HomeMy WebLinkAboutA121. ReflectedCeilingElecrical VEND. VEND.SNSNSNSNSNSN SNSNSNSNSNSNSNSNSNSNSNSNSNSN SNSNSNSNSNSNSNSNSNSNSNSNSNS N4
SN4 SN4NLEL
NLELNLEL
NLEL
NLEL
NLEL
NLELNLELNLEL
NLEL
NLEL
NLEL A
A
A
A
B B B
C
C
C
C SNESN4
DESCRIPTIONDATE
ISSUE
10.20.21 DEMO PERMIT
10.29.21 REVIEW SET
11.05.21 PERMIT SET
REVISONS
DESCRIPTIONMARK DATE DB THE KITTLE BUILDINGBRADLEY COMPANYSUITE 100310 E. 96TH ST. INDIANAPOLIS, IN 462402012.241
BW BW/NP
N0 2' 4' 8' 16'
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR
1ST FLOOR
REFLECTED
CEILING PLAN
A121REFLECTED CEILING PLAN
A121
1
MECHANICAL DIFFUSER RELOCATION
A121
1
*REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
RELOCATE DIFFUSERS &
FLEXDUCT IF REQUIRED
EXISTING VAV BOXES OR
HEAT PUMP AND MAIN SUPPLY
DUCTS TO REMAIN
VAV /
HEAT PUMP
CONTROL OPEN OFFICE AREA LIGHTING WITH 4-WAY SWITCH AT
THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED.
PAINT EXISTING GRID IN THIS LOCATION. PAINT COLOR: TBD.
PLAN NOTES
SWITCH, PROJECTOR
SCREEN
LIGHT CIRCUIT
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
NP
ND
N
N3
P
D
3
COMPASS CEL EDGE LIT
EXIT LIGHT FIXTURE
LIGHT FIXTURE,
PENDANT, $800
MATERIAL ALLOWANCE
RECESSED LIGHT
FIXTURE
LIGHT FIXTURE, 2'x2',
COLUMBIA LIGHTING, CCL
LED
LIGHT FIXTURE, 2'x4',
COLUMBIA LIGHTING, CCL
LED
RELOCATED DIFFUSER,
LAY-IN, 4"x4'
RELOCATED DIFFUSER,
LAY-IN, 1'x4'
RELOCATED DIFFUSER,
LAY-IN, 2'x2'
CEILING GRID,
SUSPENDED, 2'x2'
CEILING GRID,
SUSPENDED, 2'x4'
NEW OR RELOCATED EXISTING TO REMAIN
SWITCH, PROJECTOR
SCREEN
LIGHT CIRCUIT
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
CEILING GRID,
SUSPENDED, 2'x2'
CEILING GRID,
SUSPENDED, 2'x4'
DIFFUSER,
LAY-IN, 4"x4'
DIFFUSER,
LAY-IN, 1'x4'
DIFFUSER,
LAY-IN, 2'x2'
CEILING GRID,
SUSPENDED, 4'x4' TEES TO
COMPLETE GRID
CEILING GRID,
SUSPENDED, 4'x4'
GYPSUM BOARD CEILING
LEGEND
EMERGENCY LIGHT FIXTURE
EXHAUST FAN, 2'x2' EXHAUST FAN, 2'x2'
GYPSUM BOARD CEILING
SWITCH, GARBAGE
DISPOSAL (ABOVE
COUNTERTOP)
NG G SWITCH, GARBAGE
DISPOSAL
NEW UPGRADED CEILING
TILES IN THIS LOCATION TO
BE; FACT CEILING TILES.
EXACT PATTERN AND
COLOR, TBD. EXISTING
GRID TO REMAIN.
SWITCH, EXHAUST FANNE E SWITCH, EXHAUST FAN
1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED.
EXISTING GRID IS 2x2 AT 8'-4" A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN
TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED
TILES WITH NEW TO MATCH EXISTING.
2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM
DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE
CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE
UNIFORM LOOK.
3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN
SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI
OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT
IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1,
CONTRACTOR MUST NOTIFY SDI.
5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO
UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A
ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED.
6. NEW DEVICES AND FACE PLATES TO BE WHITE. REPLACE EXISTING AS
REQUIRED. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO
ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN
ADJACENT ON PLAN.
7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING
ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED
SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
8. PROVIDE ALTERNATE PRICE FOR DIMMER CONTROLS IN ALL
LOCATIONS. CONTRACTOR IS TO VERIFY THAT PROJECT CRITERIA
MEET INDIANA ASHRAE 90.1 ENERGY CODES. DESIGN INTENT IS TO BE
AT LEAST 35-40 FOOT CANDLES PER SQUARE FOOT AVERAGE AT 30”
A.F.F. CONTRACTOR TO PROVIDE PHOTOMETRIC STUDY FROM
LIGHTING MANUFACTURER. PROVIDE ENERGY MANAGEMENT
CONTROLS, SUCH AS SENSOR CONTROLS (MICROPHONIC, PIR OR
INFRARED AS USAGE DICTATES) AND/OR RELAY TIME CLOCKS AS
REQUIRED BY THE CODE.
GENERAL NOTES
1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING
H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE
SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS
BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY
APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT
ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
MECHANICAL NOTES
AREA NOT IN CONTRACT
AREA OF WORK
LIGHT FIXTURE,
PENDANT, $800
MATERIAL ALLOWANCE
LIGHT FIXTURE,
PENDANT, $1,500
MATERIAL ALLOWANCE
EL
A
B
C
12/02/21