HomeMy WebLinkAboutWINDWARD AT LEGACY 1302 - WL1302(AS DESIGNED)[289600]2Indiana 2020 Performance Compliance Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community: WINDWARD AT LEGAC WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED) Organization TSI Energy Solutions Devin Sielschott Builder LENNAR HOMES Inspection Status Results are projected This report is based on a proposed design and does not confirm field enforcement of design elements. Annual Energy Cost Design Heating Cooling Water Heating Mechanical Ventilation Indiana 2020 Performance $467 $87 $350 $30 $934 $512 $0 $1,446 As Designed $458 $105 $350 SubTotal -Used to determine compliance Lights & Appliances w/out Ventilation Onsite generation Total Requirements 1105 1102.4.1.2 1102.5 1102.5 1104.1 Performance-based compliance passes by 1.1 % Air Leakage Testing Area-weighted average fenestration SHGC Area-weighted average fenestration U-Factor Lighting Equipment Efficiency Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. 1103.6 1103.6.1 Mechanical Ventilation Rate Mechanical Ventilation Efficacy Air sealing is 5.00 ACH at 50 Pa. It must not exceed 5.00 ACH at 50 Pa. Design exceeds requirements for Indiana 2020 Performance compliance by 1.1 %. $10 $924 $512 $0 $1,435 As a 3rd party extension of the code jurisdiction utilizing these reports. I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Devin Sielschott Organization: TSI Energy Solutions Digitally signed: 9/9/21 at 3:15 PM Ekotrope RATER -Version 3.2.4.2740 Indiana 2020 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm, including appropriate amendments. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 7107 EQUALITY BLVD CARMEL, IN 46032 Builder: LENNAR HOMES Model: LOCKERBIE V Community: WINDWARD AT LEGACY 1302 This report is based on a proposed design and does not confirm field enforcement of design elements. THIS HOME IS CERTIFIED TO MEET THE IN DIANA 2020 ENERGY CODE Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls N/A Framed Floor R-38 Building Features Duct Supply R-25.0, Return R-25.0 Duct Leakage to Outside 5 CFM25 I 100 ft2 Slab R-10.0 Perimeter, R-0.0Under Total Duct Leakage 8 CFM25 / 100 ft2 (Post-Construction) Heating Furnace• Natural Gas• 96.2 AFUE Cooling Air Conditioner• Electric• 13 SEER Infiltration 5 ACH50 Water Heating Residential Water Heater• Electric • 0.93 EnergyFactor Window U-Value: 0.33, SHGC: 0.31 As a 3rel party extension of tile code juriseliction utilizing these reports, I certify that this energy coele compliance Clocument has been created in accorelance with the requirements of Chapter 4 of the aelopted International Energy Conservation Coele based on Climate Zone 5. If rating is Projecteel, I certify that the building Clesign Clescribeel herein is consistent with the building plans, specifications, anel other calculations subnitteel with the permit application. If rating is Confirmeel, I certify that the aelelress referenceel above has been inspected/tested anel that the mandatory provisions of the IECC have been ins:alled to meet or exceeel the intent of the IECC or will be verifieel as such by another party. /:,�_,u,<�- Name: Organization: oevin Sielschott Signature: ot::>-= v'-".,,. __ _ TSI Energy Solutions Digitally signed: 9/9/21 at 3: 15 PM Ekotrope RAI ER - Version 3.2.4.2740 Indiana 2020 Certificate compliance results calculated using Ekotrope RATER's energy and code compliance algorithm, including appropriate amendments. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Energy Code Inspection Checklist Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community: WINDWARD AT LEGAC WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED) General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions Devin Sielschott Builder LENNAR HOMES 1,834 16,012 4,328 Inspection Status Results are projected The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab □Name: MAIN(374 s.f., 40 ft. exterior perimeter)R-10 perimeter insulation, R-0 under slab insulation. Framed Floor □Name: OVER GARAGE (386 s.f.)R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall None Present Above Grade Wall □ □ □ Name: COND/AMB (670 s.f.) R-3 continuous insulation, R-13 cavity insulationInsulation Grade: I Name: COND/AMB 2X6 (170 s.f.) R-3 continuous insulation, R-19 cavity insulationInsulation Grade: I Name: COND/GAR 2X6 (160 s.f.) R-0 continuous insulation, R-19 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community: WINDWARD AT LEGAC WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED) Name: COND/COND (1,592 s.f.) Organization TSI Energy Solutions Devin Sielschott Builder LENNAR HOMES □ R-0 continuous insulation, R-22 cavity insulationInsulation Grade: I Rim Joist □ □ Name: COND/AMB (72 s.f.)R: 13.575 Name: COND/COND (144 s.f.) R: 10.876 Ceiling/ Roof □Name: SECOND (760 s.f.)R-27.85 continuous insulation, R-10.15 cavity insulationInsulation Grade: I Opaque Door □ □ Name: FRONT (20 s.f.)U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected D Name: FRONT (45 s.f.), U: 0.330, SHGC: 0.31, Orientation: WEST D Name: FRONT 2X6 (78 s.f.), U: 0.330, SHGC: 0.31, Orientation: WEST D Name: BACK (70 s.f.), U: 0.330, SHGC: 0.31, Orientation: EAST D Name: SLIDER (33 s.f.), U: 0.330, SHGC: 0.31, Orientation: EAST Skylight None Present 2 Energy Code Inspection Checklist Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community: WINDWARD AT LEGAC WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED) Mechanical Ventilation Organization TSI Energy Solutions Devin Sielschott Builder LENNAR HOMES Inspection Status Results are projected □Mechanical ventilation system rated for, and capable of, providing continuous ventilation.System shall include automatic timing controls. System type: Exhaust Only, 24 hrs/day, 12 Watts Mechanical Equipment D FURNACE • Natural Gas • 100% Heating Load @ 96.2 AFUE D AC • Electric • 100% Cooling Load @ 13 SEER D Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control □Test Status: Blower-door testedHouse is air-sealed as to achieve 1,334 CFM50 (5.00 ACH50) or less at final blower-door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 2018 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Leakage to Outside specified as: 5 CFM25 / 100 ft2 Total Leakage specified as: 8 CFM25 / 100 ft2 (Post-Construction) 3 Energy Code Inspection Checklist Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community: WINDWARD AT LEGAC WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED) Organization TSI Energy Solutions Devin Sielschott Builder LENNAR HOMES Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors<= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Mandatory, 2015 and 2018 IECC Prescriptive Paths: Postconstruction Leakage Test: Total Duct Leakage<= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 and 2018 IECC Performance Paths (Cost Compliance): Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302 WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED) General Building Information Number Of Bedrooms Number Of Floors Conditioned Floor Area [sq ft] Has Electric Vehicle Ready Space Unconditioned, attached garage? Conditioned Volume [cu. ft.] Total Units in Building Residence Type Floor Number Model Community Climate Zone Foundation Wall Foundation Wall Library List Slab Organization TSI Energy Solutions Devin Sielschott Builder LENNAR HOMES 3 3 1,834 No Yes 16,012 1 Townhouse, inside unit LOCKERBIE V WINDWARD AT LEGACY 1302 SA None Present None Present Inspection Status Results are projected Name Library Type Perimeter Floor Grade Carpet R Exposed Masonry Area MAIN R-10, 2' down 40 On Grade 1.23 0 Slab Library List Surface Area Location 37 4.0 ft' Exposed Exterior Enclosing Conditioned Space Name Wall Construction Type Slab Completely Underslab Perimeter Insulated'? Insulation Width [ft) Insulation Depth [ft) Perimeter Insulation R Value Thermal Break Effective R-value R-10, 2' down wood Frame I other No 0 Framed Floor Name Library Type Carpet R OVER GARAGE R-38, GR1 1.23 2 10 Floor Grade Above Grade Surface Area 386.0 ft' Yes 0.00 Location Unconditioned, attached garage Organization TSI Energy Solutions Devin Sielschott Builder LENNAR HOMES Building Summary Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302 WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED) Framed Floor Library List Name Effective R-value R-38, GR1 33.825 Rim Joist Name Library Type COND/AMB G1 R-13, R-3.0 COND/COND G1 R-13, OSB Rim Joist Library List Name Effective Insulation R-value G1 R-13, OSB 10.876 G1 R-13, R-3.0 13.575 Wall Name Library Type COND/AMB G1 R-13 BATT, R-3.0 COND/AMB 2X6 G1 R-19,R-3 02X6 COND/COND G1 R-22 DUPLEX COMMON COND/GAR 2X6 G1 R-19, 2x6 GAR Inspection Status Results are projected Surface Area 72.0 IF 144.0 IF Surface Color Medium Medium Medium Medium Surface Area 670.0 ft' 170.0 ft' 1,592.0 ft' 160.0 ft' Location Exposed Exterior Exposed Exterior Location Exposed Exterior Exposed Exterior Conditioned Space (Adiabatic) Unconditioned, attached garage 2 Building Summary Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302 WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED) Wall Library List Name G1 R-13 BATT, R-3.0 G1 R-19, 2x6 GAR G1 R-19, R-3.0 2X6 G1 R-22 DUPLEX COMMON Glazing Name Library Type BACK U-.33, SHGC-.31 FRONT U-.33, SHGC-.31 FRONT2X6 U-.33, SHGC-.31 SLIDER u-.33. SHGC-.31 Glazing Library List Name U-.33, SHGC-.31 Skylight Skylight Library List Organization TSI Energy Solutions Devin Sielschott Builder LENNAR HOMES Effective R-value 15.12 16.218 20.217 18.407 Wall Foundation Assignment Wall Assignment COND/AMB COND/AMB COND/AMB 2X6 COND/AMB Shgc 0.31 None Present None Present Is Operable Yes Yes Yes Yes Inspection Status Results are projected Overhan� Overhang Ft To Overhan� Ft To Dept Top ottom 0 0 0 0 0 0 0 0 0 0 0 0 U-factor 0.330 Orientation Surface Area East 70.0 ft' West 45.0 ft' West 78.0 ft' East 33.0n' 3 Building Summary Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302 WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED) Opaque Door Organization TSI Energy Solutions Devin Sielschott Builder LENNAR HOMES Name Library Type Wall Assignment Foundation Wall Assignment FRONT Fiberglass/Steel COND/AMB 2X6 Door GARAGE Fiberglass/Steel COND/GAR 2X6 Door Opaque Door Library List Name Effective LI-factor Fiberglass/Steel Door 0.182 Roof Insulation Inspection Status Results are projected Emittance 0.9 0.9 Solar Surface Color Absorptance 0.75 Medium 0.75 Medium Surface Area Location 20.0 ft' Exposed Exterior 18.0 ft' Exposed Exterior Name Library Type Attic Exterior Area [ft'] Clay or Concrete Roof Tiles Surface Color Surface Area Location SECOND R-38 Blown. GR 1 760 Roof Insulation Library List Name Has Radiant Barrier R-38 Blown. GR1 No Whole House Infiltration Infiltration Measurement Type 5ACH at 50 Pa Blower--0oor tested Mechanical Ventilation Ventilation Type Exhaust Only Ventilation Rate [ft'/ Operational hours per day Minute] 48.3 CFM (unmeasured) 24 No Effective R-value 38.569 Shelter Class 4 Fan Watts 12watts Medium 760.0 ft' Attic Runs once every three Energy Recovery Percent hours Yes o 4 Building Summary Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302 WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED) Lighting % Interior Fluorescent Lighting % Interior LED Lighting 0 100 Onsite Generation Organization TSI Energy Solutions Devin Sielschott Builder LENNAR HOMES % Exterior Fluorescent Lighting 0 None Present Onsite Generation Library List None Present Solar Generation None Present Dehumidifier None Present Dehumidifier Library List None Present Conditioning Equipment Name Library Type Heating Percent Load AC PA 13NA036•N .. E• 0% FURNACE 915SB42060E 17 100% Water Heating ENT 50 100 0% Inspection Status Results are projected % Exterior LED Lighting 100 Cooling Percent Load 100% 0% 0% % Garage Fluorescent Lighting 0 Hot Water Percent Load 0% 0% 100% % Garage LED Lighting 100 Location Conditioned Space Conditioned Space Conditioned Space 5 Building Summary Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302 WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED) Organization TSI Energy Solutions Devin Sielschott Builder LENNAR HOMES Equipment Type: 915S842060E17 Equipment Type Fuel Type Distribution Type Motor Type Heating Efficiency Heating Capacity [kBtu/h] Use default EAE EAE [kWh] Equipment Type: ENT 50 100 Equipment Type Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal) Hot Water Capacity [kBtu/h] Recovery Efficiency Furnace Natural Gas Forced Air ECM (Variable Speed) 96.2AFUE 58 No 316 Residential Water Heater Electric Hydronic Delivery (Radiant) 0.93 Energy Factor 50 15.4 0.98 Equipment Type: PA 13NA036*N**E* Equipment Type Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtu/h] Air Conditioner Electric Forced Air PSC (Single Speed) 13 SEER 32.4 Inspection Status Results are projected 6 Building Summary Property 7107EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302 WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED) Distribution System Distribution Type Heating Equipment Cooling Equipment Sq Feet Served # Return Grilles Supply Duct R Value Return Duct R Value Supply Duct Area [fl'] Return Duct Area (f12] Leakage to Outdoors Total Leakage Total Leakage Duct Test Conditions Use Default Flow Rate Duct 1 Duct Location Percent Supply Area Percent Return Area Duct 2 Duct Location Percent Supply Area Percent Return Area Duct 3 Duct Location Percent Supply Area Percent Return Area Duct 4 Duct Location Percent Supply Area Percent Return Area Duct 5 Duct Location Percent Supply Area Percent Return Area Duct 6 Duct Location Percent Supply Area Percent Return Area Ceiling Fan Has Ceiling Fan Cfm Per Watt Water Distribution Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Organization TSI Energy Solutions Devin Sielschott Builder LENNAR HOMES Forced Air FURNACE AC 1,834 2 25 25 495.18 183.4 5 CFM25 / 100 ft2 146.72 CFM25 Post-Construction Yes Conditioned Space 50 50 Altic (well vented, under insulation)50 50 Conditioned Space 0 0 Conditioned Space 0 0 Conditioned Space 0 0 Conditioned Space 0 0 No 100 Standard No 79 No No 30 No Inspection Status Results are projected 7 Building Summary Property 7107 EQUALITY BLVD CARMEL, IN 46032 Model: LOCKERBIE V Community WINDWARD AT LEGACY 1302 WINDWARD AT LEGACY 1302 WL 1302(AS DESIGNED) Clothes Dryer Cef Fuel Type Field Utilization Is Outside Conditioned Space Clothes Dryer Available Defaults Type Clothes Washer Label Energy Rating Annual Gas Cost Electric Rate Gas Rate Capacity lmef Defaults Type Is Outside Conditioned Space Clothes Washer Available Dishwasher Dishwasher Efficiency Dishwasher Size Is Outside Conditioned Space Appliances and Controls Programmable thermostat? Range/Oven Fuel Convection Oven? Induction Range? Range/Oven Outside Conditioned Space? Refrigerator Consumption Refrigerator Outside Conditioned Space? Notes Organization TSI Energy Solutions Devin Sielschott Builder LENNAR HOMES 2.6173913 Electric Timer Controls No Yes HERS Reference 704 kWh/Year $23.00 S0.08/kWh SO 58/Therm 2.874 0.33052632 HERS Reference No Yes 270 kWh Standard No Yes Electric No No No 709 kWh/Year No Inspection Status Results are projected 8