HomeMy WebLinkAboutA010.1A101
FLOOR PLAN,
ENLARGED PLANS,
INTERIOR ELEVATIONS
A
PROJECT AREA FLOOR PLAN
SCALE: 3/16" = 1'-0"1N
101
PROJECT NUMBER:2021-049CARMEL, IN 4603310.27.2021
CERTIFICATION:SITE ARCHITECTUREarchitecture + landscape architectureDATE ISSUED:
REVISIONS ISSUED:ATI PHYSICAL THERAPY4765 EAST 126TH STREETARCHITECT:
SITE ARCHITECTURE
architecture + landscape architecture
BRAD SMITH, RA | LEED AP
13144 EAST 186TH STREET
NOBLESVILLE, IN. 46060
PH: 317.374.8720
E-MAIL: brad@site-architecture.com
PROJECT CONTACT:TENANT IMPROVEMENTThese drawings are intended for the purposes
State of Indiana/City of Carmel plan review,
permitting, bidding, and construction.
CONSTRUCTION DOCUMENTS
MEP ENGINEER:
PHIL HIX
2707 RAND ROAD
INDIANAPOLIS, IN. 46241
317.281.6342
phix@daengineering.com
PROJECT CONTACT:
DESIGN-AIRE
ENGINEERING, INC.
GENERAL PLAN NOTES:
A. PROVIDE PHYSICAL SAMPLES AND SHOP DRAWINGS FOR ALL NEW
INTERIOR AND EXTERIOR FINISH MATERIALS TO ARCHITECT FOR
REVIEW / APPROVAL PRIOR TO ORDERING, FABRICATION, AND
INSTALLATION.
B. NOTIFY ARCHITECT OF ANY DIMENSIONAL OR PHYSICAL
DISCREPANCIES BETWEEN THE DRAWINGS FOR CLARIFICATION
PRIOR TO PROCEEDING WITH WORK IN THE AFFECTED AREA.
FLOOR PLAN / ELEVATION NOTES:X
4. INDIVIDUAL FRAMELESS ADA COMPLIANT MIRROR TO BE
CENTERED ABOVE LAVATORY. BOBRICK B-165 2436 OR APPROVED
EQUAL. SEE INTERIOR ELEVATIONS.
9. SURFACE MOUNTED ADA COMPLIANT DOUBLE ROLL TOILET
TISSUE DISPENSER. (BOBRICK B-7686 - OR EQUAL).
6. NEW WALL MOUNTED ADA GRAB BAR - 36" HORIZONTAL - 1.5" DIA.
(BOBRICK B6806 SERIES - OR EQUAL)
7. NEW WALL MOUNTED ADA GRAB BAR - 42" HORIZONTAL - 1.5" DIA.
(BOBRICK B6806 SERIES - OR EQUAL)
8. NEW WALL MOUNTED ADA GRAB BAR - 18" VERTICAL - 1.5" DIA.
(BOBRICK B6806 SERIES - OR EQUAL)
2. WALL MOUNTED ADA COMPLIANT LAVATORY FIXTURE AND
FAUCET, SEE PLUMBING DRAWINGS. PROVIDE REQUIRED ADA
SCALD GUARD PROTECTION FOR WASTE AND SUPPLY LINES.
3. SURFACE MOUNTED ADA COMPLIANT SOAP DISPENSER.
(BOBRICK B-4112 - OR EQUAL).
5. FLOOR MOUNTED ADA COMPLIANT TOILET FIXTURE, SEE
PLUMBING DRAWINGS.
10. 5'-0" ADA CIRCLE CLEARANCE AREA - SHOWN FOR REFERENCE
ONLY. NOT A FLOOR PATTERN.
11. 2'-6" X 4'-0" ADA SINK CLEARANCE AREA - SHOWN FOR REFERENCE
ONLY. NOT A FLOOR PATTERN.
12. 5'-0" X 5'-0" ADA TOILET CLEARANCE AREA - SHOWN FOR
REFERENCE ONLY. NOT A FLOOR PATTERN.
13. VINYL BASE, SEE FINISH PLAN AND SCHEDULE.
1. SURFACE MOUNTED PAPER TOWEL DISPENSER - BOBRICK B-262
OR APPROVED EQUAL.
14. FLOOR MOP SINK, SEE PLUMBING DRAWINGS.
15. DUAL-HEIGHT DRINKING FOUNTAIN, SEE PLUMBING DRAWINGS.
MOUNTING HEIGHT TO COMPLY WITH ADA STANDARDS.
16. NOT USED.
17. SOLID SURFACE SILL - WHITE.
18. EXISTING BRICK SILL TO REMAIN. PAINT TO MATCH ADJACENT
TOUCH UP PAINT AFTER WINDOW/DOOR INSTALLATION TO MATCH
EXISTING.
19. NEW ALUMINUM STOREFRONT WINDOW. MATCH EXISTING
MULLION FINISH. SEE FRAME ELEVATIONS.
20. NEW ALUMINUM STOREFRONT DOOR. MATCH EXISTING
MULLION FINISH. SEE DOOR ELEVATIONS AND SCHEDULE.
21. SEE PLUMBING DRAWINGS FOR SINK ROUGH-IN. SINK TO BE
INSTALLED AS PART OF TENANT WORK PACKAGE.
22. CLEAN EXISTING INTERIOR CONCRETE SLAB PRIOR TO PROJECT
COMPLETION.
23. COMBINED CONCRETE CURB AND WALK. SEE DETAILS THIS
SHEET.
24. CONCRETE EXPANSION JOINT, SEE DETAIL THIS SHEET.
25. NEW CONCRETE SLAB TO BE WITHIN 1/2" OF FINISHED FLOOR
HEIGHT.
26. LINE OF EXISTING CURB. NEW CURB TO BE IN LINE WITH EXISTING
CURB. TOP AND BOTTOM OF CURB TO MEET EXISTING GRADE.
27. EXISTING STOREFRONT WINDOW TO REMAIN.
28. EXISTING STEEL COLUMN TO REMAIN.
29. SEMI-RECESSED FIRE EXTINGUISHER CABINET AND FIRE
EXTINGUISHER. SEE LIFE SAFETY PLAN.
30. WATER SUPPLY/DRAIN BOX FOR WASHING MACHINE. SEE
PLUMBING DRAWINGS.
31. TENANT SIGNAGE AREA. TENANT TO COORDINATE WITH
LANDLORD AND CITY OF CARMEL FOR NEW SIGNAGE APPROVAL.
32. CONCRETE ISOLATION JOINT, SEE DETAIL THIS SHEET
33. CONCRETE CONTROL JOINT, SEE DETAIL THIS SHEET
34. DOOR AND FRAME, SEE DOOR SCHEDULE.
ENLERGED PLAN
SCALE: 1/2" = 1'-0"3
ADJACENT EXISTING TENANT
HATCHED AREA NOT
IN PROJECT SCOPE
M OCCUPANCY
(GROCERY STORE)
OPEN
TREATMENT
AREA
101
TREATMENT
103
CORR.
102
RR
105
LAUNDRY /
MECH.
104
RR
105
LAUNDRY /
MECH.
104
A101
3
A102
1105
103104
INTERIOR ELEV.
SCALE: 1/2" = 1'-0"43'-6"3'-0"4 32
1'-5"
2'-0"
13 2'-11"3'-4"1'-6"1'-6"6"3'-0"
6 5 9
P1
8
7
VB2
1'-6"
INTERIOR ELEV.
SCALE: 1/2" = 1'-0"51'-6"2'-11"3'-4"1'-6"1'-0"3'-6"
5
9 8 7
6
P2
13
VB2
5/A101
4/A1015
6
987
12
10
3
2
4
11
1
1'-5"1'-6"14
15
17W3W3
W2W2W221
5"22 22
34
34
W1W1
W1W1W1W1 W1W1W1
W1W6
W1
21'-8 3/4"1'-2 1/8"7'-0 7/8"7'-6 7/8"11'-6 7/8"36'-4 3/4"2'-5"
1'-9 7/8"
11'-7 1/2"6"3'-0"29'-8 1/2"9 1/4"3 3/4"
RR
106
3 5/8"
6'-10 7/8"80'-4"2'-9 3/4"11'-1 3/4"11'-3 1/8"
112'-5 1/2"
ADJACENT PROPOSED TENANT
HATCHED AREA NOT
IN PROJECT SCOPE
A-2 OCCUPANCY
(RESTAURANT)
ADJACENT EXISTING TENANT
HATCHED AREA NOT
IN PROJECT SCOPE
M OCCUPANCY
(GROCERY STORE)6'-1 5/8"1'-11 5/8"3'-4"4'-0 5/8"6'-2"21'-7 5/8"ALIGN8'-11"4'-7 1/4"5'-6 7/8"2'-2"4 3/4"ALIGN ALIGN ALIGN1'-7"6"2'-9 3/4"6'-2 5/8"3'-4"
8 3/8"
5'-4 3/8"6'-9 1/2"
RR
106
1065/A101
O.H.4/A101O.H.5
6
9 8 7
12
10
3
2
4
11
1
1'-5"1'-6"W1
W14'-5 5/8"8 3/8"6'-8 1/4"6"6'-8 1/4"8 3/8"1'-6 1/8"
7'-10 5/8"7'-4 5/8"6'-1 5/8"1'-11 5/8"2'-1 3/4"5'-6 7/8"EQ EQ2'-10"1'-5"W4W4W4
W5
W2W2W5W5W4W4 A201
1W5W5
W2WALL TYPES:
W1
6"5/8"5/8"W2 3 5/8"5/8"5/8"3 5/8" METAL STUDS AT 16" O.C. ON
BOTH SIDES OF WALL, INSTALL 1
LAYER OF 5/8" GYPSUM BOARD.
TERMINATE STUDS AND GYP. BD. 6"
ABOVE CEILING. SEE CEILING PLAN.
BRACE STUDS TO STRUCTURE ABOVE
AT 4'-0" O.C. MINIMUM FOR LATERAL
STABILITY.
USE MOISTURE RESISTANT GYP. BD.
IN RESTROOM AREAS. FINISH TO
LEVEL 4 DRYWALL FINISH - PRIME PER
FINISH SCHEDULE SO THAT WALLS
ARE PAINT READY FOR TENANT.
6" METAL STUDS AT 16" O.C. ON BOTH
SIDES OF WALL, INSTALL 1 LAYER OF
5/8" TYPE X GYPSUM BOARD.
-EXTEND STUDS AND GYP. BD. TO
BOTTOM OF DECK ABOVE.
-PROVIDE FIRE CAULKING AT
BASE/TOP OF WALL AND AT ANY
PENETRATIONS TO MAINTAIN 1 HOUR
RATING.
-PROVIDE CONTINUOUS SOUND BATT
INSULATION (STC 55 MIN.) BETWEEN
STUDS FROM FLOOR TO
STRUCTURE ABOVE.
-AT PERIMETER (TOP, BOTTOM,
SIDES) OF WALL, PROVIDE VAPOR
BARRIER SET IN SEALANT AT EDGE
OF WALL ASSEMBLY BENEATH
GYPSUM BOARD FOR ODOR
CONTROL.
-ON ATI SIDE OF WALL, FINISH TO
LEVEL 4 DRYWALL FINISH - PRIME
PER FINISH SCHEDULE SO THAT
WALLS ARE PAINT READY FOR
TENANT. TAPE AND FINISH ON
FUTURE TENANT (EAST) SIDE OF
WALL.
W3
3 5/8"5/8"1 HOUR FIRE RATED DEMISING WALL
EXISTING WALL WITH GYPSUM BOARD
FINISH TO REMAIN IN PLACE.
FINISH TO LEVEL 4 FINISH AND PRIME
PER FINISH SCHEDULE SO THAT
WALLS ARE PAINT READY FOR
TENANT.
INTERIOR FINISH SPACE
EXISTING WALL
EXISTING
GYPSUM BOARD
W4
W5
3 5/8"5/8"3 5/8" METAL STUDS AT 16" O.C. ON
ATI / ROOM FINISH SIDE OF WALL,
INSTALL 1 LAYER OF 5/8" TYPE X
GYPSUM BOARD.
-EXTEND STUDS AND GYP. BD. TO
BOTTOM OF DECK ABOVE.
-PROVIDE CONTINUOUS SOUND BATT
INSULATION (STC 55 MIN.) BETWEEN
STUDS FROM FLOOR TO
STRUCTURE ABOVE.
-AT PERIMETER (TOP, BOTTOM,
SIDES) OF WALL, PROVIDE VAPOR
BARRIER SET IN SEALANT AT EDGE
OF WALL ASSEMBLY BENEATH
GYPSUM BOARD FOR ODOR
CONTROL.
-ON ATI SIDE OF WALL, FINISH TO
LEVEL 4 DRYWALL FINISH - PRIME
PER FINISH SCHEDULE SO THAT
WALLS ARE PAINT READY FOR
TENANT.
-FINISH GYPSUM BOARD FLUSH WITH
ADJACENT/EXISTING GYPSUM
BOARD ALREADY IN PLACE
DEMISING WALL FUR OUT
3 5/8" METAL STUDS AT 16" O.C. ON
BOTH SIDES OF WALL, INSTALL 1
LAYER OF 5/8" GYPSUM BOARD.
TERMINATE STUDS AND GYP. BD. 6"
ABOVE CEILING. SEE CEILING PLAN.
BRACE STUDS TO STRUCTURE ABOVE
AT 4'-0" O.C. MINIMUM FOR LATERAL
STABILITY.
FINISH TO LEVEL 4 DRYWALL FINISH -
PRIME PER FINISH SCHEDULE SO
THAT WALLS ARE PAINT READY FOR
TENANT.
W6
5/8"6" METAL STUDS AT 16" O.C. ON BOTH
SIDES OF WALL, INSTALL 1 LAYER OF
5/8" GYPSUM BOARD. TERMINATE
STUDS AND GYP. BD. 6" ABOVE
CEILING. SEE CEILING PLAN. BRACE
STUDS TO STRUCTURE ABOVE AT 4'-0"
O.C. MINIMUM FOR LATERAL
STABILITY.
USE MOISTURE RESISTANT GYP. BD.
IN RESTROOM AREAS. FINISH TO
LEVEL 4 DRYWALL FINISH - PRIME PER
FINISH SCHEDULE SO THAT WALLS
ARE PAINT READY FOR TENANT.6"5/8"27
18
28
28
29
29
30
3434W4