HomeMy WebLinkAboutD111.DemoPlanElecrical VEND. VEND.2'-4"
4'-03
4"
DECONSTRUCTION PLAN
DESCRIPTIONDATE
ISSUE
10.20.21 DEMO PERMIT
10.29.21 REVIEW SET
11.05.21 PERMIT SET
REVISONS
DESCRIPTIONMARK DATE DB THE KITTLE BUILDINGBRADLEY COMPANYSUITE 100310 E. 96TH ST. INDIANAPOLIS, IN 462402012.241
BW BW/NP
N0 2' 4' 8' 16'
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR
1ST FLOOR
DECONSTRUCTION
PLAN
D111
ELECTRIC OUTLET(S)
DATA OR
COMMUNICATION
OUTLET
EXISTING TO BE REMOVED EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHT
WALL
DOOR AND FRAME
CEILING GRID AND
TILES, 2'x4'
SUPPLY AIR DIFFUSERS
LIGHT FIXTURE,
FLUORESCENT, 2'x4'
LIGHT FIXTURE, CAN
LIGHT SWITCH
LIGHT FIXTURE,
FLUORESCENT, 2'x2'
WINDOW / SIDELIGHT
CEILING GRID AND
TILES, 2'x2'
LIGHT FIXTURE, TRACK
LIGHT FIXTURE, SCONCE
LIGHT FIXTURE,
PENDANT
EXIT LIGHT
LIGHT FIXTURE,
FLUORESCENT
EXHAUST FAN
EMERGENCY LIGHT
PARTIAL HEIGHT WALLPARTIAL HEIGHT WALL
LEGEND RECYCLING INSTRUCTIONS
SALVAGE FOR
RELOCATION
schottXchange PICKUP
(SEE RECYCLING NOTES)
METALS ONLY RECYCLING BIN:
1. CONTACT WASTE HAULER TO ORDER TRASH DUMPSTER(S) AS
REQUIRED AND (1) "METALS ONLY" RECYCLING BIN FOR THE
DEMOLITION PORTION OF PROJECT ONLY. SIZE OF "METALS ONLY"
BIN IS DETERMINED BY THE AMOUNT OF DEMOLITION (10-40 YARD
CONTAINERS AVAILABLE).
2. DRYWALL MUST BE REMOVED FROM ALL METAL STUDS PRIOR TO
PLACING IN "METALS ONLY" BIN. ANY ADDED LABOR COST WILL BE
COVERED BY METAL CREDITS RECEIVED FROM WASTE HAULER.
3. WASTE HAULER WILL APPLY CREDIT FOR METALS OBTAINED IN
"METALS ONLY" BIN TOWARDS CONTRACTORS OVERALL INVOICE.
4. DATA/DIVERSION REPORTS ARE NOT REQUIRED NOR ANY LEED
PROCESSES OR PAPERWORK.
APPROVED METAL ITEMS:
5. METAL STUDS, DOOR FRAMES, DOOR HARDWARE, CEILING GRID,
LIGHT BOX FIXTURES, METAL CABINETS, METAL PLUMBING FIXTURES,
ELECTRICAL AND DATA WIRING/CONDUIT, HVAC COMPONENTS,
AND ELECTRICAL/DATA/SWITCH BOXES
CARPET RECYCLING:
6. CONTACT KRUSE CARPET RECYCLING TO SCHEDULE PICK UP OF
ALL CARPET BEING REMOVED (BROADLOOM AND CARPET TILE).
COORDINATE REQUIREMENTS AND PICK UP WITH SUSAN SHAFER
(317) 337-1950. DEMOLITION CREW IS NOT RESPONSIBLE FOR
KRUSE SERVICE FEES AND WILL ALSO RECOGNIZE A SAVINGS BY
NO LONGER PAYING HAULING/TIPPING FEES ON CARPET
DISPOSAL WITH WASTE HAULER.
7. KRUSE WILL PROVIDE AN ON-SITE BIN ON DAYS REQUIRED.
DEMOLITION CREW IS TO PLACE CARPET DIRECTLY INTO BIN; DOES
NOT NEED TO BE PALLETIZED. CONTRACTOR IS RESPONSIBLE FOR
KEEPING BINS CLEAN AND DRY AS TO NOT CONTAMINATE
CONTENTS.
8. KRUSE PICK UP AND RECYCLING FEES ARE TO BE PAID THROUGH
SCHOTT DESIGN'S "NO COST ADD PROGRAM". CARPET
MANUFACTURER IS TO PAY $1.00 PER SQUARE YARD FOR CARPET
RECYCLING BY REDUCING PRICE OF CARPET MATERIAL BY $1.00.
FLOORING CONTRACTOR IS RESPONSIBLE FOR DEDUCTING
MATERIAL PRICE AND PAYING $1.00 PER SQUARE YARD TO KRUSE.
CONTACT KATIE OWENS (317) 762-7837 AT SCHOTT DESIGN FOR ANY
QUESTIONS REGARDING THE RECYCLING PROCESSES.
REMOVE EXISTING CABINETRY AND COUNTERTOP.
REMOVE EXISTING SHELVING AND ALL COMPONENTS.
REMOVE EXISTING FLOOR CORE AND INFILL AS REQUIRED TO
MAINTAIN BUILDING CONSTRUCTION TYPE. PREPARE FLOOR FOR
NEW FINISHES AS REQUIRED.
IN AREAS OUTLINED HATCHED, REMOVE CEILING TILES. CEILING
GRID TO REMAIN. REFER TO REFLECTED CEILING PLAN FOR MORE
INFORMATION.
PLAN NOTES
1. REFER TO ALL DECONSTRUCTION NOTES ON TITLE SHEET T111.
2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE
CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT OR
SALVAGED FOR LANDLORD. FOR ALL ITEMS DETERMINED FOR
REMOVAL, REFER TO THE RECYCLING INSTRUCTIONS.
3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN
ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW
FINISHES AS REQUIRED.
4. SALVAGE REMOVED HVAC DIFFUSERS FOR REUSE WHERE
POSSIBLE. SEE REFLECTED CEILING PLAN FOR MORE
INFORMATION. REFER TO RECYCLING INSTRUCTIONS FOR
FIXTURES THAT WILL NOT BE SALVAGED.
5. REFER TO RECYCLING INSTRUCTIONS FOR DOORS THAT WILL NOT
BE SALVAGED.
6. REMOVE ALL EXISTING 2X4 LIGHTING FIXTURES THROUGHOUT,
UNLESS NOTED OTHERWISE. SEE REFLECTED CEILING PLAN FOR
MORE INFORMATION ON NEW LIGHTING.
GENERAL NOTES
AREA NOT IN CONTRACT
AREA OF WORK
12/02/21