Loading...
HomeMy WebLinkAboutA111.ArchFloorWALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF ACOUSTICAL SEALANT. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT TYPICAL WALL TYPE METAL STUD EXISTING WINDOW MULLION EQUAL Elecrical VEND. VEND.U.C.REFRIGENTRY 101 COATS 102 CONFERENCE 103 CONF 104 OFFICE 105 OFFICE 106 OFFICE 107 OFFICE 108 OFFICE 109 OFFICE 110 OFFICE 112 OFFICE 113 OFFICE 114 IT 115 MEET 116 OFFICE 117 OFFICE 118 OFFICE 119 OFFICE 120 OFFICE 121 OFFICE 124 OFFICE 123 OFFICE 125 OFFICE 126 OFFICE 127 OFFICE 128 OFFICE 129 OFFICE 130 OFFICE 131 WELLNESS 132 PH. RM. 133 PH. RM. 134 OPEN OFFICE 135 COPY 136 CAFE 137 OPEN OFFICE 138 COPY 139 DW REFRIGBYTENANTPANTRY 140 OFFICE 111 BREAK 122 15'-412"10'-01 4" CL 17'-034"8"10'-4"4'-0" HOLD14'-101 2" 6'-4" 4'-03 4"23'-1" ALIGN7'-11"EQ.EQ.14'-834"EQ.12'-4"ALIGNEQ. 3'-1" 4'-21 2"9'-1014"1'-8" 1'-2" 13'-11 2" 28'-4"16'-934"6'-714"±135° TYP. CL CL 10'-4"8'-63 4"FEFEFEFE22'-6" V.I.F. 14'-0" V.I.F. 20'-0" V.I.F. 135 °9'-7"ICEDWDESCRIPTIONDATE ISSUE 10.20.21 DEMO PERMIT 10.29.21 REVIEW SET 11.05.21 PERMIT SET REVISONS DESCRIPTIONMARK DATE DB THE KITTLE BUILDINGBRADLEY COMPANYSUITE 100310 E. 96TH ST. INDIANAPOLIS, IN 462402012.241 BW BW/NP N0 2' 4' 8' 16' THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR 1ST FLOOR ARCHITECTURAL FLOOR PLAN A111 ARCHITECTURAL PLAN AREA NOT IN CONTRACT AREA OF WORK WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHTWINDOW / SIDELIGHT LEGEND W1 WALL WITH INSULATION 358 " METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS BATT SOUND INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W2 PARTIAL HEIGHT WALL 358 " METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; WALL TO EXTEND TO 3'-4" AFF; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. PLAN NOTES GENERAL NOTES NOT TO SCALE WALL AT MULLION DETAIL A111 1 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'x8'x3 4", PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. NEW FIRE EXTINGUISHER AND SEMI-RECESSED CABINET (PAINTED TO MATCH ADJACENT WALL COLOR) TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. EXISTING FIRE EXTINGUISHER TO REMAIN IF IN PROPER WORKING ORDER. CONTRACTOR TO CONFIRM THAT EXISTING FIRE EXTINGUISHER IS INSTALLED ACCORDING TO NFPA 10. REPAINT RECESSED CABINET TO MATCH ADJACENT WALL COLOR. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W1". IF NOT, ALTER EXISTING WALL AS REQUIRED TO MATCH "W1". AT THIS LOCATION, PROVIDE (5) 18” DEEP ADJUSTABLE BLACK MELAMINE SHELVES ON HEAVY DUTY KV BRACKETS AND STANDARDS. AT THIS LOCATION, PROVIDE 18” DEEP ROUGH SAWN WOOD COUNTER AT 36” AFF. SUPPORT COUNTER AS REQUIRED WITH RAKKS EH-1818-FM FLUSH MOUNTED SUPPORT BRACKETS ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL SUPPORTS. COUNTER TO BE ENTIRE WIDTH OF ROOM AS SHOWN; VERIFY DIMENSIONS IN FIELD. AT THIS LOCATION, PROVIDE 3’-3” WIDE X 10’-0” LONG CAMBRIA QUARTZ (QZ_) COUNTERTOP AT 3'-4" AFF WITH WATERFALL EDGE ON WEST END OF ISLAND. COUNTERTOP TO BE SUPPORTED AS REQUIRED WITH CENTERLINE BRACKET’S FRONT MOUNTING PLUS BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL SUPPORTS. MILLWORKER + GC TO COORDINATE CLOSELY WITH CAMBRIA QUARTZ TO ENSURE TIMELY AND ACCURATE INSTALLATION OF ISLAND. PROVIDE 24"H CLERESTORY WINDOWS WITH 38" BUTT GLAZED TEMPERED GLASS WITH TIMELY FRAMES (COLOR: BLACK), CENTERED ON WALL. DESIGN INTENT IS FOR TOP OF WINDOW FRAME TO ALIGN WITH TOP OF DOOR FRAMES. LENGTHS VARY, SEE PLAN + VERIFY ALL DIMENSIONS IN FIELD. CONFIRM SHELVING IS IN WORKING CONDITION WITH TENANT. PROVIDE SEPARATE PRICE FOR NEW SHELVING ACCORDING TO TENANT REQUIREMENTS. _______________________________________________________________ PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. PROVIDE INSULATION ON ALL NEW AND EXISTING PIPING. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. CONTRACTOR TO INSTALL AUTOMATIC SHUTOFF VALVES AND BACK FLOW PREVENTERS AS REQUIRED. PROVIDE WATER LINE WITH BACKFLOW PREVENTER FOR COFFEE, ICE MAKER, AND/OR REFRIGERATOR. CONFIRM LOCATION WITH TENANT. PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT-PROVIDED ADA HEIGHT DISHWASHER AT THIS LOCATION. GC TO PROVIDE TENANT WITH CUT SHEET FOR APPROVAL PRIOR TO ORDERING. 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 3. PROVIDE INSULATION ON ALL NEW AND EXISTING PLUMBING PIPING AND BACK FLOW PREVENTERS ON ALL WATER LINES AS REQUIRED. 4. PROVIDE ALTERNATE PRICE FOR NEW BLINDS THROUGHOUT: MECHOSHADE CLASSIC MECHO/5 MANUAL ROLLER-SHADES (OR EQUAL), COLOR TBD. TYP. A111 1 W2 A211 9 A211 8 A211 10 A211 7 A211 6 A211 2 A211 3 A211 4 A211 4 A211 5 W2 12/02/21