HomeMy WebLinkAboutE111.ElectricalElecrical VEND. VEND.U.C.REFRIGENTRY
101
COATS
102
CONFERENCE
103
CONF
104
OFFICE
105
OFFICE
106
OFFICE
107
OFFICE
108
OFFICE
109
OFFICE
110
OFFICE
112
OFFICE
113
OFFICE
114
IT
115
MEET
116
OFFICE
117
OFFICE
118
OFFICE
119
OFFICE
120
OFFICE
121
OFFICE
124
OFFICE
123
OFFICE
125
OFFICE
126
OFFICE
127
OFFICE
128
OFFICE
129
OFFICE
130
OFFICE
131
WELLNESS
132
PH. RM.
133
PH. RM.
134
OPEN OFFICE
135
COPY
136
CAFE
137
OPEN OFFICE
138
COPY
139
DW
REFRIGBYTENANTPANTRY
140
OFFICE
111TVTV TV
TV
TV
TVTV
TV6x66x6BREAK
122 TVTVDED +60"
+60"
+60"
+60"+60"
+60"+60"
+60"+60"+60"DED +60"+60"+60"+60"+
6
0
"
+
6
0
"DED+44"+60"+60"+44"
+44"+60"+60"+42"
+42"+44"+44"J J
DED +44"GFCIGFCI
GFCI
GFCI
J J J
+60"+60"TV ICEDWDESCRIPTIONDATE
ISSUE
10.20.21 DEMO PERMIT
10.29.21 REVIEW SET
11.05.21 PERMIT SET
REVISONS
DESCRIPTIONMARK DATE DB THE KITTLE BUILDINGBRADLEY COMPANYSUITE 100310 E. 96TH ST. INDIANAPOLIS, IN 462402012.241
BW BW/NP
N0 2' 4' 8' 16'
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR
1ST FLOORELECTRICAL PLAN
E111ELECTRICAL PLAN
LEGEND
DED
POWER OUTLET, DUPLEX
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
POWER OUTLET, DUPLEX
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
BOX, BLANK COVER PLATE
BOX, OPEN
BOX, BLANK COVER PLATE
BOX, OPEN
POWER AND DATA POLE
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
JUNCTION BOX AND
DATA, FLUSH MOUNTED
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DEDICATED CIRCUIT
DATA/COMMUNICATION
OUTLET (PROVIDE BOX
AND PULL STRING ONLY)
DATA/COMMUNICATION
OUTLET
GFCI GROUND FAULT CIRCUIT
INTERRUPT OUTLET
HEIGHT OF ELECTRICAL
OR DATA DEVICE
CEILING MOUNTED
JUNCTION BOX
CEILING MOUNTED
JUNCTION BOX
J
B
O
J
+42"
PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER
(CARD READER BY TENANT). COORDINATE WITH TENANT'S
SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE
DETAILS.
COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
DEDICATED RECEPTACLE AS REQUIRED.
PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE
SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S
FURNITURE VENDOR.
PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET
INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT
24" A.F.F.
PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED
TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT
LOCATION WITH TENANT. PROVIDE ARLINGTON'S TVBU810
RECESSED TV BOX (OR EQUAL) AT WALL MOUNTED TELEVISION.
PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE
FOR ELECTRICAL AND DATA. COORDINATE WITH TENANTS
FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU
DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO
ORDERING.
PROVIDE DIRECT HDMI/VGA CONDUIT CONNECTION FROM
FLOOR CORE POKE THRU DEVICE TO WALL MOUNTED
MONITOR(S).
PROVIDE POWER AT THIS LOCATION FOR TENANT'S DISHWASHER.
CONFIRM ALL IT REQUIREMENTS WITH TENANT.
PROVIDE ALL REQUIREMENTS FOR TENANT PROVIDE PLOTTER.
CONFIRM WITH TENANT.
COORINATE POWER FOR SIGNAGE AT FEATURE WALL WITH
TENANT.
PLAN NOTES
1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL
NEW DEVICES AND FACE PLATES TO BE WHITE. REPLACE EXISTING
WITH NEW AS REQUIRED.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. CONTRACTOR TO PROVIDE GFCI OUTLET FOR WATER HEATER AND
AUTOMATIC SHUTOFF VALVES AS REQUIRED.
5. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
GENERAL NOTES
PROVIDE JUNCTION BOX
ABOVE CEILING FOR
POWER POLE
CONNECTION. POWER
POLE BY OTHERS.
AREA NOT IN CONTRACT
AREA OF WORK
12/02/21