Loading...
HomeMy WebLinkAboutA000.7MIN. 136 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF \A1;3'-0" 4:12 4:12 \A1;20'-0" OPT. POT VENTS \A1;6'-0" \A1;5'-0" \A1;6'-0" \A1;1'-0"\PTYP.HR3S-IN1HR3S-IN1ROOF AREA "B"SQ FTG144AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.190.240.4246.5610AT EAVE0.290.240.4953.4407.00TOTAL (MIN)0.480.480.91100.003 HIGH -RIDGE VENT0.190.240.3843.55003.00AT EAVE0.290.240.4956.4507.00TOTAL (MIN)0.480.480.86100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEROOF AREA "A"SQ FTG2396AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY3.193.994.2450.00100AT EAVE4.793.994.2450.00061.00TOTAL (MIN)7.997.998.47100.003 HIGH -RIDGE VENT3.193.993.8847.770031.00AT EAVE4.793.994.2452.23061.00TOTAL (MIN)7.997.998.11100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEMIN. 12 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D"6:126:1210:1210:1210:1210:128:128:1210:128:1210:126.5:126.5:1210:1210:12\A1;1'-0"\PTYP.8:12MIN. 177 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "C"6:12\pxqr;OPT. GUTTER AND DOWNSPOUTSPROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION8:128:128:12"A"2396ROOF AREA:SQ. FT."B"144ROOF AREA:SQ. FT.A4.01 ROOF PLANMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc. PRODUCT MANAGER----VERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPE Single Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Truman 1702.300Home for * Market Home *, 7231-017002902 Trailblazer Court, Carmel, IN 46032ROOF PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER)MIN. 177 SQ. IN. OF VENTILATIONREQUIRED AT EAVE FOR ROOF "C"ROOF AREA: "A"ROOF AREA: "B"MIN. 12 SQ. IN. OF VENTILATIONREQUIRED AT EAVE FOR ROOF "D"2396 SQ. FT.144 SQ. FT.OPT. GUTTER ANDDOWNSPOUTSPROVIDE ADEQUATE OPENINGFOR AIR MOVEMENT BETWEENATTIC SPACES TO SUPPORTREQUIRED VENTILATIONOPT. POTVENTSTYP.10:12 10:12 10:12 10:12 10:12 10:12 10:12 10:128:128:128:12 8:12 8:12 6.5:126.5:126:128:128:126:126:121' - 0"20' - 0"5' - 0"6' - 0"12/02/21