HomeMy WebLinkAboutWINDWARD AT LEGACY 1302 - WL1302(AS DESIGNED)[289600]2Indiana 2020 Performance Compliance
Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V
Community: WINDWARD AT LEGAC
WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED)
Organization TSI Energy Solutions
Devin Sielschott
Builder LENNAR HOMES
Inspection Status Results are projected
This report is based on a proposed design and does not confirm field enforcement of design elements.
Annual Energy Cost
Design Heating
Cooling Water Heating Mechanical Ventilation
Indiana 2020 Performance
$467
$87 $350 $30 $934 $512 $0 $1,446
As Designed
$458 $105 $350
SubTotal -Used to determine compliance Lights & Appliances w/out Ventilation Onsite generation Total
Requirements
1105
1102.4.1.2
1102.5
1102.5
1104.1
Performance-based compliance passes by 1.1 %
Air Leakage Testing
Area-weighted average fenestration SHGC
Area-weighted average fenestration U-Factor
Lighting Equipment Efficiency
Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met.
1103.6
1103.6.1
Mechanical Ventilation Rate
Mechanical Ventilation Efficacy
Air sealing is 5.00 ACH at 50 Pa. It must not exceed 5.00 ACH at 50 Pa.
Design exceeds requirements for Indiana 2020 Performance compliance by 1.1 %.
$10 $924 $512 $0 $1,435
As a 3rd party extension of the code jurisdiction utilizing these reports. I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions Digitally signed: 9/9/21 at 3:15 PM
Ekotrope RATER -Version 3.2.4.2740
Indiana 2020 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm, including appropriate amendments. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report.
7107 EQUALITY BLVD
CARMEL, IN 46032 Builder: LENNAR HOMES
Model: LOCKERBIE V Community: WINDWARD AT LEGACY 1302 This report is based on a proposed design and does not confirm field enforcement of design elements.
THIS HOME IS CERTIFIED TO MEET THE IN DIANA 2020
ENERGY CODE
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls N/A
Framed Floor R-38
Building Features
Duct Supply R-25.0, Return R-25.0
Duct Leakage to Outside 5 CFM25 I 100 ft2
Slab R-10.0 Perimeter, R-0.0Under
Total Duct Leakage 8 CFM25 / 100 ft2 (Post-Construction)
Heating Furnace• Natural Gas• 96.2 AFUE
Cooling Air Conditioner• Electric• 13 SEER
Infiltration 5 ACH50 Water Heating Residential Water Heater• Electric • 0.93 EnergyFactor Window U-Value: 0.33, SHGC: 0.31
As a 3rel party extension of tile code juriseliction utilizing these reports, I certify that this energy coele compliance Clocument has been created in accorelance with the requirements of Chapter 4 of the aelopted International Energy Conservation Coele based on Climate Zone 5. If rating is Projecteel, I certify that the building Clesign Clescribeel herein is consistent with the building plans, specifications, anel other calculations subnitteel with the permit application. If rating is Confirmeel, I certify that the aelelress referenceel above has been inspected/tested anel that the mandatory provisions of the IECC have been ins:alled to meet or exceeel the intent of the IECC or will be verifieel as such by another party. /:,�_,u,<�-
Name:
Organization:
oevin Sielschott Signature: ot::>-= v'-".,,. __ _
TSI Energy Solutions Digitally signed: 9/9/21 at 3: 15 PM
Ekotrope RAI ER - Version 3.2.4.2740
Indiana 2020 Certificate compliance results calculated using Ekotrope RATER's energy and code compliance algorithm, including appropriate amendments. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report.
Energy Code Inspection Checklist
Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V
Community: WINDWARD AT LEGAC
WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED)
General Building Information
Conditioned Area (sq ft) Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Organization TSI Energy Solutions
Devin Sielschott
Builder LENNAR HOMES
1,834 16,012 4,328
Inspection Status Results are projected
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
□Name: MAIN(374 s.f., 40 ft. exterior perimeter)R-10 perimeter insulation, R-0 under slab insulation.
Framed Floor
□Name: OVER GARAGE (386 s.f.)R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
None Present
Above Grade Wall
□
□
□
Name: COND/AMB (670 s.f.) R-3 continuous insulation, R-13 cavity insulationInsulation Grade: I
Name: COND/AMB 2X6 (170 s.f.)
R-3 continuous insulation, R-19 cavity insulationInsulation Grade: I
Name: COND/GAR 2X6 (160 s.f.) R-0 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property
7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V
Community: WINDWARD AT LEGAC
WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED)
Name: COND/COND (1,592 s.f.)
Organization TSI Energy Solutions
Devin Sielschott
Builder LENNAR HOMES
□ R-0 continuous insulation, R-22 cavity insulationInsulation Grade: I
Rim Joist
□
□
Name: COND/AMB (72 s.f.)R: 13.575
Name: COND/COND (144 s.f.) R: 10.876
Ceiling/ Roof
□Name: SECOND (760 s.f.)R-27.85 continuous insulation, R-10.15 cavity insulationInsulation Grade: I
Opaque Door
□
□
Name: FRONT (20 s.f.)U: 0.182
Name: GARAGE (18 s.f.) U: 0.182
Glazing
Inspection Status Results are projected
D Name: FRONT (45 s.f.), U: 0.330, SHGC: 0.31, Orientation: WEST
D Name: FRONT 2X6 (78 s.f.), U: 0.330, SHGC: 0.31, Orientation: WEST
D Name: BACK (70 s.f.), U: 0.330, SHGC: 0.31, Orientation: EAST
D Name: SLIDER (33 s.f.), U: 0.330, SHGC: 0.31, Orientation: EAST
Skylight
None Present
2
Energy Code Inspection Checklist
Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V
Community: WINDWARD AT LEGAC
WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED)
Mechanical Ventilation
Organization TSI Energy Solutions
Devin Sielschott
Builder LENNAR HOMES
Inspection Status Results are projected
□Mechanical ventilation system rated for, and capable of, providing continuous ventilation.System shall include automatic timing controls.
System type: Exhaust Only, 24 hrs/day, 12 Watts
Mechanical Equipment
D FURNACE • Natural Gas • 100% Heating Load @ 96.2 AFUE
D AC • Electric • 100% Cooling Load @ 13 SEER
D Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
□Test Status: Blower-door testedHouse is air-sealed as to achieve 1,334 CFM50 (5.00 ACH50) or less at final blower-door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
2018 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 5 CFM25 / 100 ft2
Total Leakage specified as: 8 CFM25 / 100 ft2 (Post-Construction)
3
Energy Code Inspection Checklist
Property
7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V
Community: WINDWARD AT LEGAC
WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED)
Organization TSI Energy Solutions
Devin Sielschott
Builder LENNAR HOMES
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors<= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC Mandatory, 2015 and 2018 IECC Prescriptive Paths:
Postconstruction Leakage Test: Total Duct Leakage<= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 and 2018 IECC Performance Paths (Cost Compliance):
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302
WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED)
General Building Information
Number Of Bedrooms Number Of Floors Conditioned Floor Area [sq ft]
Has Electric Vehicle Ready Space Unconditioned, attached garage?
Conditioned Volume [cu. ft.] Total Units in Building Residence Type
Floor Number Model Community Climate Zone
Foundation Wall
Foundation Wall Library List
Slab
Organization TSI Energy Solutions Devin Sielschott
Builder LENNAR HOMES
3
3 1,834
No Yes 16,012 1 Townhouse, inside unit
LOCKERBIE V WINDWARD AT LEGACY 1302 SA
None Present
None Present
Inspection Status Results are projected
Name Library Type Perimeter Floor Grade Carpet R Exposed Masonry Area
MAIN R-10, 2' down 40 On Grade 1.23 0
Slab Library List
Surface Area Location
37 4.0 ft' Exposed Exterior
Enclosing
Conditioned Space
Name Wall Construction Type Slab Completely Underslab Perimeter Insulated'? Insulation Width [ft) Insulation Depth [ft) Perimeter Insulation R Value Thermal Break Effective R-value
R-10, 2' down wood Frame I other No 0
Framed Floor
Name Library Type Carpet R
OVER GARAGE R-38, GR1 1.23
2 10
Floor Grade
Above Grade
Surface Area
386.0 ft'
Yes 0.00
Location
Unconditioned, attached garage
Organization TSI Energy Solutions Devin Sielschott
Builder LENNAR HOMES
Building Summary
Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302
WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED)
Framed Floor Library List
Name Effective R-value
R-38, GR1 33.825
Rim Joist
Name Library Type
COND/AMB G1 R-13, R-3.0
COND/COND G1 R-13, OSB
Rim Joist Library List
Name Effective Insulation R-value
G1 R-13, OSB 10.876
G1 R-13, R-3.0 13.575
Wall
Name Library Type
COND/AMB G1 R-13 BATT, R-3.0
COND/AMB 2X6 G1 R-19,R-3 02X6
COND/COND G1 R-22 DUPLEX COMMON
COND/GAR 2X6 G1 R-19, 2x6 GAR
Inspection Status Results are projected
Surface Area
72.0 IF
144.0 IF
Surface Color
Medium
Medium
Medium
Medium
Surface Area
670.0 ft'
170.0 ft'
1,592.0 ft'
160.0 ft'
Location
Exposed Exterior
Exposed Exterior
Location
Exposed Exterior
Exposed Exterior
Conditioned Space (Adiabatic)
Unconditioned, attached garage
2
Building Summary
Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302
WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED)
Wall Library List
Name
G1 R-13 BATT, R-3.0
G1 R-19, 2x6 GAR
G1 R-19, R-3.0 2X6
G1 R-22 DUPLEX COMMON
Glazing
Name Library Type
BACK U-.33, SHGC-.31
FRONT U-.33, SHGC-.31
FRONT2X6 U-.33, SHGC-.31
SLIDER u-.33. SHGC-.31
Glazing Library List
Name
U-.33, SHGC-.31
Skylight
Skylight Library List
Organization TSI Energy Solutions Devin Sielschott
Builder LENNAR HOMES
Effective R-value
15.12
16.218
20.217
18.407
Wall Foundation Assignment Wall Assignment
COND/AMB
COND/AMB
COND/AMB 2X6
COND/AMB
Shgc
0.31
None Present
None Present
Is Operable
Yes
Yes
Yes
Yes
Inspection Status Results are projected
Overhan� Overhang Ft To Overhan� Ft To Dept Top ottom
0 0 0
0 0 0
0 0 0
0 0 0
U-factor
0.330
Orientation Surface Area
East 70.0 ft'
West 45.0 ft'
West 78.0 ft'
East 33.0n'
3
Building Summary
Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302
WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED)
Opaque Door
Organization TSI Energy Solutions Devin Sielschott
Builder LENNAR HOMES
Name Library Type Wall Assignment Foundation Wall Assignment
FRONT Fiberglass/Steel COND/AMB 2X6 Door
GARAGE Fiberglass/Steel COND/GAR 2X6 Door
Opaque Door Library List
Name Effective LI-factor
Fiberglass/Steel Door 0.182
Roof Insulation
Inspection Status Results are projected
Emittance
0.9
0.9
Solar Surface Color Absorptance
0.75 Medium
0.75 Medium
Surface Area Location
20.0 ft' Exposed Exterior
18.0 ft' Exposed Exterior
Name Library Type Attic Exterior Area [ft'] Clay or Concrete Roof Tiles Surface Color Surface Area Location
SECOND R-38 Blown. GR 1 760
Roof Insulation Library List
Name Has Radiant Barrier
R-38 Blown. GR1 No
Whole House Infiltration
Infiltration Measurement Type
5ACH at 50 Pa Blower--0oor tested
Mechanical Ventilation
Ventilation Type
Exhaust Only
Ventilation Rate [ft'/ Operational hours per day Minute]
48.3 CFM (unmeasured) 24
No
Effective R-value
38.569
Shelter Class
4
Fan Watts
12watts
Medium 760.0 ft' Attic
Runs once every three Energy Recovery Percent hours
Yes o
4
Building Summary
Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302
WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED)
Lighting
% Interior Fluorescent Lighting % Interior LED Lighting
0 100
Onsite Generation
Organization TSI Energy Solutions Devin Sielschott
Builder LENNAR HOMES
% Exterior Fluorescent Lighting
0
None Present
Onsite Generation Library List
None Present
Solar Generation
None Present
Dehumidifier
None Present
Dehumidifier Library List
None Present
Conditioning Equipment
Name Library Type Heating Percent Load
AC PA 13NA036•N .. E• 0%
FURNACE 915SB42060E 17 100%
Water Heating ENT 50 100 0%
Inspection Status Results are projected
% Exterior LED Lighting
100
Cooling Percent Load
100%
0%
0%
% Garage Fluorescent Lighting
0
Hot Water Percent Load
0%
0%
100%
% Garage LED Lighting
100
Location
Conditioned Space
Conditioned Space
Conditioned Space
5
Building Summary
Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302
WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED)
Organization TSI Energy Solutions Devin Sielschott
Builder LENNAR HOMES
Equipment Type: 915S842060E17
Equipment Type Fuel Type Distribution Type
Motor Type Heating Efficiency Heating Capacity [kBtu/h] Use default EAE EAE [kWh]
Equipment Type: ENT 50 100
Equipment Type Fuel Type Distribution Type Hot Water Efficiency
Tank Capacity (gal) Hot Water Capacity [kBtu/h] Recovery Efficiency
Furnace
Natural Gas Forced Air
ECM (Variable Speed) 96.2AFUE 58 No 316
Residential Water Heater
Electric Hydronic Delivery (Radiant) 0.93 Energy Factor 50 15.4 0.98
Equipment Type: PA 13NA036*N**E*
Equipment Type Fuel Type Distribution Type Motor Type
Cooling Efficiency Cooling Capacity [kBtu/h]
Air Conditioner
Electric Forced Air PSC (Single Speed)
13 SEER 32.4
Inspection Status Results are projected
6
Building Summary
Property 7107EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302
WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED)
Distribution System
Distribution Type Heating Equipment Cooling Equipment
Sq Feet Served # Return Grilles Supply Duct R Value Return Duct R Value Supply Duct Area [fl']
Return Duct Area (f12] Leakage to Outdoors Total Leakage Total Leakage Duct Test Conditions
Use Default Flow Rate
Duct 1 Duct Location Percent Supply Area Percent Return Area Duct 2
Duct Location Percent Supply Area Percent Return Area Duct 3
Duct Location
Percent Supply Area Percent Return Area Duct 4 Duct Location Percent Supply Area Percent Return Area
Duct 5
Duct Location Percent Supply Area Percent Return Area Duct 6
Duct Location
Percent Supply Area Percent Return Area
Ceiling Fan
Has Ceiling Fan
Cfm Per Watt
Water Distribution
Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery?
Organization TSI Energy Solutions Devin Sielschott
Builder LENNAR HOMES
Forced Air
FURNACE AC
1,834
2 25 25 495.18
183.4 5 CFM25 / 100 ft2 146.72 CFM25 Post-Construction Yes
Conditioned Space 50 50
Altic (well vented, under insulation)50 50
Conditioned Space
0 0
Conditioned Space 0 0
Conditioned Space 0 0
Conditioned Space
0 0
No
100
Standard
No 79
No No 30 No
Inspection Status Results are projected
7
Building Summary
Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302
WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED)
Clothes Dryer
Cef Fuel Type Field Utilization
Is Outside Conditioned Space Clothes Dryer Available Defaults Type
Clothes Washer
Label Energy Rating Annual Gas Cost
Electric Rate Gas Rate Capacity lmef
Defaults Type Is Outside Conditioned Space Clothes Washer Available
Dishwasher
Dishwasher Efficiency Dishwasher Size Is Outside Conditioned Space
Appliances and Controls
Programmable thermostat? Range/Oven Fuel Convection Oven? Induction Range?
Range/Oven Outside Conditioned Space? Refrigerator Consumption Refrigerator Outside Conditioned Space?
Notes
Organization TSI Energy Solutions Devin Sielschott
Builder LENNAR HOMES
2.6173913
Electric Timer Controls
No Yes HERS Reference
704 kWh/Year
$23.00 S0.08/kWh SO 58/Therm 2.874 0.33052632 HERS Reference No Yes
270 kWh
Standard No
Yes
Electric No No
No 709 kWh/Year No
Inspection Status Results are projected
8