HomeMy WebLinkAboutA000.7OPT. GUTTER AND DOWNSPOUTSMIN. 153 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF
\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.
PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION
\pxi-3,l4,t4;OPT. POT VENTSPROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION
\A1;22'-0"
\A1;6'-0"
\A1;4'-6{\H0.75x;\S1#2;}"
\A1;2'-11"
\A1;6'-1"
\A1;2'-11"
\A1;1'-2"
\A1;1'-0"
\A1;5'-0"
\pxi-3,l4,t4;OPT. GUTTER AND DOWNSPOUTS
4:12
4:12
8:12
8:12
10:12
10:12
10:1210:12
10:1210:12
"A"
2122ROOF AREA:
SQ. FT.
10:12
10:12
"B"
415ROOF AREA:
SQ. FT.Heartland 2HHeartland 2HATTIC VENT SCHEDULEVENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATIONROOF AREA "A"SQ FTG2122AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY2.833.543.3947.4780AT EAVE4.243.543.7552.53054.00TOTAL (MIN)7.077.077.14100.003 HIGH -RIDGE VENT2.833.543.5048.280028.00AT EAVE4.243.543.7551.72054.00TOTAL (MIN)7.077.077.25100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEROOF AREA "B"SQ FTG415AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.550.690.8548.4120AT EAVE0.830.690.9051.59013.00TOTAL (MIN)1.381.381.75100.003 HIGH -RIDGE VENT0.550.690.7545.38006.00AT EAVE0.830.690.9054.62013.00TOTAL (MIN)1.381.381.65100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE3.5:1210:128:12A4.01 ROOF PLANMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2019 PulteGroup, Inc.
PRODUCT MANAGERRICK STARKEYVERSION RELEASEDATE:05/10/2019
PROJECT TYPE
Single Family
SHEET
PLAN NAME
SPECIFICATION LEVEL
NPC CHILD NUMBER
----
Deer Valley
2107.300Home for * Market Home *, 7231-018002880 Trailblazer Court, Carmel, IN 46032ROOF PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER)
12/06/21