Loading...
HomeMy WebLinkAboutA121. ReflectedCeilingElecrical VEND. VEND.SNSNSNSNSNSN SNSNSNSNSNSNSNSNSNSNSNSNSNSN SNSNSNSNSNSNSNSNSNSNSNSNSNS N4 SN4 SN4NLEL NLELNLEL NLEL NLEL NLEL NLELNLELNLEL NLEL NLEL NLEL A A A A B B B C C C C SNESN4 DESCRIPTIONDATE ISSUE 10.20.21 DEMO PERMIT 10.29.21 REVIEW SET 11.05.21 PERMIT SET REVISONS DESCRIPTIONMARK DATE DB THE KITTLE BUILDINGBRADLEY COMPANYSUITE 100310 E. 96TH ST. INDIANAPOLIS, IN 462402012.241 BW BW/NP N0 2' 4' 8' 16' THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR 1ST FLOOR REFLECTED CEILING PLAN A121REFLECTED CEILING PLAN A121 1 MECHANICAL DIFFUSER RELOCATION A121 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN VAV / HEAT PUMP CONTROL OPEN OFFICE AREA LIGHTING WITH 4-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. PAINT EXISTING GRID IN THIS LOCATION. PAINT COLOR: TBD. PLAN NOTES SWITCH, PROJECTOR SCREEN LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH NP ND N N3 P D 3 COMPASS CEL EDGE LIT EXIT LIGHT FIXTURE LIGHT FIXTURE, PENDANT, $800 MATERIAL ALLOWANCE RECESSED LIGHT FIXTURE LIGHT FIXTURE, 2'x2', COLUMBIA LIGHTING, CCL LED LIGHT FIXTURE, 2'x4', COLUMBIA LIGHTING, CCL LED RELOCATED DIFFUSER, LAY-IN, 4"x4' RELOCATED DIFFUSER, LAY-IN, 1'x4' RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x2' CEILING GRID, SUSPENDED, 2'x4' NEW OR RELOCATED EXISTING TO REMAIN SWITCH, PROJECTOR SCREEN LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH CEILING GRID, SUSPENDED, 2'x2' CEILING GRID, SUSPENDED, 2'x4' DIFFUSER, LAY-IN, 4"x4' DIFFUSER, LAY-IN, 1'x4' DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 4'x4' TEES TO COMPLETE GRID CEILING GRID, SUSPENDED, 4'x4' GYPSUM BOARD CEILING LEGEND EMERGENCY LIGHT FIXTURE EXHAUST FAN, 2'x2' EXHAUST FAN, 2'x2' GYPSUM BOARD CEILING SWITCH, GARBAGE DISPOSAL (ABOVE COUNTERTOP) NG G SWITCH, GARBAGE DISPOSAL NEW UPGRADED CEILING TILES IN THIS LOCATION TO BE; FACT CEILING TILES. EXACT PATTERN AND COLOR, TBD. EXISTING GRID TO REMAIN. SWITCH, EXHAUST FANNE E SWITCH, EXHAUST FAN 1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS 2x2 AT 8'-4" A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. 5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 6. NEW DEVICES AND FACE PLATES TO BE WHITE. REPLACE EXISTING AS REQUIRED. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS.  ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 8. PROVIDE ALTERNATE PRICE FOR DIMMER CONTROLS IN ALL LOCATIONS. CONTRACTOR IS TO VERIFY THAT PROJECT CRITERIA MEET INDIANA ASHRAE 90.1 ENERGY CODES. DESIGN INTENT IS TO BE AT LEAST 35-40 FOOT CANDLES PER SQUARE FOOT AVERAGE AT 30” A.F.F. CONTRACTOR TO PROVIDE PHOTOMETRIC STUDY FROM LIGHTING MANUFACTURER. PROVIDE ENERGY MANAGEMENT CONTROLS, SUCH AS SENSOR CONTROLS (MICROPHONIC, PIR OR INFRARED AS USAGE DICTATES) AND/OR RELAY TIME CLOCKS AS REQUIRED BY THE CODE. GENERAL NOTES 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED.  ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED;  MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. MECHANICAL NOTES AREA NOT IN CONTRACT AREA OF WORK LIGHT FIXTURE, PENDANT, $800 MATERIAL ALLOWANCE LIGHT FIXTURE, PENDANT, $1,500 MATERIAL ALLOWANCE EL A B C 12/02/21