Loading...
HomeMy WebLinkAboutGN010.1G002 CODE SUMMARY + LIFE SAFETY PLAN LIFE SAFETY PLAN SCALE: 3/16" = 1'-0"1N PROJECT NUMBER:2021-049CARMEL, IN 4603310.27.2021 CERTIFICATION:SITE ARCHITECTUREarchitecture + landscape architectureDATE ISSUED: REVISIONS ISSUED:ATI PHYSICAL THERAPY4765 EAST 126TH STREETARCHITECT: SITE ARCHITECTURE architecture + landscape architecture BRAD SMITH, RA | LEED AP 13144 EAST 186TH STREET NOBLESVILLE, IN. 46060 PH: 317.374.8720 E-MAIL: brad@site-architecture.com PROJECT CONTACT:TENANT IMPROVEMENTThese drawings are intended for the purposes State of Indiana/City of Carmel plan review, permitting, bidding, and construction. CONSTRUCTION DOCUMENTS MEP ENGINEER: PHIL HIX 2707 RAND ROAD INDIANAPOLIS, IN. 46241 317.281.6342 phix@daengineering.com PROJECT CONTACT: DESIGN-AIRE ENGINEERING, INC. EXIT OPEN TREATMENT AREA 101TREATMENT 103 CORR. 102 RR 105 LAUNDRY / MECH. 104 SEMI-RECESSED FIRE EXTINGUISHER CABINET AND FIRE EXTINGUISHER. F BUILDING INFO/CODE SUMMARY PROJECT SCOPE INFORMATION BUILDING AREA CONSTRUCTION TYPE OCCUPANCY IIB - FULLY SPRINKLERED OCCUPANT LOAD EGRESS -InIBC 2014 - TABLE 1015.1 B OCCUPANCY 22 PEOPLE < 49 -ONLY 1 EXIT REQUIRED - COMPLIES -InIBC 2014 - 1007.1 ACCESSIBLE MEANS OF EGRESS 1 ACCESSIBLE MEANS OF EGRESS REQUIRED - 1 PROVIDED - COMPLIES -InIBC 2014 - 1016.2 TRAVEL DISTANCE B OCCUPANCY WITH SPRINKER = 300' -MAX TRAVEL DISTANCE = 125' < 300' - COMPLIES PLUMBING FIXTURES -InIBC 2014 - 2902.1 - NUMBER OF FIXTURES - B OCCUPANCY -WATER CLOSETS = 1 PER 25 FOR FIRST 50 (MALE AND FEMALE COMBINED) OCCUPANCY = 22 / 2 11 MALE < 25 - 1 REQUIRED -1 PROVIDED - COMPLIES 11 FEMALE < 25 - 1 REQUIRED -1 PROVIDED - COMPLIES -LAVATORIES = 1 PER 40 FOR THE FIRST 80 REQUIRED 11 MALE - 1 PROVIDED - COMPLIES 22 FEMALE - 1 PROVIDED - COMPLIES InIBC 2014 2902.2 OCCUPANT LOAD = 22 > 15 SEPARATE MALE/FEMALE FACILITIES REQUIRED - 2 PROVIDED - COMPLIES -DRINKING FOUNTAINS = 1 PER 100 REQUIRED -22 < 100 - 1 REQUIRED -2 PROVIDED - COMPLIES -SERVICE SINK = 1 REQUIRED, 1 PROVIDED -COMPLIES FIRE PROTECTION -SPRINKLER SYSTEM -BUILDING IS FULLY SPRINKLERED -FIRE ALARM -PER InIBC 2014 - 907.2.2 - GROUP B -NO REQUIREMENTS APPLY TO THIS PROJECT. -NO FIRE ALARM REQUIRED. TOTAL OCCUPANT LOAD = 22 PEOPLE FIRE EXTINGUISHER NOTE: CONFIRM LOCATION OF FIRE EXTINGUISHERS WITH ARCHITECT AND CARMEL FIRE DEPT. EXTINGUISHERS TO BE MINIMUM 5 POUND ABC RATED EXTINGUISHERS - WALL MOUNTED NOT HIGHER THAN 5 FEET FROM THE FLOOR TO THE TOP OF THE UNIT. EXTINGUISHERS SHALL BE SERVICED ANNUALLY BY A FIRE EXTINGUISHER COMPANY. -OVERALL BUILDING AREA =43,599 S.F. B OCCUPANCY -PROFESSIONAL SERVICES - PHYSICAL THERAPY BUSINESS AREA = 2,091 S.F. LIFE SAFETY KEY EXIT PATH CEILING MOUNTED SMOKE DETECTORS (GENERAL LOCATION IS INDICATED - CONTRACTOR VERIFY SPECIFIC LOCATION WITH ARCHITECT PRIOR TO INSTALLATION) THIS PROJECT SCOPE INCLUDES INTERIOR DEMISING AND TENANT FINISH WORK WITHIN AN EXISTING BUILDING. -TENANT FINISH PROJECT SCOPE AREA =2,527 S.F. 2,091 S.F. / 100 S.F. GROSS = 20.91 = 21 PEOPLE MECHANICAL / UTILITY AREA = 200 S.F. 200 S.F. / 300 S.F. GROSS = 0.67 = 1 PERSON SEPARATION OF OCCUPANCIES -InIBC 2014 - TABLE 508.4 PROJECT SCOPE AREA = B OCCUPANCY SPRINKLERED EXISTING ADJACENT TENANT WEST = M OCCUPANCY SPRINKLERED -NO RATED SEPARATION REQUIRED PROJECT SCOPE AREA = B OCCUPANCY SPRINKLERED PROPOSED ADJACENT TENANT EAST= A-2 OCCUPANCY SPRINKLERED -1 HOUR RATED SEPARATE REQUIRED -1 HOUR DEMISING WALL PROVIDED -COMPLIES LONGEST PATH OF EGRESS = +/-125' RR 106 F FS S S ADJACENT EXISTING TENANT HATCHED AREA NOT IN PROJECT SCOPE M OCCUPANCY (GROCERY STORE) ADJACENT PROPOSED TENANT HATCHED AREA NOT IN PROJECT SCOPE A-2 OCCUPANCY (RESTAURANT) 112'-5 1/2"21'-7 1/2"112'-5 1/2"23'-3"1 HOUR FIRE RATED WALL 1 HOUR RATED DEMISING WALL 1 HOUR RATED DEMISING WALL