HomeMy WebLinkAboutL100.LifeSafetyPump Room
Storage
Elevator
Elecrical
STG
IDF
VEND. VEND.ENTRY
101
COATS
102
x
CONFERENCE
103
28'-0"16'-6"
x
CONF
104
14'-5"16'-6"
x
OFFICE
105
11'-9"11'-6"x
OFFICE
106
14'-8"11'-6" x
OFFICE
107
14'-8"11'-6" x
OFFICE
108
14'-8"11'-6" x
OFFICE
109
9'-8"11'-6" x
OFFICE
110
9'-7"11'-6"
x
OFFICE
112
14'-8"17'-9"
x
OFFICE
113
8'-3"10'-0"x
OFFICE
114
9'-3"10'-0"
x
IT
115
6'-0"9'-11" x
MEET
116
8'-2"9'-11"
x
OFFICE
117
12'-5"12'-0"x
OFFICE
118
10'-0"12'-0"x
OFFICE
119
13'-2"12'-0"
x
OFFICE
120
22'-9"10'-0"
x
OFFICE
121
14'-6"10'-5"
x
OFFICE
124
14'-8"16'-8"
x
OFFICE
123
14'-8"13'-4"
x
OFFICE
125
10'-11"15'-1"x
OFFICE
126
10'-2"15'-0"x
OFFICE
127
9'-8"15'-0"x
OFFICE
128
9'-8"15'-1"x
OFFICE
129
9'-8"15'-1"x
OFFICE
130
9'-8"15'-1"x
OFFICE
131
9'-8"15'-1"WELLNESS
132
86 SF
x
PH. RM.
133
6'-10"7'-7"
x
PH. RM.
134
6'-10"8'-7"
OPEN OFFICE
135
COPY
136
CAFE
137
OPEN OFFICE
138
COPY
139
DW
PANTRY
140
x
OFFICE
111
21'-5"11'-5"6x66x6BREAK
122
204 SF
FEFEFEFENLEL
NLELNLEL
NLEL
NLEL
NLEL NLELNLELNLEL
NLEL
NLEL
NLEL ICEDWDESCRIPTIONDATE
ISSUE
10.20.21 DEMO PERMIT
10.29.21 REVIEW SET
11.05.21 PERMIT SET
REVISONS
DESCRIPTIONMARK DATE DB THE KITTLE BUILDINGBRADLEY COMPANYSUITE 100310 E. 96TH ST. INDIANAPOLIS, IN 462402012.241
BW BW/NP
N
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR
1ST FLOORLIFE SAFETY PLAN
L100LIFE SAFETY PLANAREA NOT IN CONTRACT
AREA OF WORK
LIFE SAFETY NOTES
GENERAL NOTES
SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT-OUT OFFICE SPACE
TOTAL BUILDING AREA
TOTAL PROJECT AREA
CHANGE OF OCCUPANCY CLASS?
OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD
NO
OCCUPANCY CLASSIFICATION B(USINESS)
GEN. OFFICE SF 100
SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES 0
TOTAL AREA ON THE FLOOR
SF
SF/FLOOR X STORIES SF
SF
23,056 SF
ACCESSORY AREA EXCEEDS 10% NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED)
EXISTING FIRE RATED WALLS TO REMAIN AT EXIT DISCHARGE
LOCATIONS
=
TOTAL OCCUPANTS IN PROJECT AREA 96
CODE SUMMARY
PREVIOUS USE OF SPACE B(USINESS)
ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE A121)
BUILT BEFORE 1978? NO
9,504
9,504
96
BUILDING CONSTRUCTION TYPE I-B
L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND
CONSTRUCTION DETAILS.
L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT
SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS
AS REQUIRED TO MEET ALL LOCAL AND STATE CODES.
L3. SQUARE FOOTAGES NOTED IN CODE SUMMARY CHART ARE NOT
REFLECTIVE OF USABLE/RENTABLE SQUARE FOOTAGE AS
CALCULATED BY METHODS SUCH AS BOMA STANDARDS.
OCCUPANCY CALCULATIONS & TOTALS ARE CALCULATED BASED
ON INTERNATIONAL BUILDING CODE NOT ACTUAL HEAD COUNTS.
CONTACT SDI FOR ADDITIONAL INFORMATION AS NECESSARY.
EXISTING ELECTRICAL PANEL LOCATION
EXISTING EXIT
EP
EX
LEGEND
FIRE EXTINGUISHER
EXIT SIGN
FE
NIGHT LIGHT/EMERGENCY LIGHTING
NLEL
FE
TRAVEL DISTANCE
NUMBER OF EXITS REQUIRED: 2 PROVIDED: 4
- LED EDGE LIT
0 8' 16'4'
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
EX
EX
EX
EX
BUSINESS
TRAVEL DISTANCE: 154'
TRAVEL DISTANCE: 141'
BUSINESS
BUSINESS/ASSEMBLYBUSINESS/ASSEMBLY
BUSINESS/ASSEMBLY
BUSINESS
BUSINESS
BUSINESS
VARIES 4 87,306
EP
12/02/21