HomeMy WebLinkAboutA010.3A111
REFLECTED CEILING
PLAN, FINISH PLAN,
+ SCHEDULEPROJECT AREA CEILING PLAN
SCALE: 3/16" = 1'-0"1N
PROJECT NUMBER:2021-049CARMEL, IN 4603310.27.2021
CERTIFICATION:SITE ARCHITECTUREarchitecture + landscape architectureDATE ISSUED:
REVISIONS ISSUED:ATI PHYSICAL THERAPY4765 EAST 126TH STREETARCHITECT:
SITE ARCHITECTURE
architecture + landscape architecture
BRAD SMITH, RA | LEED AP
13144 EAST 186TH STREET
NOBLESVILLE, IN. 46060
PH: 317.374.8720
E-MAIL: brad@site-architecture.com
PROJECT CONTACT:TENANT IMPROVEMENTThese drawings are intended for the purposes
State of Indiana/City of Carmel plan review,
permitting, bidding, and construction.
CONSTRUCTION DOCUMENTS
MEP ENGINEER:
PHIL HIX
2707 RAND ROAD
INDIANAPOLIS, IN. 46241
317.281.6342
phix@daengineering.com
PROJECT CONTACT:
DESIGN-AIRE
ENGINEERING, INC.
OPEN
TREATMENT
AREA
101TREATMENT
103
CORRIDOR
102
RR
105
LAUNDRY /
MECH.
104
A. ALL ACOUSTICAL CEILING GRIDS ARE TO BE CENTERED IN
ROOM UNLESS NOTED OTHERWISE.
B. REFER TO CEILING PLAN FOR ALL CEILING HEIGHTS.
C. THE ARCHITECTURAL CEILING PLANS SHALL GOVERN THE
LAYOUT OF ALL CEILING ELEMENTS AND/OR PENETRATIONS.
COORDINATE WITH THE ARCHITECT ANY FIELD VERIFIED OR
AS BUILT CONDITIONS THAT DIFFER FROM WHAT IS SHOWN
ON THE DRAWINGS.
D. SEE MEP DRAWINGS FOR LIGHT FIXTURE AND DIFFUSER
LOCATIONS. LIGHT FIXTURES ARE SHOWN FOR REFERENCE
ONLY ON ARCHITECTURAL REFLECTED CEILING PLAN.
NOTIFY ARCHITECT OF ANY DISCREPANCIES.
RCP GENERAL NOTES:
CEILING LEGEND:
CEILING MATERIAL A
CEILING HEIGHT 9'-0"
2X4 ACOUSTICAL CEILING TILE
WITH CENTER REVEAL TO CREATE 2X2 SQUARES
CEILING TYPES:
A.24" X 48" LAY IN CEILING TILE AND GRID
BASIS OF DESIGN:
MANUFACTURER: ARMSTRONG
PRODUCT: 755A, 5/8" THICK
PANEL COLOR: WHITE
GRID: 15/16"
GRID COLOR: WHITE
NRC: 0.50
FIRE RATING: CLASS A
-OR APPROVED EQUAL AS DETERMINED BY ARCHITECT
RCP NOTES:CX
E. PROVIDE PHYSICAL SAMPLES AND SHOP DRAWINGS FOR ALL NEW
INTERIOR FINISH MATERIALS TO ARCHITECT FOR REVIEW/
APPROVAL PRIOR TO ORDERING/FABRICATION AND INSTALLATION.
F. IF ACTUAL ROOM DIMENSIONS VARY RELATIVE TO ACOUSTIC
CEILING GRID LAYOUT, DO NOT INSTALL WITH SLIVERS OF
ACOUSTIC PANEL/GRID LESS THAN 4" FROM PERIMETER OF WALL.
IF LAYOUT TO CENTER GRIDS IS CLOSE TO WALL, COORDINATE
WITH ARCHITECT TO ADJUST GRID/SPACING SO THAT SLIVERS
OF ACOUSTIC GRID ARE NOT LEFT AS PART OF FINISH CEILING.
C1. BULKHEAD. 5/8" GYP. BD. ON EACH SIDE OF 3-5/8" STEEL STUD
FRAMING. EXTEND GYP. BD. TO 6" ABOVE FINISHED CEILING.
PAINT PER FINISH SCHEDULE.
C19'-0"
A
9'-0"
A
9'-0"
A
10'-0"
A
10'-0"
A
PROJECT AREA FINISH PLAN
SCALE: 3/16" = 1'-0"2N
OPEN
TREATMENT
AREA
101
TREATMENT
103
CORRIDOR
102
RR
105
LAUNDRY /
MECH.
104
FL 1
P
-
3
-
FL1 TYPE: EXISTING CONCRETE FLOOR. FINISH TO BE PROVIDED
BY TENANT. CLEAN PRIOR TO PROJECT COMPLETION.
FLOORFLX
P
VB
X
X
FINISH SCHEDULE:
FL2
MFG: ARMSTRONG
PRODUCT: EXCELON IMPERIAL TEXTURE
COLOR: CHARCOAL
SIZE: 12" X 12"
TYPE: VINYL COMPOSITION TILE
INSTALL: 1/4 TURN
WALL
P1
MFG: SHERWIN WILLIAMS 200
COLOR: GRAY MATTERS SW7066 (EGGSHELL FINISH)
TYPE: LATEX PAINTP2
FL X
P
VB
X
X
MFG: RUST-OLEUM 5300 (OR APPROVED EQUAL)
COLOR: MATCH SHERWIN WILLIAMS "WEB GRAY SW7075"
TYPE: 2-PART EPOXY PAINT
SHEEN: GLOSS
APPLICATION: 1 COAT PRIMER, 2 COATS FINISH
APPLICATION: 1 COAT PRIMER, 2 COATS FINISH
TYPE: LATEX PAINTP3
WALLS TO RECEIVE 1 COAT PRIMER ONLY.
VB1
MFG: VPI
COLOR: GRAPHITE
TYPE: VINYL COVE WALL BASE
SIZE: 4"
BASEFLX
P
VB
X
X
VB2
MFG: VPI
COLOR: GRAPHITE
TYPE: VINYL COVE WALL BASE
SIZE: 6"
FINISH PLAN SYMBOLS:X
WALL FINISH TAG
(DENOTES DIFFERENT WALL FINISH LOCATIONS)
FLOORING TRANSITION
ROOM FINISH TAG
FLOOR FINISH
WALL FINISH
BASE FINISH
REMARKS
XXX
XXX XXX
FL X
P
VB
X
X
FL 2
P
VB
2
2
FL 1
P
-
3
-
FL 1
P
-
3
-
FL 2
P
VB
2
1
P1
RR
106
FL 2
P
VB
2
2
ADJACENT EXISTING TENANT
HATCHED AREA NOT
IN PROJECT SCOPE
M OCCUPANCY
(GROCERY STORE)
ADJACENT PROPOSED TENANT
HATCHED AREA NOT
IN PROJECT SCOPE
A-2 OCCUPANCY
(RESTAURANT)
ADJACENT PROPOSED TENANT
HATCHED AREA NOT
IN PROJECT SCOPE
A-2 OCCUPANCY
(RESTAURANT)
ADJACENT EXISTING TENANT
HATCHED AREA NOT
IN PROJECT SCOPE
M OCCUPANCY
(GROCERY STORE)
RR
106
9'-0"
A
9'-0"
A
C2. LIGHT FIXTURE. SEE ELECTRICAL DRAWINGS.
C2
C2
C2C2C2C2C2C2C2C2C2C2C2
C2C2
C2 C2 C2 C2 C2 C2 C2 C2 C2 C2
C2C2C2C2C2C2C2C2C2
C2C2
C2
C2
C2
C2 C2
P1
C2