-5-910-9-01-5-914.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.15 0.37 0.39 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.07 -0.14 0.01 (loc) 7-8 8-9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 93 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 9=0-3-8, 7=0-3-8 Max Horz 9=226(LC 13) Max Uplift 9=-18(LC 14) Max Grav 9=712(LC 21), 7=651(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-269/158, 3-4=-507/164, 4-5=-508/169, 5-6=-252/119, 2-9=-328/176 BOT CHORD 8-9=-35/415, 7-8=-7/350 WEBS 4-8=-166/502, 3-9=-482/0, 5-7=-467/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 7-11-8, Exterior(2) 7-11-8 to 10-11-8, Interior(1) 10-11-8 to 15-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss E03 Truss Type Common Qty 7 Ply 1 1GO JORDAN RES Job Reference (optional) I48559022 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:36 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-TQyy2YlmhZleA9wRMoPn20_GrcTD?MNDx8wFGCyOyhb Scale: 3/16"=1' 1 2 3 4 5 8 7 6 9 10 11 12 13 14 15 16 1.5x4 4x4 1.5x4 4x4 4x8 4x4 3x6 6x6 7-11-87-11-8 15-7-87-8-0 15-11-00-3-8 4-1-8 4-1-8 7-11-8 3-10-0 11-7-12 3-8-4 15-7-8 3-11-12 1-5-910-9-00-3-814.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.15 0.36 0.41 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.07 -0.15 0.01 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 91 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 8=0-3-8, 6=0-3-8 Max Horz 8=211(LC 13) Max Grav 8=643(LC 20), 6=647(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-252/119, 2-3=-499/170, 3-4=-494/170 BOT CHORD 7-8=-41/415, 6-7=-14/329 WEBS 3-7=-171/493, 2-8=-457/0, 4-6=-496/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 7-11-8, Exterior(2) 7-11-8 to 10-11-8, Interior(1) 10-11-8 to 15-5-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss E04 Truss Type Common Girder Qty 1 Ply 2 1GO JORDAN RES Job Reference (optional) I48559023 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:38 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-Pp3iTEn0DA?MPS4qTDSF7R3cFQAjTC_WOSPLL5yOyhZ Scale: 3/16"=1' 1 2 3 4 5 10 9 8 7 6 11 4x6 4x8 4x6 3x4 3x6 4x4 3x6 4x6 4x8 8x8 4-1-84-1-8 7-11-83-10-0 8-8-80-9-0 11-7-122-11-4 15-7-83-11-12 15-11-00-3-8 4-1-8 4-1-8 7-11-8 3-10-0 11-7-12 3-8-4 15-7-8 3-11-12 1-5-910-9-00-5-814.00 12 Plate Offsets (X,Y)-- [3:Edge,0-2-0], [5:0-2-8,0-1-8], [6:0-5-4,0-0-8], [8:0-4-0,0-4-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.16 0.30 0.66 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.09 0.01 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 232 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 10=0-3-8, 6=0-3-8 Max Horz 10=208(LC 9) Max Uplift 10=-579(LC 10), 6=-610(LC 10) Max Grav 10=3187(LC 1), 6=4315(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3271/657, 2-3=-3456/786, 3-4=-4060/929, 4-5=-4236/632, 1-10=-3115/600, 5-6=-4310/609 BOT CHORD 9-10=-201/271, 8-9=-432/2134, 7-8=-359/2696 WEBS 2-9=-535/140, 4-7=-57/459, 1-9=-371/2045, 5-7=-366/2824, 3-8=-1244/5357, 2-8=-241/360, 4-8=-477/162 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-2-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=579, 6=610. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 4794 lb down and 1669 lb up at 8-8-8, and 1634 lb down at 10-7-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Continued on page 2 October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss E04 Truss Type Common Girder Qty 1 Ply 2 1GO JORDAN RES Job Reference (optional) I48559023 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:38 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-Pp3iTEn0DA?MPS4qTDSF7R3cFQAjTC_WOSPLL5yOyhZ LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 6-10=-20 Concentrated Loads (lb) Vert: 8=-4756(F) 11=-1520(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ01 Truss Type Jack-Closed Qty 9 Ply 1 1GO JORDAN RES Job Reference (optional) I48559024 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:38 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-Pp3iTEn0DA?MPS4qTDSF7R3cqQ22THgWOSPLL5yOyhZ Scale: 3/16"=1' 1 2 3 4 5 876 9 10 11 3x4 1.5x4 1.5x4 3x6 4x4 8-7-08-7-0 -1-2-8 1-2-8 4-3-8 4-3-8 8-7-0 4-3-8 1-5-911-5-1214.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.18 0.79 0.36 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.27 -0.53 0.00 (loc) 7-8 7-8 7 l/defl >368 >184 n/a L/d 240 180 n/a PLATES MT20 Weight: 56 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-7REACTIONS. (size) 8=0-3-8, 7=Mechanical Max Horz 8=297(LC 14) Max Uplift 7=-162(LC 14) Max Grav 8=414(LC 2), 7=442(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-8=-266/249 WEBS 3-8=-408/261, 3-7=-302/257 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 8-7-0 zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 7=162. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ01A Truss Type Jack-Closed Qty 4 Ply 1 1GO JORDAN RES Job Reference (optional) I48559025 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:39 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-t?d5gaoe_U7D1cf01wzUgecnXqO4Clvfd69vtXyOyhY Scale: 3/16"=1' 1 2 3 4 765 8 910 3x4 1.5x4 1.5x4 3x6 4x4 8-7-08-7-0 4-3-8 4-3-8 8-7-0 4-3-8 1-5-911-5-1214.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.19 0.80 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.27 -0.54 0.00 (loc) 6-7 6-7 6 l/defl >364 >183 n/a L/d 240 180 n/a PLATES MT20 Weight: 54 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-6-8 oc bracing. WEBS 1 Row at midpt 3-6REACTIONS. (size) 7=0-3-8, 6=Mechanical Max Horz 7=243(LC 14) Max Uplift 6=-161(LC 14) Max Grav 7=347(LC 24), 6=449(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-7=-335/189, 2-6=-309/259 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 8-7-0 zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=161. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ01B Truss Type Jack-Closed Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559026 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:40 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-MCBTuwoHloF3fmECbeUjCr8p8EpVxBhosmuSP_yOyhX Scale = 1:61.9 1 2 3 456 10 9 87 11 12 3x4 1.5x4 1.5x4 3x6 4x4 6x6 4x8 7-3-97-3-9 8-7-01-3-7 -1-2-8 1-2-8 3-9-9 3-9-9 7-3-9 3-6-1 8-7-0 1-3-7 1-5-99-11-1214.00 12 Plate Offsets (X,Y)-- [4:0-6-8,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.71 0.41 0.32 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.19 0.00 (loc) 9-10 9-10 8 l/defl >999 >519 n/a L/d 240 180 n/a PLATES MT20 Weight: 74 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-4: 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 4-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-8, 4-8 REACTIONS. (size) 10=0-3-8, 8=Mechanical Max Horz 10=281(LC 11) Max Uplift 8=-138(LC 11) Max Grav 10=442(LC 25), 8=402(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-10=-254/242 BOT CHORD 9-10=-253/311 WEBS 3-10=-466/306, 3-9=-271/247, 4-9=-53/464, 4-8=-607/247 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 7-3-9, Exterior(2) 7-3-9 to 8-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=138. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ01C Truss Type Jack-Closed Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559027 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:41 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-qOlr5GpvW5NwGwpP8L?yl3h?SdB2ghpy4Qe0yQyOyhW Scale = 1:49.7 1 2 345 9 876 10 1.5x4 3x6 1.5x4 3x6 4x4 4x8 6-0-26-0-2 8-7-02-6-14 -1-2-8 1-2-8 6-0-2 6-0-2 8-7-0 2-6-14 1-5-98-5-1214.00 12 Plate Offsets (X,Y)-- [3:0-6-8,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.67 0.26 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.09 -0.00 (loc) 8-9 8-9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 61 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-5. BOT CHORD Rigid ceiling directly applied or 8-10-1 oc bracing. WEBS 1 Row at midpt 4-7, 3-7 REACTIONS. (size) 9=0-3-8, 7=Mechanical Max Horz 9=240(LC 11) Max Uplift 9=-4(LC 14), 7=-108(LC 11) Max Grav 9=414(LC 2), 7=372(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-9=-365/111, 2-3=-274/129 BOT CHORD 8-9=-438/407 WEBS 2-8=-216/305, 3-7=-419/239 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 6-0-2, Exterior(2) 6-0-2 to 8-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9 except (jt=lb) 7=108. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ01D Truss Type Jack-Closed Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559028 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:42 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-IaJDIcqXHPVnu4Obi3WBIGEEQ1ZoP6W5J4NZUsyOyhV Scale = 1:43.2 1 2 345 9 876 10 11 1.5x4 3x6 1.5x4 3x6 3x4 4x8 4-8-114-8-11 8-7-03-10-5 -1-2-8 1-2-8 4-8-11 4-8-11 8-7-0 3-10-5 1-5-96-11-1214.00 12 Plate Offsets (X,Y)-- [3:0-6-8,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.40 0.16 0.30 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.03 0.00 (loc) 8-9 8-9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 54 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-5. BOT CHORD Rigid ceiling directly applied or 9-8-11 oc bracing. REACTIONS. (size) 9=0-3-8, 7=Mechanical Max Horz 9=199(LC 11) Max Uplift 9=-11(LC 14), 7=-81(LC 11) Max Grav 9=414(LC 2), 7=347(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-9=-376/110, 2-3=-278/70 BOT CHORD 8-9=-367/335 WEBS 3-7=-314/190 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 4-8-11, Exterior(2) 4-8-11 to 8-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 7. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ01E Truss Type Jack-Closed Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559029 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:43 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-mntbWyr92jdeWEznGm2QqUmP6Rvq8aIFYk760IyOyhU Scale = 1:34.8 1 2 345 9 876 10 11 12 13 1.5x4 3x6 4x8 1.5x4 3x6 3x4 3-5-53-5-5 8-7-05-1-11 -1-2-8 1-2-8 3-5-5 3-5-5 8-7-0 5-1-11 1-5-95-5-1214.00 12 Plate Offsets (X,Y)-- [3:0-6-8,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.41 0.17 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.03 0.00 (loc) 7-8 7-8 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 9=0-3-8, 7=Mechanical Max Horz 9=158(LC 11) Max Uplift 9=-16(LC 14), 7=-60(LC 11) Max Grav 9=414(LC 2), 7=342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-9=-392/108, 2-3=-283/78 BOT CHORD 8-9=-295/264 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 3-5-5, Exterior(2) 3-5-5 to 7-8-3, Interior(1) 7-8-3 to 8-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 7. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ01F Truss Type Jack-Closed Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559030 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:44 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-EzQzjIrnp0mV7NY_qUZfNhJWfrDKt23OnOsgYlyOyhT Scale = 1:25.4 1 2 3 4 5 9 8 7 6 10 11 12 1.5x4 3x6 4x8 1.5x4 3x6 3x4 2-1-142-1-14 8-7-06-5-2 -1-2-8 1-2-8 2-1-14 2-1-14 8-7-0 6-5-2 1-5-93-11-1214.00 12 Plate Offsets (X,Y)-- [3:0-6-8,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.67 0.29 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.09 0.00 (loc) 7-8 7-8 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 42 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 9=0-3-8, 7=Mechanical Max Horz 9=117(LC 11) Max Uplift 9=-20(LC 14), 7=-43(LC 11) Max Grav 9=414(LC 2), 7=342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-9=-423/96, 2-3=-290/79 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 2-1-14, Exterior(2) 2-1-14 to 6-4-12, Interior(1) 6-4-12 to 8-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 7. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ01G Truss Type Jack-Closed Girder Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559031 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:45 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-i9_MxdsPaKuMlX7ANB4uvvsouFapcV_Y?2cD5ByOyhS Scale = 1:18.3 1 2 3 456 10 98 7 11 12 13 14 15 3x4 1.5x4 6x6 1.5x4 3x6 3x4 3x4 4-6-154-6-15 8-7-04-0-1 -1-2-8 1-2-8 0-10-7 0-10-7 4-6-15 3-8-9 8-7-0 4-0-1 1-5-92-5-1214.00 12 Plate Offsets (X,Y)-- [3:0-4-8,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.20 0.21 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.03 0.00 (loc) 9-10 9-10 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-6. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size) 10=0-3-8, 8=Mechanical Max Horz 10=76(LC 7) Max Uplift 10=-78(LC 10), 8=-41(LC 7) Max Grav 10=378(LC 43), 8=336(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-343/47 BOT CHORD 8-9=-65/344 WEBS 3-10=-303/85, 3-9=-21/347, 4-8=-397/61 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 8. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 65 lb down and 136 lb up at 0-10-7, 43 lb down and 27 lb up at 2-7-12, and 43 lb down and 27 lb up at 4-7-12, and 43 lb down and 27 lb up at 6-7-12 on top chord, and 20 lb down and 24 lb up at 0-10-7, 8 lb down and 7 lb up at 2-7-12, and 8 lb down and 7 lb up at 4-7-12, and 8 lb down and 7 lb up at 6-7-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-5=-60, 5-6=-60, 7-10=-20 Continued on page 2 October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ01G Truss Type Jack-Closed Girder Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559031 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:45 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-i9_MxdsPaKuMlX7ANB4uvvsouFapcV_Y?2cD5ByOyhS LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=44(F) 9=3(F) 13=3(F) 14=3(F) 15=3(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ02 Truss Type Jack-Open Qty 4 Ply 1 1GO JORDAN RES Job Reference (optional) I48559032 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:46 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-AMYk8zt1Le0DNhhMxvb7S6O_zeycLzDhEiMnddyOyhR Scale = 1:15.4 1 2 5 3 4 1.5x4 3x4 2-1-22-1-2 -1-2-8 1-2-8 2-1-2 2-1-2 0-10-142-5-122-0-42-5-129.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-R 0.11 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-1-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=79(LC 14) Max Uplift 5=-10(LC 14), 3=-19(LC 14) Max Grav 5=186(LC 1), 3=39(LC 20), 4=33(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ03 Truss Type Jack-Open Qty 9 Ply 1 1GO JORDAN RES Job Reference (optional) I48559033 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:46 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-AMYk8zt1Le0DNhhMxvb7S6OtOetbLzKhEiMnddyOyhR Scale = 1:44.4 1 2 6 5 7 8 3 4 1.5x4 3x6 3x4 2-3-82-3-8 5-4-03-0-8 -1-2-8 1-2-8 5-4-0 5-4-0 1-5-97-8-47-1-27-8-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.53 0.36 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.07 -0.10 0.06 (loc) 4-5 4-5 3 l/defl >837 >619 n/a L/d 240 180 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 6=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 6=211(LC 14) Max Uplift 3=-94(LC 14), 4=-19(LC 14) Max Grav 6=297(LC 1), 3=170(LC 20), 4=103(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. BOT CHORD 5-6=-281/226 WEBS 2-5=-262/326 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 5-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ03A Truss Type Jack-Open Qty 8 Ply 1 1GO JORDAN RES Job Reference (optional) I48559034 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:47 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-eY66MJug6x84_rGZVc6M?Kx3b2EY4QjqTM5K94yOyhQ Scale = 1:44.4 1 5 4 6 7 2 3 1.5x4 3x6 3x4 2-3-82-3-8 5-4-03-0-8 5-4-0 5-4-0 1-5-97-8-47-1-27-8-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.50 0.32 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.06 -0.09 0.05 (loc) 3-4 3-4 2 l/defl >999 >686 n/a L/d 240 180 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 5=0-3-8, 2=Mechanical, 3=Mechanical Max Horz 5=157(LC 14) Max Uplift 2=-106(LC 14), 3=-5(LC 14) Max Grav 5=205(LC 1), 2=181(LC 19), 3=103(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 1-4=-218/278 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 5-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) 2=106. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ03B Truss Type Jack-Closed Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559035 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:48 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-7kgUZfvItFGxc?rl3JdbXXUHUSdypqc_h?rtiWyOyhP Scale = 1:39.8 1 2 345 9 876 10 1.5x4 3x6 1.5x4 3x6 3x4 4x8 4-0-94-0-9 5-4-01-3-7 -1-2-8 1-2-8 4-0-9 4-0-9 5-4-0 1-3-7 1-5-96-2-414.00 12 Plate Offsets (X,Y)-- [3:0-6-8,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.30 0.11 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 8-9 8-9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 42 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-5. BOT CHORD Rigid ceiling directly applied or 9-11-5 oc bracing. REACTIONS. (size) 9=0-3-8, 7=Mechanical Max Horz 9=177(LC 11) Max Uplift 9=-9(LC 14), 7=-91(LC 11) Max Grav 9=295(LC 25), 7=242(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-9=-262/98 BOT CHORD 8-9=-353/318 WEBS 2-8=-210/273, 3-7=-329/209 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 4-0-9, Exterior(2) 4-0-9 to 5-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 7. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ03C Truss Type Jack-Closed Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559036 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:49 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-bwEsn?vwdYOoE9Qxc18q4l0Ujs_2YJj7wfaREyyOyhO Scale = 1:30.1 1 2 345 9 87 6 10 1.5x4 3x6 1.5x4 3x6 3x4 4x8 2-9-22-9-2 5-4-02-6-14 -1-2-8 1-2-8 2-9-2 2-9-2 5-4-0 2-6-14 1-5-94-8-414.00 12 Plate Offsets (X,Y)-- [3:0-6-8,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.14 0.06 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 8-9 8-9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 9=0-3-8, 7=Mechanical Max Horz 9=137(LC 11) Max Uplift 9=-17(LC 14), 7=-60(LC 11) Max Grav 9=289(LC 2), 7=214(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-9=-266/98 BOT CHORD 8-9=-279/242 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 2-9-2, Exterior(2) 2-9-2 to 5-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 7. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ03D Truss Type Jack-Closed Girder Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559037 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:50 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-37oF_LwYOsWfrI?7Akg3cyZetGJLHneH9JK_mOyOyhN Scale = 1:20.8 1 2 345 9 87 6 10 11 1.5x4 3x6 4x8 1.5x4 3x6 3x4 1-5-111-5-11 5-4-03-10-5 -1-2-8 1-2-8 1-5-11 1-5-11 5-4-0 3-10-5 1-5-93-2-414.00 12 Plate Offsets (X,Y)-- [3:0-6-8,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.24 0.12 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 -0.00 (loc) 7-8 7-8 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 9=0-3-8, 7=Mechanical Max Horz 9=96(LC 7) Max Uplift 9=-50(LC 10), 7=-51(LC 7) Max Grav 9=297(LC 2), 7=223(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-9=-297/48 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 7. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 98 lb down and 80 lb up at 1-5-11, and 60 lb down and 45 lb up at 3-4-12 on top chord, and 29 lb down and 14 lb up at 1-5-11, and 19 lb down at 3-4-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 4-5=-60, 6-9=-20 Concentrated Loads (lb) Vert: 3=-7(B) 8=2(B) 10=-7(B) 11=-7(B) October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss EJ04 Truss Type Jack-Open Qty 2 Ply 1 1GO JORDAN RES Job Reference (optional) I48559038 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:51 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-XJMdBhxA9AeWTSaKkSBI9A6riffH0ETQOz3YIryOyhM Scale = 1:19.0 1 2 5 6 3 4 3x4 3x4 3-0-83-0-8 -1-2-8 1-2-8 3-0-8 3-0-8 0-10-143-2-42-8-123-2-49.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-R 0.11 0.07 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=95(LC 14) Max Uplift 5=-2(LC 14), 3=-30(LC 14) Max Grav 5=214(LC 1), 3=70(LC 20), 4=52(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 2-11-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss F01 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559039 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:52 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-?Vv?P1yowTmN5c9WH9iXiNe0P3_Llf9acdp5rHyOyhL Scale = 1:63.0 1 2 3 4 5 6 789 10 11 12 13 14 26 25 24 23 22 21 20 19 18 17 16 15 27 28 3x4 3x4 3x4 3x4 3x4 4x4 6x6 20-1-020-1-0 -1-2-8 1-2-8 7-8-15 7-8-15 12-4-1 4-7-2 20-1-0 7-8-15 21-3-8 1-2-8 1-5-910-6-01-5-910-6-014.00 12 Plate Offsets (X,Y)-- [6:0-1-5,Edge], [9:0-2-11,Edge], [21:0-1-12,0-1-4] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-R 0.11 0.08 0.16 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 -0.00 (loc) 14 14 15 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 135 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-9. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 9-19, 8-20, 7-22, 5-23 REACTIONS.All bearings 20-1-0. (lb) - Max Horz 26=-235(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 26, 20, 24, 25, 18, 17 except 15=-110(LC 13), 16=-111(LC 10) Max Grav All reactions 250 lb or less at joint(s) 26, 19, 20, 22, 23, 24, 18, 17, 16 except 15=261(LC 20), 25=254(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-210/271, 5-6=-245/308, 9-10=-264/332 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) -1-2-8 to 1-9-8, Exterior(2) 1-9-8 to 7-8-15, Corner(3) 7-8-15 to 10-8-15, Exterior(2) 10-8-15 to 12-4-1, Corner(3) 12-4-1 to 15-4-1, Exterior(2) 15-4-1 to 21-3-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Gable requires continuous bottom chord bearing. 9) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 10) Gable studs spaced at 2-0-0 oc. 11) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 12) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 13) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 26, 20, 24, 25, 18, 17 except (jt=lb) 15=110, 16=111. 14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss F02 Truss Type Piggyback Base Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559040 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:54 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-xu1lqiz3S504KwJvPak?nojKatcdDUSs4xICvAyOyhJ Scale = 1:59.7 1 2 3 4 5 6 7 8 13 12 11 10 9 14 15 16 17 18 19 20 21 22 23 24 25 26 4x4 6x6 3x4 4x8 4x4 3x4 4x4 3x4 3x6 3x6 3x4 7-8-157-8-15 12-4-14-7-2 20-1-07-8-15 -1-2-8 1-2-8 4-0-4 4-0-4 7-8-15 3-8-12 12-4-1 4-7-2 16-0-12 3-8-12 20-1-0 4-0-4 21-3-8 1-2-8 1-5-910-6-01-5-910-6-014.00 12 Plate Offsets (X,Y)-- [5:0-3-0,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.20 0.35 0.50 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.10 -0.20 0.01 (loc) 9-10 9-10 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 127 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-12 REACTIONS. (size) 13=0-10-0, 9=0-10-0 Max Horz 13=234(LC 13) Max Uplift 13=-16(LC 14), 9=-16(LC 14) Max Grav 13=881(LC 20), 9=888(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-285/140, 3-4=-681/171, 4-5=-413/157, 5-6=-689/171, 6-7=-286/140, 2-13=-350/156, 7-9=-350/156 BOT CHORD 12-13=-26/550, 10-12=0/461, 9-10=0/463 WEBS 4-12=-52/265, 5-10=-55/315, 3-13=-633/0, 6-9=-641/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 7-8-15, Exterior(2) 7-8-15 to 11-11-14, Interior(1) 11-11-14 to 12-4-1, Exterior(2) 12-4-1 to 16-6-15, Interior(1) 16-6-15 to 21-3-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 9. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss F03 Truss Type Piggyback Base Qty 3 Ply 1 1GO JORDAN RES Job Reference (optional) I48559041 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:55 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-P4b812_hDO8xy4t5zIFEJ0GR7Hy6yyV0Ib1lRcyOyhI Scale = 1:60.4 1 2 3 4 5 6 12 11 10 9 87 13 14 15 16 17 18 19 20 21 4x4 6x8 6x8 3x4 4x8 4x4 1.5x4 3x6 3x4 3x6 1.5x4 7-8-157-8-15 12-4-14-7-2 17-4-125-0-11 19-6-82-1-12 -1-2-8 1-2-8 4-0-4 4-0-4 7-8-15 3-8-12 12-4-1 4-7-2 19-6-8 7-2-7 1-5-910-6-02-1-210-6-014.00 12 Plate Offsets (X,Y)-- [5:0-4-12,0-1-8], [6:Edge,0-1-5] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.47 0.34 0.45 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.18 0.01 (loc) 11-12 11-12 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 125 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-11, 5-8 REACTIONS. (size) 8=0-3-8, 12=0-10-0, 7=0-3-8 Max Horz 12=227(LC 13) Max Uplift 8=-49(LC 14), 12=-11(LC 14) Max Grav 8=556(LC 21), 12=829(LC 20), 7=383(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-276/139, 3-4=-622/159, 4-5=-374/149, 5-6=-328/99, 2-12=-342/156, 6-7=-403/0 BOT CHORD 11-12=-71/501, 9-11=-6/380, 8-9=-7/378 WEBS 5-8=-491/15, 3-12=-576/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 7-8-15, Exterior(2) 7-8-15 to 11-11-14, Interior(1) 11-11-14 to 12-4-1, Exterior(2) 12-4-1 to 16-6-15, Interior(1) 16-6-15 to 19-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 12. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss F04 Truss Type Piggyback Base Qty 2 Ply 1 1GO JORDAN RES Job Reference (optional) I48559042 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:56 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-uH9WFO?J_iGoaDSHW?mTsDpg0gJghNb9XFnI_2yOyhH Scale = 1:60.6 1 2 3 4 5 6 11 10 9 8 7 12 13 14 15 16 17 18 19 1.5x4 4x4 6x6 1.5x4 3x4 4x8 4x4 3x4 4x4 3x6 3x6 7-2-77-2-7 11-9-94-7-2 19-0-07-2-7 3-9-0 3-9-0 7-2-7 3-5-8 11-9-9 4-7-2 15-3-0 3-5-8 19-0-0 3-9-0 2-1-210-6-02-1-210-6-014.00 12 Plate Offsets (X,Y)-- [4:0-3-0,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.20 0.32 0.52 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.08 -0.15 0.01 (loc) 10-11 7-8 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 122 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS. (size) 11=0-3-8, 7=0-3-8 Max Horz 11=208(LC 13) Max Grav 11=781(LC 20), 7=788(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-622/176, 3-4=-376/156, 4-5=-630/175 BOT CHORD 10-11=-67/474, 8-10=0/409, 7-8=-27/391 WEBS 4-8=-63/284, 2-11=-643/30, 5-7=-651/30 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 7-2-7, Exterior(2) 7-2-7 to 11-5-6, Interior(1) 11-5-6 to 11-9-9, Exterior(2) 11-9-9 to 16-0-7, Interior(1) 16-0-7 to 18-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss G01 Truss Type Common Supported Gable Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559043 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:58 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-qfHGf40ZWJWWpXcgeQpxxeu26U2o9M5S?ZGP2xyOyhF Scale = 1:65.3 1 2 3 4 5 6 7 8 9 18 17 16 15 14 13 12 11 10 3x4 3x4 4x4 3x4 3x4 16-0-016-0-0 8-0-0 8-0-0 16-0-0 8-0-0 1-3-1210-7-121-3-1214.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-R 0.10 0.08 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 10 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 97 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-14 REACTIONS.All bearings 16-0-0. (lb) - Max Horz 18=-205(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 15, 16, 13, 12, 11 except 18=-126(LC 12), 10=-112(LC 13), 17=-101(LC 11) Max Grav All reactions 250 lb or less at joint(s) 18, 10, 15, 16, 13, 12 except 14=350(LC 14), 17=257(LC 19), 11=252(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-272/313, 5-6=-272/313 WEBS 5-14=-417/297 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) 0-1-12 to 3-1-12, Exterior(2) 3-1-12 to 8-0-0, Corner(3) 8-0-0 to 11-0-0, Exterior(2) 11-0-0 to 15-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 16, 13, 12, 11 except (jt=lb) 18=126, 10=112, 17=101. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss G02 Truss Type Roof Special Qty 7 Ply 1 1GO JORDAN RES Job Reference (optional) I48559044 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:03:59 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-IsqetQ1BHdfNRhBsC7KAUsRCZuIbupybDD?zaNyOyhE Scale = 1:67.0 1 2 3 4 5 9 87 6 10 11 12 13 14 15 4x6 4x6 4x6 1.5x4 6x8 6x8 1.5x4 1.5x4 1.5x4 4-3-104-3-10 11-8-67-4-11 16-0-04-3-10 4-3-10 4-3-10 8-0-0 3-8-6 11-8-6 3-8-6 16-0-0 4-3-10 1-3-1210-7-121-3-123-4-214.00 12 10.00 12 Plate Offsets (X,Y)-- [7:0-5-4,0-3-0], [8:0-5-4,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.18 0.43 0.22 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.15 -0.30 0.16 (loc) 7-8 7-8 6 l/defl >999 >623 n/a L/d 240 180 n/a PLATES MT20 Weight: 87 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 9=0-3-8, 6=0-3-8 Max Horz 9=-207(LC 12) Max Grav 9=628(LC 1), 6=628(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1427/45, 2-3=-1508/281, 3-4=-1305/281, 4-5=-1356/47, 1-9=-726/93, 5-6=-642/96 BOT CHORD 8-9=-261/342, 7-8=-3/438 WEBS 3-7=-195/957, 4-7=-350/259, 3-8=-209/1213, 2-8=-351/257, 1-8=0/889, 5-7=0/908 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 8-0-0, Exterior(2) 8-0-0 to 11-0-0, Interior(1) 11-0-0 to 15-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Bearing at joint(s) 9, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss G03 Truss Type Roof Special Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559045 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:00 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-m2O14m2p2xnE2rm2lrrP03zIQIhadBslStlW7pyOyhD Scale = 1:44.7 12 3 4 8 76 5 910 3x4 4x4 3x4 3x6 6x6 3x4 3x4 3x4 4-3-104-3-10 10-6-106-3-0 16-0-05-5-6 4-3-10 4-3-10 5-4-13 1-1-3 10-6-10 5-1-14 16-0-0 5-5-6 7-7-64-3-43-4-210.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.50 0.25 0.57 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.09 0.03 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 80 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-4, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 8=0-3-8, 5=Mechanical Max Horz 8=-169(LC 12) Max Uplift 8=-79(LC 10), 5=-80(LC 11) Max Grav 8=628(LC 1), 5=628(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-8=-593/122, 1-2=-546/187, 2-3=-619/82 BOT CHORD 7-8=-242/254, 6-7=-250/573, 5-6=-145/619 WEBS 1-7=-119/721, 2-7=-391/161, 3-5=-755/140 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 15-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 5. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss G04 Truss Type Roof Special Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559046 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:01 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-EEyPI63SpEv5g?LFJYMeZHWUQh0gMeHuhXU3fGyOyhC Scale = 1:53.3 123 45 9 87 6 10 11 3x4 4x6 1.5x4 3x6 6x8 1.5x4 3x4 3x4 3x4 4-3-104-3-10 11-2-66-10-11 16-0-04-9-10 4-3-10 4-3-10 6-8-4 2-4-9 11-2-6 4-6-2 16-0-0 4-9-10 9-1-65-9-43-4-210.00 12 Plate Offsets (X,Y)-- [8:0-5-4,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.42 0.26 0.55 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.11 0.02 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 95 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-5, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 1-9 REACTIONS. (size) 9=0-3-8, 6=Mechanical Max Horz 9=-207(LC 12) Max Uplift 9=-99(LC 10), 6=-100(LC 11) Max Grav 9=628(LC 1), 6=628(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-9=-593/126, 1-2=-417/177, 2-3=-417/177, 3-4=-414/55 BOT CHORD 8-9=-306/314, 7-8=-238/486, 6-7=-142/416 WEBS 1-8=-90/608, 4-7=-26/265, 4-6=-628/150 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 15-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss G05 Truss Type Roof Special Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559047 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:02 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-iRWnVR34aY1yI8wRtGtt5U3bw5N652y2vBEdBiyOyhB Scale = 1:61.6 1234 5 9 8 7 6 10 11 12 13 14 15 3x4 4x6 3x4 3x6 6x8 1.5x4 3x4 3x4 3x4 4-3-104-3-10 10-0-15-8-7 16-0-05-11-15 4-3-10 4-3-10 7-11-11 3-8-0 11-10-1 3-10-7 16-0-0 4-1-15 10-7-67-3-43-4-210.00 12 Plate Offsets (X,Y)-- [8:0-5-4,0-3-0], [9:0-1-4,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.62 0.25 0.72 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.06 0.02 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 107 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-5, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 1-9 REACTIONS. (size) 9=0-3-8, 6=Mechanical Max Horz 9=-245(LC 12) Max Uplift 9=-122(LC 10), 6=-123(LC 11) Max Grav 9=665(LC 20), 6=706(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-9=-606/133, 1-2=-383/183, 2-3=-383/183, 3-4=-395/67 BOT CHORD 8-9=-377/376, 7-8=-231/452, 6-7=-154/338 WEBS 1-8=-80/577, 2-8=-265/102, 4-7=-94/338, 4-6=-637/200 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 15-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=122, 6=123. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss H01 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559048 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:04 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-fpeXw75K59HgXS3q_hwLBv821v6iZ4qLNVjkGayOyh9 Scale = 1:63.0 1 2 3 4 5 6 7 8 9 10 11 12 21 20 19 18 17 16 15 14 13 4x4 3x4 6x6 3x4 3x6 15-11-015-11-0 -1-2-8 1-2-8 6-4-9 6-4-9 9-6-7 3-1-14 15-11-0 6-4-9 17-1-8 1-2-8 3-0-1110-6-03-0-1110-6-014.00 12 Plate Offsets (X,Y)-- [6:0-1-5,Edge], [8:0-2-11,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.14 0.05 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 -0.00 (loc) 12 12 13 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 120 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-8. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 8-16, 7-17, 5-18 REACTIONS.All bearings 15-11-0. (lb) - Max Horz 21=-244(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 18, 15, 14 except 21=-158(LC 14), 13=-126(LC 14), 19=-301(LC 13), 20=-411(LC 12) Max Grav All reactions 250 lb or less at joint(s) 21, 13, 16, 17, 18, 15, 14 except 19=492(LC 12), 20=558(LC 13) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-303/374, 5-6=-248/299, 6-7=-225/286, 7-8=-226/286, 8-9=-317/390, 9-10=-230/286 WEBS 3-20=-544/476, 3-19=-421/423 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) -1-2-8 to 1-6-7, Exterior(2) 1-6-7 to 6-4-9, Corner(3) 6-4-9 to 12-6-7, Exterior(2) 12-6-7 to 17-1-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Gable requires continuous bottom chord bearing. 9) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 10) Gable studs spaced at 2-0-0 oc. 11) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 12) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 13) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 15, 14 except (jt=lb) 21=158, 13=126, 19=301, 20=411. 14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss HR01 Truss Type Jack-Open Girder Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559049 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:10 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-Tz?pBBA5h?1pFNXzLx1lQAO0JK8bzqADlRA2TEyOyh3 Scale = 1:15.0 1 2 5 3 4 3x4 3x4 1-5-101-5-1 -2-2-13 2-2-13 1-5-10 1-5-10 1-5-92-4-110-5-11-11-102-4-117.57 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2015/TPI2014 CSI. TC BC WB Matrix-R 0.40 0.08 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 -0.01 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-5-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 4=Mechanical, 5=0-5-5 Max Horz 5=92(LC 14) Max Uplift 3=-85(LC 18), 4=-18(LC 18), 5=-46(LC 14) Max Grav 3=13(LC 10), 4=15(LC 5), 5=325(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-282/144 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4, 5. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss HR02 Truss Type Jack-Open Girder Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559050 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:10 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-Tz?pBBA5h?1pFNXzLx1lQAO0JK8CzqADlRA2TEyOyh3 Scale = 1:18.6 1 2 5 3 4 3x4 3x4 2-7-22-6-8 -2-2-13 2-2-13 2-7-2 2-7-2 1-5-93-1-30-5-12-8-23-1-37.57 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2015/TPI2014 CSI. TC BC WB Matrix-R 0.40 0.11 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 -0.02 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 5=0-5-5, 3=Mechanical, 4=Mechanical Max Horz 5=107(LC 14) Max Uplift 5=-33(LC 14), 3=-25(LC 18), 4=-2(LC 14) Max Grav 5=309(LC 1), 3=27(LC 20), 4=39(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-267/118 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) -2-2-13 to 2-0-2, Exterior(2) 2-0-2 to 2-6-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 4. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss K01 Truss Type Common Qty 3 Ply 1 1GO JORDAN RES Job Reference (optional) I48559051 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:11 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-x9ZBOWAjSJ9gtX6AvfY_zOxFGjSaiGhN_4vb0hyOyh2 Scale = 1:60.5 1 23 5467 1.5x4 4x8 1.5x4 3x4 3x4 4-3-84-3-8 3-5-3 3-5-3 4-3-8 0-10-5 8-9-411-4-210-8-69.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.14 0.16 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 58 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-5, 1-5, 3-4, 2-4REACTIONS. (size) 4=0-3-8, 5=0-3-8 Max Horz 5=44(LC 14) Max Uplift 4=-101(LC 14) Max Grav 4=232(LC 19), 5=199(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=101. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss K02 Truss Type Common Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559052 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:12 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-QM7ZbsBLDdHXUhhMSM3DVbTQ07opRjxWDkf9Y7yOyh1 Scale = 1:60.5 1 23 5467 1.5x4 4x8 1.5x4 3x4 3x4 0-3-00-3-0 4-3-84-0-8 3-5-3 3-5-3 4-3-8 0-10-5 8-9-411-4-210-8-69.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.14 0.16 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 58 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-5, 1-5, 3-4, 2-4REACTIONS. (size) 4=4-0-8, 5=4-0-8, 5=4-0-8 Max Horz 5=44(LC 14) Max Uplift 4=-101(LC 14) Max Grav 4=232(LC 19), 5=199(LC 20), 5=160(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=101. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss L01 Truss Type Half Hip Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559053 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:13 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-uYhxpCCz_wPO6rGY03aS2p0aIX9yA8hfROOi4ZyOyh0 Scale = 1:38.2 1 23 6 5 4 7 8 3x6 1.5x4 3x4 1.5x4 3x4 4x8 3-10-113-10-11 7-10-83-11-13 3-10-11 3-10-11 7-10-8 3-11-13 3-1-06-0-09.00 12 Plate Offsets (X,Y)-- [2:0-6-0,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.23 0.10 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 0.00 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 47 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-3. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 4=0-3-8, 6=0-3-8 Max Horz 6=151(LC 11) Max Uplift 4=-66(LC 11) Max Grav 4=303(LC 1), 6=303(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-273/80 WEBS 2-4=-264/144 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 3-10-11, Exterior(2) 3-10-11 to 7-8-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss L02 Truss Type Half Hip Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559054 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:14 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-MkEJ0YDclEXFk_qlan5hb0Ze6xVMvX7pg28Fc?yOyh? Scale = 1:49.8 1 2 3 6 5 4 7 8 3x6 6x6 1.5x4 3x4 1.5x4 3x4 3-11-43-11-4 7-10-83-11-4 7-0-0 7-0-0 7-10-8 0-10-8 3-1-08-4-09.00 12 Plate Offsets (X,Y)-- [2:0-4-8,0-2-4] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.67 0.09 0.45 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 55 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 2-3. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-4 REACTIONS. (size) 4=0-3-8, 6=0-3-8 Max Horz 6=214(LC 13) Max Uplift 4=-94(LC 11) Max Grav 4=335(LC 19), 6=331(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-302/70 BOT CHORD 5-6=-346/338 WEBS 2-4=-396/251, 1-5=-177/264 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 7-0-0, Exterior(2) 7-0-0 to 7-8-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss L03 Truss Type Monopitch Girder Qty 1 Ply 2 1GO JORDAN RES Job Reference (optional) I48559055 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:15 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-qxoiEuEEWYg6L8Px8Ucw7E5xcKr9e3ayvitp9SyOyh_ Scale = 1:52.6 1 2 3 6 5 478 3x6 1.5x4 4x4 3x4 3x6 3x4 3-11-43-11-4 7-10-83-11-4 3-11-4 3-11-4 7-10-8 3-11-4 3-1-08-11-149.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.18 0.12 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 120 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-4REACTIONS. (size) 4=0-3-8, 6=0-3-8 Max Horz 6=226(LC 9) Max Uplift 4=-269(LC 7), 6=-145(LC 11) Max Grav 4=1169(LC 1), 6=1263(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-764/142, 1-6=-948/123 BOT CHORD 4-5=-175/580 WEBS 2-5=-222/1015, 2-4=-1038/226, 1-5=-113/720 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=269, 6=145. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 608 lb down and 100 lb up at 1-7-12, and 608 lb down and 120 lb up at 3-7-12, and 618 lb down and 143 lb up at 5-7-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 4-6=-20 Continued on page 2 October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss L03 Truss Type Monopitch Girder Qty 1 Ply 2 1GO JORDAN RES Job Reference (optional) I48559055 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:15 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-qxoiEuEEWYg6L8Px8Ucw7E5xcKr9e3ayvitp9SyOyh_ LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 5=-608(B) 7=-608(B) 8=-608(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss M01 Truss Type Monopitch Qty 7 Ply 1 1GO JORDAN RES Job Reference (optional) I48559056 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:16 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-I7M4REEsHrozzI_7hC79gRe7JkBKNYf68MdMguyOygz Scale = 1:15.8 1 2 3 4 5 6 7 1.5x4 1.5x4 3x4 3x6 4-0-84-0-8 -1-2-8 1-2-8 4-0-8 4-0-8 0-6-142-7-26.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-4], [2:0-1-7,0-4-4] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.12 0.12 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 0.00 (loc) 2-4 2-4 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 4=Mechanical, 2=0-7-4 Max Horz 2=64(LC 13) Max Uplift 4=-4(LC 13), 2=-35(LC 16) Max Grav 4=132(LC 21), 2=255(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 3-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss N01 Truss Type Monopitch Qty 2 Ply 1 1GO JORDAN RES Job Reference (optional) I48559057 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:16 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-I7M4REEsHrozzI_7hC79gRe4gkAXNYf68MdMguyOygz Scale = 1:22.8 1 2 3 4 5 3x4 1.5x4 1.5x4 4-10-04-10-0 4-10-0 4-10-0 0-4-23-11-109.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.28 0.18 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.05 0.00 (loc) 1-3 1-3 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=Mechanical, 3=0-3-8 Max Horz 1=97(LC 13) Max Uplift 3=-18(LC 11) Max Grav 1=185(LC 1), 3=191(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-0-12 to 3-0-12, Interior(1) 3-0-12 to 4-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss N02 Truss Type Monopitch Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559058 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:17 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-mJwSfaFU19wpbSZKFvfOCfAF?8W76?vFM0MwCKyOygy Scale = 1:22.8 1 2 3 4 5 3x4 1.5x4 1.5x4 4-7-84-7-8 4-7-8 4-7-8 0-6-03-11-109.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.25 0.15 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 0.00 (loc) 1-3 1-3 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=0-3-8, 3=0-3-8 Max Horz 1=97(LC 13) Max Uplift 3=-22(LC 11) Max Grav 1=173(LC 1), 3=180(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 4-5-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB01 Truss Type Piggyback Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559059 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:18 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-EWUqswG6oT2gCc8WpdAdlsjQWYsprSYObg6TknyOygx Scale = 1:62.1 1 2 3 456789 10111213 24 23 22 21 20 19 18 17 16 15 14 25 26 27 28 29 3x4 3x4 3x4 3x4 3x4 3x4 3x4 35-1-335-1-3 3-1-5 3-1-5 35-1-3 31-11-14 0-4-102-2-60-1-100-1-109.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.20 0.12 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.01 0.00 (loc) 1 1 14 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 97 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E *Except* 8-13: 2x4 SPF No.2 PYRO-GUARD® BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-13. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 34-4-14. (lb) - Max Horz 2=55(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 14, 2, 23, 17, 16 Max Grav All reactions 250 lb or less at joint(s) 14, 2, 15 except 20=319(LC 28), 22=327(LC 1), 23=303(LC 28), 24=393(LC 1), 18=321(LC 1), 17=316(LC 28), 16=335(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-24=-279/83, 11-16=-250/62 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 7-11-12, Interior(1) 7-11-12 to 34-11-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Lumber designated with PYRO-GUARD® is a fire-retardant treatment. Lumber and plate values have been reduced for the fire-retardant treated lumber. Lumber shall be redried after treating to 19% moisture content prior to fabrication. Lumber and trusses shall be protected from weather and moisture during storage, transportation, fabrication, and erection. Adequate roof ventilation required. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 2, 23, 17, 16. 12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB02 Truss Type Piggyback Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559060 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:20 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-BucaHbHMK4IOSvIuw2C5qHom2LYIJLOh2_bapfyOygv Scale = 1:60.0 1 2 3 4 5678910 11 12 13 14 25 24 23 22 21 20 19 18 17 16 15 26 27 28 29 30 31 32 3x4 3x4 3x4 3x4 3x4 3x4 35-1-335-1-3 6-2-11 6-2-11 30-4-6 24-1-11 35-1-3 4-8-13 0-4-104-6-60-1-100-11-120-1-104-6-69.00 12 Plate Offsets (X,Y)-- [4:0-2-0,0-2-0], [12:0-2-0,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.20 0.12 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 0.00 (loc) 1 1 15 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 116 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-12. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 34-4-14. (lb) - Max Horz 2=83(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 15, 24, 25, 18, 16 Max Grav All reactions 250 lb or less at joint(s) 15, 2 except 21=401(LC 21), 23=407(LC 20), 24=400(LC 31), 25=470(LC 20), 19=401(LC 21), 18=413(LC 30), 17=353(LC 20), 16=263(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-25=-303/104 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-8-11, Interior(1) 3-8-11 to 6-2-11, Exterior(2) 6-2-11 to 11-1-1, Interior(1) 11-1-1 to 30-4-6, Exterior(2) 30-4-6 to 34-11-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 24, 25, 18, 16. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB03 Truss Type Piggyback Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559061 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:22 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-7HjLiHJdshY6hDSH2SEZviu6Z9ElnC3_WI4htYyOygt Scale = 1:60.0 1 2 3 4 56 7 89 10 11 12 13 14 25 24 23 22 21 20 19 18 17 16 15 26 27 28 29 30 31 32 33 4x6 3x4 3x4 3x4 3x4 3x4 35-1-335-1-3 9-4-0 9-4-0 27-3-1 17-11-1 35-1-3 7-10-3 0-4-106-10-60-1-100-11-120-1-106-10-69.00 12 Plate Offsets (X,Y)-- [4:0-4-8,0-2-4], [11:0-2-0,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.19 0.12 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.01 0.00 (loc) 1 1 15 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 132 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-11. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 34-4-14. (lb) - Max Horz 2=123(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 15, 25, 19, 17, 16 Max Grav All reactions 250 lb or less at joint(s) 15, 2 except 21=400(LC 20), 23=415(LC 31), 24=382(LC 20), 25=482(LC 20), 19=404(LC 21), 18=397(LC 20), 17=375(LC 21), 16=263(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 6-23=-259/76, 3-25=-308/148 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-8-11, Interior(1) 3-8-11 to 9-4-0, Exterior(2) 9-4-0 to 14-2-6, Interior(1) 14-2-6 to 27-3-1, Exterior(2) 27-3-1 to 32-1-7, Interior(1) 32-1-7 to 34-11-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 25, 19, 17, 16. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB04 Truss Type Piggyback Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559062 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:23 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-bTHjvdKFd?gzJN0TcAloSwQIOZazWfh8lypEQ_yOygs Scale = 1:61.6 1 2 3 4 5 6789 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 25 26 27 28 29 30 31 3x4 3x4 3x4 3x4 3x4 35-1-335-1-3 12-5-5 12-5-5 24-1-11 11-8-6 35-1-3 10-11-8 0-4-109-2-60-1-100-11-120-1-109-2-69.00 12 Plate Offsets (X,Y)-- [5:0-2-0,0-2-0], [9:0-2-0,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.19 0.12 0.24 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.01 0.01 (loc) 1 1 14 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 143 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-20, 6-22, 8-18 REACTIONS.All bearings 34-4-14. (lb) - Max Horz 2=163(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 14, 20, 23, 24, 16 except 15=-101(LC 14) Max Grav All reactions 250 lb or less at joint(s) 14, 2 except 20=413(LC 21), 22=400(LC 20), 23=417(LC 20), 24=477(LC 20), 18=392(LC 20), 17=410(LC 21), 16=403(LC 21), 15=260(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 7-20=-252/85, 3-24=-303/134, 11-16=-259/127 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-8-11, Interior(1) 3-8-11 to 12-5-5, Exterior(2) 12-5-5 to 17-6-10, Interior(1) 17-6-10 to 24-1-11, Exterior(2) 24-1-11 to 29-0-1, Interior(1) 29-0-1 to 34-11-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 20, 23, 24, 16 except (jt=lb) 15=101. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB05 Truss Type Piggyback Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559063 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:25 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-XsPTKJLV9cwhYhAsjboGXLWdlMFT_YgQCGILUtyOygq Scale = 1:75.7 1 2 3 4 5 6 78 9 10 11 12 13 14 1516 27 26 25 24 23 22 21 20 19 18 17 28 29 30 31 3x4 3x4 3x4 3x4 3x4 3x4 3x4 3x4 3x4 3x4 35-1-335-1-3 13-0-5 13-0-5 19-0-5 6-0-0 21-3-8 2-3-3 35-1-3 13-9-11 0-4-109-7-1011-4-00-1-100-11-120-1-109-7-109.00 12 Plate Offsets (X,Y)-- [6:0-2-0,0-2-0], [10:0-2-0,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.20 0.12 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.01 0.01 (loc) 1 1 17 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 148 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 6-9. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 8-23, 7-25, 11-21 REACTIONS.All bearings 34-4-14. (lb) - Max Horz 2=198(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 17, 23, 26, 27, 20, 19 except 18=-113(LC 14) Max Grav All reactions 250 lb or less at joint(s) 17, 2 except 23=419(LC 21), 25=446(LC 20), 26=431(LC 20), 27=475(LC 20), 21=418(LC 20), 20=459(LC 21), 19=391(LC 21), 18=297(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 8-23=-251/122, 3-27=-301/131, 12-20=-252/117 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-8-11, Interior(1) 3-8-11 to 13-0-5, Exterior(2) 13-0-5 to 16-5-10, Interior(1) 16-5-10 to 21-3-8, Exterior(2) 21-3-8 to 24-8-13, Interior(1) 24-8-13 to 34-11-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 23, 26, 27, 20, 19 except (jt=lb) 18=113. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB06 Truss Type Piggyback Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559064 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:27 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-TEXEl?NlhEAPo_KFr0qkcmbzEAxxSS9jfanRZlyOygo Scale = 1:75.0 1 2 3 4 5 6 7 8 910 11 12 13 14 15 26 25 24 23 22 21 20 19 18 17 16 27 28 29 30 31 32 3x4 3x4 3x4 3x4 3x4 3x4 3x4 3x4 3x4 35-1-335-1-3 9-11-0 9-11-0 15-11-0 6-0-0 21-3-8 5-4-8 35-1-3 13-9-11 0-4-107-3-1011-4-00-1-100-11-120-1-107-3-109.00 12 Plate Offsets (X,Y)-- [5:0-2-0,0-2-0], [9:0-2-0,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.20 0.12 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.01 0.01 (loc) 1 1 16 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 145 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 5-7. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 8-22, 10-20 REACTIONS.All bearings 34-4-14. (lb) - Max Horz 2=198(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 22, 24, 26, 19, 18 except 16=-125(LC 13), 17=-115(LC 14) Max Grav All reactions 250 lb or less at joint(s) 16, 2 except 22=428(LC 20), 24=418(LC 21), 25=430(LC 20), 26=480(LC 20), 20=406(LC 20), 19=462(LC 21), 18=389(LC 21), 17=307(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 8-22=-251/116, 3-26=-306/137, 11-19=-255/125 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-8-11, Interior(1) 3-8-11 to 9-11-0, Exterior(2) 9-11-0 to 13-6-10, Interior(1) 13-6-10 to 21-3-8, Exterior(2) 21-3-8 to 24-8-13, Interior(1) 24-8-13 to 34-11-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22, 24, 26, 19, 18 except (jt=lb) 16=125, 17=115. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB07 Truss Type Piggyback Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559065 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:28 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-yR5cyKOOSXIGP8vROjLz9z84laGSBv7tuEX?5ByOygn Scale: 3/16"=1' 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 1 17 18 19 20 21 3x4 4x4 3x4 3x4 3x4 3x4 20-5-320-5-3 6-9-11 6-9-11 20-5-3 13-7-8 0-4-104-11-1010-8-40-1-100-1-104-11-109.00 12 Plate Offsets (X,Y)-- [5:0-2-0,0-2-0], [10:Edge,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.47 0.17 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 13-14 13-14 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 86 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 5-7. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 9-10 REACTIONS.All bearings 20-5-3. (lb) - Max Horz 1=284(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 10, 2, 13, 16, 11 except 14=-106(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 10, 10, 2 except 13=337(LC 22), 14=431(LC 20), 16=274(LC 1), 12=364(LC 21), 11=481(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-500/495, 2-3=-430/432, 3-4=-363/365, 7-8=-252/267 WEBS 4-14=-358/268, 8-11=-285/151 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-3-7, Interior(1) 3-3-7 to 6-9-11, Exterior(2) 6-9-11 to 11-0-9, Interior(1) 11-0-9 to 20-3-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Provide adequate drainage to prevent water ponding. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10, 2, 13, 16, 11 except (jt=lb) 14=106. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB08 Truss Type Piggyback Qty 3 Ply 1 1GO JORDAN RES Job Reference (optional) I48559066 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:29 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-Qde_AgO0DrQ71IUdyRsCiBgFC_cYwMN07uGYdeyOygm Scale = 1:59.2 1 2 3 4 5 6 7 11 10 9 8 3x4 3x4 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 14-5-314-5-3 14-5-3 14-5-3 0-4-1010-8-40-1-100-1-109.00 12 Plate Offsets (X,Y)-- [7:0-0-12,0-1-8], [8:Edge,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.49 0.18 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 -0.00 (loc) 1 1 8 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 64 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-8 REACTIONS.All bearings 13-8-14. (lb) - Max Horz 2=283(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 8, 2, 10, 11, 9 Max Grav All reactions 250 lb or less at joint(s) 8, 2 except 10=392(LC 20), 11=286(LC 1), 9=430(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-424/433, 3-5=-343/351, 5-6=-253/260 WEBS 5-10=-250/121, 6-9=-262/151 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-2-10, Interior(1) 3-2-10 to 14-3-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 2, 10, 11, 9. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB09 Truss Type Piggyback Qty 4 Ply 1 1GO JORDAN RES Job Reference (optional) I48559067 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:30 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-upCMN0Pe_9YzfS3pW8NREODQINyTfrPAMY06A4yOygl Scale = 1:70.1 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 17 18 3x4 3x4 3x4 3x4 3x4 3x4 18-5-318-5-3 15-3-8 15-3-8 18-5-3 3-1-11 0-4-1011-4-00-1-108-11-120-1-109.00 12 Plate Offsets (X,Y)-- [7:0-2-0,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.47 0.13 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 -0.00 (loc) 1 1 10 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 88 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-12, 8-11 REACTIONS.All bearings 17-8-14. (lb) - Max Horz 2=278(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 13, 15, 12, 11 except 10=-127(LC 14) Max Grav All reactions 250 lb or less at joint(s) 10, 2 except 13=416(LC 20), 15=437(LC 20), 12=475(LC 20), 11=359(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-312/343, 8-9=-236/277, 9-10=-255/297 WEBS 3-15=-284/118, 6-12=-268/130, 8-11=-290/169 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-3-7, Interior(1) 3-3-7 to 15-3-8, Exterior(2) 15-3-8 to 18-3-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 15, 12, 11 except (jt=lb) 10=127. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB10 Truss Type Piggyback Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559068 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:31 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-M0mlbMQGkShqGce04rvgncmcLnIpOIgJaClfiWyOygk Scale = 1:64.9 1 2 3 4 5 6 78 9 10 16 15 14 13 12 11 17 18 19 3x4 3x4 3x4 3x4 3x4 3x4 3x4 18-5-318-5-3 14-4-11 14-4-11 16-2-6 1-9-11 18-5-3 2-2-13 0-4-1010-7-140-1-108-11-120-1-1010-7-149.00 12 Plate Offsets (X,Y)-- [7:0-2-0,0-2-0], [8:0-2-0,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.45 0.13 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 -0.00 (loc) 1 1 11 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 88 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-13, 9-12 REACTIONS.All bearings 17-8-14. (lb) - Max Horz 2=268(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 14, 16, 13, 12 except 11=-108(LC 14) Max Grav All reactions 250 lb or less at joint(s) 11, 2 except 14=420(LC 20), 16=436(LC 20), 13=469(LC 20), 12=352(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-322/344, 9-10=-226/256, 10-11=-238/261 WEBS 3-16=-283/116, 6-13=-262/142, 9-12=-255/166 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-3-7, Interior(1) 3-3-7 to 14-4-11, Exterior(2) 14-4-11 to 18-3-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 16, 13, 12 except (jt=lb) 11=108. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB11 Truss Type Piggyback Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559069 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:32 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-qCK7oiRuVmphulCCdZQvJpIptBeH7j2SpsVCEzyOygj Scale = 1:50.8 1 2 3 4 5 678 14 13 12 11 10 9 15 16 17 18 19 3x4 3x4 3x4 3x4 3x4 18-5-318-5-3 11-3-5 11-3-5 18-5-3 7-1-14 0-4-108-3-140-1-100-1-109.00 12 Plate Offsets (X,Y)-- [5:0-2-0,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.27 0.11 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 -0.00 (loc) 1 1 9 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 82 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-8. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 17-8-14. (lb) - Max Horz 2=222(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 9, 12, 14, 11, 10 Max Grav All reactions 250 lb or less at joint(s) 9, 2 except 12=426(LC 20), 14=433(LC 20), 11=438(LC 22), 10=337(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-303/314 WEBS 3-14=-282/132, 6-11=-257/103 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-3-7, Interior(1) 3-3-7 to 11-3-5, Exterior(2) 11-3-5 to 15-6-4, Interior(1) 15-6-4 to 18-3-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 12, 14, 11, 10. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB12 Truss Type Piggyback Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559070 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:33 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-IOuV02RWG4xYWvnOBGx8s1r?9b_WsCYc2WEmmPyOygi Scale = 1:38.1 1 2 3 4 5678 14 13 12 11 10 9 15 16 17 18 19 20 3x4 3x4 3x4 18-5-318-5-3 8-2-0 8-2-0 18-5-3 10-3-3 0-4-105-11-140-1-100-1-109.00 12 Plate Offsets (X,Y)-- [4:0-2-0,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.17 0.11 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 -0.00 (loc) 1 1 9 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 72 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-8. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 17-8-14. (lb) - Max Horz 2=159(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 9, 12, 14, 11, 10 Max Grav All reactions 250 lb or less at joint(s) 2 except 12=406(LC 20), 14=437(LC 20), 11=424(LC 21), 10=323(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-14=-283/149, 6-11=-258/76 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-3-7, Interior(1) 3-3-7 to 8-2-0, Exterior(2) 8-2-0 to 12-4-15, Interior(1) 12-4-15 to 18-3-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 12, 14, 11, 10. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB13 Truss Type Piggyback Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559071 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:35 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-En0FQkTnohBGlDxnJhzcxSwLnOg1K8QvVpjtrHyOygg Scale = 1:46.8 1 2 34567891011 12 20 19 18 17 16 15 14 13 21 22 23 4x4 3x4 3x4 3x4 3x4 26-6-326-6-3 5-0-11 5-0-11 25-6-6 20-5-11 26-6-3 0-11-13 0-4-103-7-140-1-102-11-00-1-103-7-149.00 12 Plate Offsets (X,Y)-- [3:0-2-8,0-2-4], [11:0-2-0,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.16 0.11 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 -0.00 (loc) 1 1 13 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 85 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 3-11. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 25-9-14. (lb) - Max Horz 2=87(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 13, 2, 19, 16, 15, 14 Max Grav All reactions 250 lb or less at joint(s) 13, 2 except 17=324(LC 28), 19=327(LC 29), 20=384(LC 28), 16=317(LC 29), 15=334(LC 28), 14=268(LC 29) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-19=-253/79, 4-20=-271/102, 9-15=-251/70 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=26ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-3-7, Interior(1) 3-3-7 to 5-0-11, Exterior(2) 5-0-11 to 9-3-2, Interior(1) 9-3-2 to 25-6-6, Exterior(2) 25-6-6 to 26-4-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 2, 19, 16, 15, 14. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB14 Truss Type GABLE Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559072 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:36 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-jzaee4UPZ?J7NNWzsPUrUfTYSo1d3bA2kTTQNkyOygf Scale = 1:34.7 2 3 4 5 6 10 9 8 1 11 12 13 14 7 4x4 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 8-9-148-9-14 4-4-15 4-4-15 8-9-14 4-4-15 -0-0-45-1-85-1-120-1-20-1-1014.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.04 0.02 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-9-14. (lb) - Max Horz 1=94(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 7, 2, 10, 8 except 1=-108(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 7, 2, 6, 9, 10, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-2-10 to 3-2-10, Interior(1) 3-2-10 to 4-4-15, Exterior(2) 4-4-15 to 7-4-15, Interior(1) 7-4-15 to 8-7-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 1, 7, 2, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 2, 10, 8 except (jt=lb) 1=108. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB15 Truss Type Piggyback Qty 11 Ply 1 1GO JORDAN RES Job Reference (optional) I48559073 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:37 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-B970rPV1KIR__X5AQ6040t?gZCLbo24Bz7CzvAyOyge Scale = 1:33.9 1 2 3 4 5 6 7 8 9 10 4x4 3x4 3x4 1.5x4 8-9-148-9-14 4-4-15 4-4-15 8-9-14 4-4-15 0-5-105-0-20-1-100-5-100-1-1014.00 12 Plate Offsets (X,Y)-- [2:0-2-10,0-1-8], [4:0-2-10,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.21 0.10 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.01 0.01 0.00 (loc) 5 5 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 2=7-9-7, 4=7-9-7, 6=7-9-7 Max Horz 2=94(LC 13) Max Uplift 2=-22(LC 14), 4=-22(LC 14) Max Grav 2=215(LC 1), 4=215(LC 1), 6=239(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-2-10 to 3-2-10, Interior(1) 3-2-10 to 4-4-15, Exterior(2) 4-4-15 to 7-4-15, Interior(1) 7-4-15 to 8-7-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB16 Truss Type Piggyback Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559074 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:38 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-fMhO3lVf5cZrchgM_qXJZ4YuLciJXV1LBnyXScyOygd Scale = 1:11.4 12 3 4 5 6 4x4 3x4 3x4 1.5x4 3-1-143-1-14 1-6-15 1-6-15 3-1-14 1-6-15 0-5-101-8-80-1-100-5-100-1-1014.00 12 Plate Offsets (X,Y)-- [2:0-2-10,0-1-8], [4:0-2-10,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.01 0.01 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 4 4 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 2=2-1-7, 4=2-1-7, 6=2-1-7 Max Horz 2=31(LC 13) Max Uplift 2=-8(LC 14), 4=-8(LC 14) Max Grav 2=73(LC 1), 4=73(LC 1), 6=64(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB17 Truss Type Piggyback Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559075 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:39 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-7YFmG5WHswhiEqFYYX2Y5I53h02KGyDUQRh4_3yOygc Scale = 1:15.5 1 2 3 4 5 6 4x4 3x4 3x4 1.5x4 4-7-24-7-2 2-3-9 2-3-9 4-7-2 2-3-9 0-5-102-6-80-1-100-5-100-1-1014.00 12 Plate Offsets (X,Y)-- [2:0-2-10,0-1-8], [4:0-2-10,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.04 0.02 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 4 5 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 2=3-6-11, 4=3-6-11, 6=3-6-11 Max Horz 2=-47(LC 12) Max Uplift 2=-12(LC 14), 4=-12(LC 14) Max Grav 2=109(LC 1), 4=109(LC 1), 6=108(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss PB18 Truss Type Piggyback Qty 6 Ply 1 1GO JORDAN RES Job Reference (optional) I48559076 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:40 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-bkp8URXvdDpZr_qk5EZneVdERPOZ?OTef5RdWVyOygb Scale = 1:15.5 1 2 3 4 5 6 4x4 3x4 3x4 1.5x4 4-7-24-7-2 2-3-9 2-3-9 4-7-2 2-3-9 0-5-102-6-80-1-100-5-100-1-1014.00 12 Plate Offsets (X,Y)-- [2:0-2-10,0-1-8], [4:0-2-10,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.04 0.02 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 4 5 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 2=3-6-11, 4=3-6-11, 6=3-6-11 Max Horz 2=-47(LC 12) Max Uplift 2=-12(LC 14), 4=-12(LC 14) Max Grav 2=109(LC 1), 4=109(LC 1), 6=108(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss R01 Truss Type Flat Supported Gable Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559077 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:40 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-bkp8URXvdDpZr_qk5EZneVd54POB?Btef5RdWVyOygb Scale = 1:41.812 3 65 4 78 3x6 3x4 1.5x4 1.5x4 6x6 1.5x4 4-4-04-4-0 4-4-0 4-4-0 7-8-4LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.64 0.05 0.88 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 42 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD 2-0-0 oc purlins: 1-3, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 1-6 REACTIONS. (size) 6=4-4-0, 4=4-4-0, 5=4-4-0 Max Horz 6=-188(LC 10) Max Uplift 6=-374(LC 10), 4=-9(LC 11), 5=-379(LC 11) Max Grav 6=397(LC 13), 4=70(LC 1), 5=468(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-868/889 BOT CHORD 5-6=-320/356 WEBS 1-5=-883/883 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) 0-1-12 to 3-1-12, Exterior(2) 3-1-12 to 4-2-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 6=374, 5=379. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V01 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559078 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:42 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-X7xvu7YA9r3G5Iz7DfbFjwjYCD3ATHsx6PwkbOyOygZ Scale = 1:35.0 1 2 3 4 5 876 9 10 3x4 4x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 14-8-314-8-3 14-8-80-0-5 7-4-4 7-4-4 14-8-8 7-4-4 0-0-45-6-30-0-49.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.15 0.08 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 47 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-7-13. (lb) - Max Horz 1=83(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=250(LC 1), 8=328(LC 27), 6=328(LC 28) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-4 to 3-4-4, Interior(1) 3-4-4 to 7-4-4, Exterior(2) 7-4-4 to 10-4-4, Interior(1) 10-4-4 to 14-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V02 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559079 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:43 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-?JVH6TZow8B7iSYJnN6UG8FiedOgClr4L3fI7qyOygY Scale = 1:21.7 1 2 3 4 5 6 7 8 3x4 4x4 3x4 1.5x4 0-0-50-0-5 8-5-138-5-8 4-2-15 4-2-15 8-5-13 4-2-15 0-0-43-2-30-0-49.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.23 0.12 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=8-5-3, 3=8-5-3, 4=8-5-3 Max Horz 1=-46(LC 12) Max Uplift 1=-14(LC 14), 3=-14(LC 14) Max Grav 1=168(LC 1), 3=168(LC 1), 4=273(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-4 to 3-5-4, Interior(1) 3-5-4 to 4-2-15, Exterior(2) 4-2-15 to 7-2-15, Interior(1) 7-2-15 to 8-0-9 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V03 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559080 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:44 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-UW3fJpaQhSJ_Kc7WK4ejoLos_1iFxB3DajPrfGyOygX Scale = 1:40.9 1 2 3 4 5 6 10 9 8 7 11 12 3x4 4x4 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 11-5-011-5-0 -1-2-8 1-2-8 8-5-15 8-5-15 11-5-0 2-11-1 1-10-64-8-66-10-114.00 12 9.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-R 0.26 0.23 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 2 2 7 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-5-0. (lb) - Max Horz 10=178(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 10, 7, 8, 9 Max Grav All reactions 250 lb or less at joint(s) 10, 7 except 8=426(LC 5), 9=316(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-8=-328/78 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 11-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 7, 8, 9. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V04 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559081 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:45 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-yic1X8b2RmRryliiuo9yLZL1EQ3Mgf3NoN8OBiyOygW Scale = 1:27.4 1 2 3 4 65 7 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 10-0-310-0-3 7-1-2 7-1-2 10-0-3 2-11-1 0-0-42-4-64-6-114.00 12 9.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.29 0.17 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=9-11-7, 5=9-11-7, 6=9-11-7 Max Horz 1=113(LC 13) Max Uplift 5=-16(LC 13), 6=-14(LC 16) Max Grav 1=168(LC 20), 5=111(LC 27), 6=488(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-6=-367/112 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-11-5 to 3-11-5, Interior(1) 3-11-5 to 9-10-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V05 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559082 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:46 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-QuAQkUcgC3ZiZvHuSVgBumtFNqRZP64W11uyk9yOygV Scale = 1:13.6 1 2 3 3x4 1.5x4 1.5x4 2-10-1 2-10-1 0-0-42-1-99.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.08 0.05 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=2-9-12, 3=2-9-12 Max Horz 1=46(LC 11) Max Uplift 3=-8(LC 11) Max Grav 1=90(LC 1), 3=93(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V06 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559083 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:46 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-QuAQkUcgC3ZiZvHuSVgBumtDzqP9P6JW11uyk9yOygV Scale = 1:38.5 1 2 3 54 6 7 83x4 1.5x4 1.5x4 1.5x4 1.5x4 8-2-8 8-2-8 0-0-46-1-149.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.23 0.14 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 30 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=8-2-2, 4=8-2-2, 5=8-2-2 Max Horz 1=156(LC 13) Max Uplift 4=-26(LC 11), 5=-53(LC 14) Max Grav 1=137(LC 20), 4=171(LC 19), 5=415(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-286/164 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-4 to 3-5-4, Interior(1) 3-5-4 to 8-0-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V07 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559084 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:47 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-u5koyqcIzNiZB3s50CBQQ_QM0EkG8ZKgGhdVGbyOygU Scale: 1/2"=1' 1 2 3 4 3x4 1.5x4 1.5x4 5-1-2 5-1-2 0-0-43-9-149.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.34 0.21 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=5-0-13, 3=5-0-13 Max Horz 1=92(LC 11) Max Uplift 3=-16(LC 11) Max Grav 1=180(LC 1), 3=185(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-4 to 3-5-4, Interior(1) 3-5-4 to 4-11-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V08 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559085 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:48 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-MHIA9AdwkhqQpDRHZwifzBzWHe5KtzGpULN3o1yOygT Scale = 1:56.3 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 1.5x4 3x4 3x4 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 3x4 1.5x4 14-2-814-2-8 -1-2-8 1-2-8 8-5-15 8-5-15 14-2-8 5-8-9 2-11-45-9-310-0-104.00 12 9.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.43 0.16 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 1 1 8 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 69 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 11-12. WEBS 1 Row at midpt 7-8 REACTIONS.All bearings 14-2-8. (lb) - Max Horz 12=263(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 12, 8, 9, 10 except 11=-230(LC 13) Max Grav All reactions 250 lb or less at joint(s) 8 except 12=305(LC 13), 9=455(LC 24), 10=470(LC 5), 11=333(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-12=-453/338, 2-3=-267/238 BOT CHORD 11-12=-377/345 WEBS 6-9=-270/88, 4-10=-334/80, 2-11=-413/487 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 14-0-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 8, 9, 10 except (jt=lb) 11=230. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V09 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559086 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:49 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-qTsYMWeZV_yHQN0T7dDuVPVjs2SDcSOyj?6cLUyOygS Scale = 1:45.7 1 2 3 4 5 6 7 11 10 9 8 12 13 14 3x4 3x4 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 -0-9-140-9-14 14-2-814-2-8 -1-2-8 1-2-8 8-5-15 8-5-15 14-2-8 5-8-9 0-3-153-5-37-8-104.00 12 9.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.25 0.11 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 -0.00 (loc) 1 1 8 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 53 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-0-6. (lb) - Max Horz 2=200(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 8, 9, 11 Max Grav All reactions 250 lb or less at joint(s) 8, 2 except 9=399(LC 24), 10=408(LC 21), 11=331(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-254/222 WEBS 6-9=-270/86, 4-10=-329/64 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 14-0-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 9, 11. 9) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V10 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559087 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:50 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-IgQwasfBGI482XbfhLk72c2uaRnFLwP6yfs9twyOygR Scale = 1:33.3 1 2 3 4 65 7 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 9-0-39-0-3 3-3-10 3-3-10 9-0-3 5-8-9 0-0-41-1-35-4-104.00 12 9.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.25 0.13 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=8-11-7, 5=8-11-7, 6=8-11-7 Max Horz 1=135(LC 13) Max Uplift 5=-30(LC 13), 6=-27(LC 16) Max Grav 1=143(LC 20), 5=126(LC 23), 6=408(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-300/119 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-11-5 to 3-3-10, Interior(1) 3-3-10 to 8-10-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V11 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559088 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:51 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-ms_JnCfp1cC?gg9sF2GMbqb4or7w4NpFBJbjPMyOygQ Scale = 1:31.4 1 2 3 54 6 7 3x4 1.5x4 1.5x4 1.5x4 1.5x4 6-8-9 6-8-9 0-0-45-0-79.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.16 0.10 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=6-8-4, 4=6-8-4, 5=6-8-4 Max Horz 1=126(LC 13) Max Uplift 1=-11(LC 12), 4=-21(LC 11), 5=-45(LC 14) Max Grav 1=77(LC 24), 4=132(LC 19), 5=324(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-4 to 3-5-4, Interior(1) 3-5-4 to 6-6-13 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V12 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559089 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:52 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-F2Xh?YgRovKsIqk2omnb717FqFTKpqZPPzLGxoyOygP Scale = 1:16.4 1 2 3 3x4 1.5x4 1.5x4 3-7-4 3-7-4 0-0-42-8-79.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.14 0.09 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=3-6-15, 3=3-6-15 Max Horz 1=62(LC 13) Max Uplift 3=-11(LC 11) Max Grav 1=121(LC 1), 3=124(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V13 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559090 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:53 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-jE53Cuh3ZDSjv_JEMTIqgFgQxfoTYFYYed4pUFyOygO Scale = 1:44.8 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 3x4 4x4 3x4 6x6 19-10-319-10-3 19-10-80-0-5 9-11-4 9-11-4 19-10-8 9-11-4 0-0-47-5-70-0-49.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.18 0.16 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 68 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 19-9-13. (lb) - Max Horz 1=-114(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 11, 12, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=367(LC 19), 11=406(LC 19), 12=261(LC 1), 9=406(LC 20), 8=260(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-268/120, 5-9=-268/120 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-4 to 3-5-4, Interior(1) 3-5-4 to 9-11-4, Exterior(2) 9-11-4 to 12-11-4, Interior(1) 12-11-4 to 19-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 11, 12, 9, 8. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V14 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559091 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:54 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-BRfRQDihKXaZX8uRwBp3CSDbE39wHj_itHqN0hyOygN Scale: 3/8"=1' 1 2 3 4 5 876 9 10 11 12 3x4 4x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 0-0-50-0-5 13-7-1313-7-8 6-9-15 6-9-15 13-7-13 6-9-15 0-0-45-1-70-0-49.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.15 0.08 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 42 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 13-7-3. (lb) - Max Horz 1=-77(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=256(LC 1), 8=309(LC 27), 6=309(LC 28) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-4 to 3-5-4, Interior(1) 3-5-4 to 6-9-15, Exterior(2) 6-9-15 to 9-9-15, Interior(1) 9-9-15 to 13-2-9 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V15 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559092 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:55 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-fdDpdZiJ5qiQ9ITdUuKIlglmdSVz0Byr5xZwY7yOygM Scale = 1:19.3 1 2 3 4 3x4 4x4 3x4 1.5x4 7-4-137-4-13 7-5-30-0-5 3-8-9 3-8-9 7-5-3 3-8-9 0-0-42-9-70-0-49.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.17 0.09 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=7-4-8, 3=7-4-8, 4=7-4-8 Max Horz 1=39(LC 13) Max Uplift 1=-12(LC 14), 3=-12(LC 14) Max Grav 1=145(LC 1), 3=145(LC 1), 4=235(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V16 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559093 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:56 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-7pnBqvjys8qHmS2p1brXItIwBsqvlb9_KbJU4ayOygL Scale = 1:50.6 1 2 3 4 765 8 9 103x4 4x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 8-4-158-4-15 6-8-15 6-8-15 8-4-15 1-8-0 0-0-47-10-65-11-114.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.25 0.11 0.22 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 42 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-4-11. (lb) - Max Horz 1=191(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6 except 7=-129(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=344(LC 19), 7=415(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-330/327 WEBS 2-7=-352/267 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 6-8-15, Exterior(2) 6-8-15 to 8-3-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6 except (jt=lb) 7=129. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V17 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559094 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:56 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-7pnBqvjys8qHmS2p1brXItIwUsqQldj_KbJU4ayOygL Scale = 1:41.4 1 2 3 4 765 8 9 3x4 4x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 7-1-87-1-8 5-5-8 5-5-8 7-1-8 1-8-0 0-0-46-4-64-5-114.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.23 0.08 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 7-1-4. (lb) - Max Horz 1=150(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 5, 6 except 1=-159(LC 12), 7=-135(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=255(LC 19), 7=380(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-320/318 WEBS 2-7=-370/298 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 5-5-8, Exterior(2) 5-5-8 to 6-11-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6 except (jt=lb) 1=159, 7=135. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V18 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559095 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:57 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-b0La2FkadSy8Obd0bJMmq5q4ZGAKU4k8ZF21d0yOygK Scale = 1:33.0 1 2 3 54 6 7 3x4 4x4 1.5x4 1.5x4 1.5x4 5-10-15-10-1 4-2-1 4-2-1 5-10-1 1-8-0 0-0-44-10-62-11-114.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.27 0.10 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-10-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=5-9-13, 4=5-9-13, 5=5-9-13 Max Horz 1=109(LC 13) Max Uplift 1=-17(LC 14), 4=-62(LC 14), 5=-19(LC 11) Max Grav 1=173(LC 20), 4=74(LC 20), 5=281(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 4-2-1, Exterior(2) 4-2-1 to 5-8-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V19 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559096 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:58 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-3CvyFblCOl4?0lCC90u?NINGJgVyDY2Houoa9SyOygJ Scale = 1:25.0 1 2 3 4 5 3x4 3x4 3x4 1.5x4 4-6-104-6-10 3-9-5 3-9-5 4-6-10 0-9-5 0-0-44-4-1414.00 12 Plate Offsets (X,Y)-- [2:0-1-5,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-R 0.21 0.14 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-10 oc purlins, except end verticals, and 2-0-0 oc purlins: 2-3. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=4-6-7, 4=4-6-7 Max Horz 1=112(LC 11) Max Uplift 4=-48(LC 11) Max Grav 1=174(LC 20), 4=183(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 3-9-5, Exterior(2) 3-9-5 to 4-4-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 28,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 26663A Truss V20 Truss Type Valley Qty 1 Ply 1 1GO JORDAN RES Job Reference (optional) I48559097 8.520 s Aug 27 2021 MiTek Industries, Inc. Thu Oct 28 07:04:59 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:CHIb_pJg75tmoj676vhBAryOzIA-XOTKTxmq83CsdvnOjkPEvWwSv4sAy_IR0YX8huyOygI Scale = 1:22.2 1 2 33x4 1.5x4 1.5x4 3-3-3 3-3-3 0-0-43-9-1214.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.15 0.07 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=3-3-0, 3=3-3-0 Max Horz 1=89(LC 11) Max Uplift 3=-41(LC 11) Max Grav 1=129(LC 20), 3=135(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. October 28,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87 654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System General Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths