)R=62 4. 92L=147.75D =13.55N0°31'20"W 909.09' (D) C101
JOB#: BWF.001SITE PLANDATE: 05/19/21DRAWN BY: RCW(317) 251-1738 (FAX) 251-1923INDIANAPOLIS, INDIANA 462206555 CARROLLTON AVENUEwww.rw-engineering.comCIVIL ENGINEERS - LAND SURVEYORS - DEVELOPMENT CONSULTANTS12430 CLARK STREETBE WELL FAMILY CARECARMEL, INDIANA-
W
DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL
BE RESTORED/REPAIRED TO THE SATISFACTION
OF THE CITY AT THE COMPLETION OF THE
PROJECT. THE CONTRACTOR IS ENCOURAGED
TO INSPECT THE RIGHT-OF-WAY WITH THE CITY
PRIOR TO THE START OF THE CONSTRUCTION
TO DOCUMENT THE EXISTING CONDITION OF THE
RIGHT-OF-WAY.
BUILDING FOOTPRINT AREA = 9,276 SF
SITE AREA = 2.25 AC+/-
ZONING = M-3
FRONT BLDG. SETBACK AND BUFFER YARD = 10 FT
SOUTH SIDE BLDG. SETBACK = 10 FT
SOUTH SIDE BUFFER YARD = 5 FEET
NORTH SIDE BLDG. SETBACK = 50 FT
NORTH SIDE BUFFER YARD = 30 FT
REAR SETBACK = 20 FT
% LOT COVERAGE = 0.76 / 2.25 = 34%
ON-SITE PARKING REQUIRED:
1 SPACE PER 250 SF OF FLOOR AREA
FLOOR AREA = 9,276 / 250 = 38 SPACES REQ'D
ON-SITE PARKING PROVIDED:
STANDARD SPACES = 43
ACCESSIBLE SPACES = 2
TOTAL: 45 SPACES PROVIDED
DEVELOPMENT SUMMARY