Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
I48535885.18_Estates_at_Towne_Meadow
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). October 27,2021 Liu, Xuegang Pages or sheets covered by this seal: I48535885 thru I48535913 My license renewal date for the state of Indiana is July 31, 2022. 18_Estates_at_Towne_Meadow 18 Estates at Towne Meadow IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss GE01 Truss Type GABLE Qty 1 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535885 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:29:45 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-BrRZ3we7nTRmYNJBwuqU7XdGOAPYfgOOcMLwOvyPTia Scale = 1:59.9 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 25 24 23 22 21 20 19 18 17 16 15 14 26 27 2x4 2x4 4x6 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 20-11-0 20-11-0 -1-0-0 1-0-0 10-5-8 10-5-8 20-11-0 10-5-8 21-11-0 1-0-0 1-2-09-0-21-2-09.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.08 0.04 0.16 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 309 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-19 REACTIONS.All bearings 20-11-0. (lb) - Max Horz 25=-109(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 25, 14, 21, 24, 17, 15 Max Grav All reactions 250 lb or less at joint(s) 25, 14, 19, 20, 21, 23, 24, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 7-5-8, Corner(3R) 7-5-8 to 13-5-8, Exterior(2N) 13-5-8 to 18-11-0, Corner(3E) 18-11-0 to 21-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 25, 14, 21, 24, 17, 15. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss GE02 Truss Type GABLE Qty 1 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535886 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:29:47 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-7EYJUbgNJ5iUnhTa1JsyDyicL_4u7agh4gq0TnyPTiY Scale = 1:89.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 12 3 45 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 2223 24 25 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 2x4 2x4 3x6 3x6 3x6 2x4 2x4 3x6 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 37-11-0 37-11-0 -1-0-0 1-0-0 16-4-8 16-4-8 21-6-8 5-2-0 37-11-0 16-4-8 38-11-0 1-0-0 1-1-012-0-01-1-012-0-08.00 12 Plate Offsets (X,Y)-- [2:0-2-15,0-0-8], [12:0-4-8,0-2-8], [15:0-4-4,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.11 0.05 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 25 25 26 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 772 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 *Except* 15-35,14-36,13-37,11-39,16-33: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 12-15. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 15-35, 14-36, 13-37, 11-39, 10-40, 9-41, 16-33, 17-32 REACTIONS.All bearings 37-11-0. (lb) - Max Horz 47=-141(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 47, 26, 40, 42, 43, 44, 46, 32, 31, 30, 29, 27 Max Grav All reactions 250 lb or less at joint(s) 47, 26, 35, 36, 37, 39, 40, 41, 42, 43, 44, 45, 46, 33, 32, 31, 30, 29, 28, 27 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 13-4-8, Corner(3R) 13-4-8 to 24-6-8, Exterior(2N) 24-6-8 to 35-11-0, Corner(3E) 35-11-0 to 38-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 47, 26, 40, 42, 43, 44, 46, 32, 31, 30, 29, 27. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss GE03 Truss Type GABLE Qty 1 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535887 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:29:49 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-4cg3vHhdriyB1_dy9kvQINnxbomHbUA_X_J7YgyPTiW Scale = 1:88.6 Sheet FrontFull Sheathing1 Ply 7/16OSB8 12 3 45 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 2223 24 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 2x4 3x4 3x6 3x6 3x6 2x4 2x4 3x6 5x6 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 37-7-8 37-7-8 -1-0-0 1-0-0 16-4-8 16-4-8 21-6-8 5-2-0 37-7-8 16-1-0 1-1-012-0-01-3-512-0-08.00 12 Plate Offsets (X,Y)-- [12:0-4-8,0-2-8], [15:0-4-4,0-2-4], [33:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.05 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 0.00 (loc) 1 1 25 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 769 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 24-25: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 15-33,14-34,13-35,11-37,16-32: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 12-15. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 15-33, 14-34, 13-35, 11-37, 10-38, 9-39, 16-32, 17-31 REACTIONS.All bearings 37-7-8. (lb) - Max Horz 45=139(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 45, 25, 38, 39, 40, 41, 42, 44, 32, 31, 30, 29, 28, 26 Max Grav All reactions 250 lb or less at joint(s) 45, 25, 33, 34, 35, 37, 38, 39, 40, 41, 42, 43, 44, 32, 31, 30, 29, 28, 27, 26 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 13-4-8, Corner(3R) 13-4-8 to 24-6-8, Exterior(2N) 24-6-8 to 34-6-4, Corner(3E) 34-6-4 to 37-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 45, 25, 38, 39, 40, 41, 42, 44, 32, 31, 30, 29, 28, 26. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss GE04 Truss Type GABLE Qty 1 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535888 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:29:51 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-0?oqKzjuNJCvGInLG9xuNotItbSB3P4H?IoEcZyPTiU Scale = 1:35.5 Sheet FrontFull Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 2x4 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 11-11-0 11-11-0 -1-0-0 1-0-0 5-11-8 5-11-8 11-11-0 5-11-8 12-11-0 1-0-0 1-2-05-7-101-2-09.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.08 0.02 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 9 9 10 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 130 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 11-11-0. (lb) - Max Horz 16=72(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 16, 10, 14, 15, 12, 11 Max Grav All reactions 250 lb or less at joint(s) 16, 10, 13, 14, 15, 12, 11 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 1-11-8, Exterior(2N) 1-11-8 to 2-11-8, Corner(3R) 2-11-8 to 8-11-8, Exterior(2N) 8-11-8 to 9-11-0, Corner(3E) 9-11-0 to 12-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10, 14, 15, 12, 11. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss GE05 Truss Type GABLE Qty 1 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535889 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:29:53 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-yOwalfk8vwSdVcwjOZzMSCyegP7BXIIaScHLhRyPTiS Scale = 1:81.1 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1920 21 3938 37 36 35 34 33 32 31 30 29 28 27 26 25 24 2322 40 41 3x4 4x6 3x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 29-9-0 29-9-0 -1-0-0 1-0-0 14-10-8 14-10-8 29-9-0 14-10-8 30-9-0 1-0-0 1-2-012-3-141-2-09.00 12 Plate Offsets (X,Y)-- [2:0-3-1,0-0-8], [20:0-3-1,0-0-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.12 0.05 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 21 21 22 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 568 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 *Except* 11-30,10-32,12-29: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 11-30, 10-32, 9-33, 12-29, 13-28 REACTIONS.All bearings 29-9-0. (lb) - Max Horz 39=146(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 33, 34, 35, 36, 28, 27, 26, 25, 24, 22 except 39=-120(LC 6), 38=-116(LC 7), 23=-102(LC 11) Max Grav All reactions 250 lb or less at joint(s) 39, 30, 32, 33, 34, 35, 36, 37, 38, 29, 28, 27, 26, 25, 24, 23, 22 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 11-10-8, Corner(3R) 11-10-8 to 17-10-8, Exterior(2N) 17-10-8 to 27-9-0, Corner(3E) 27-9-0 to 30-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 33, 34, 35, 36, 28, 27, 26, 25, 24, 22 except (jt=lb) 39=120, 38=116, 23=102. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss GE06 Truss Type GABLE Qty 1 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535890 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:29:54 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:osuczORs1obpwWI7RZmwSJzGFbN-QaUyy_lmgEaU7lVwxHUb?QVnDpSYGnTjhG0uDtyPTiR Scale = 1:30.1 Sheet FrontFull Sheathing1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 18 19 3x6 4x6 3x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 16-9-0 16-9-0 -1-0-0 1-0-0 8-4-8 8-4-8 16-9-0 8-4-8 17-9-0 1-0-0 0-9-03-6-80-9-04.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.14 0.11 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.01 0.00 (loc) 9 9 10 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 123 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-9-0. (lb) - Max Horz 17=16(LC 14) Max Grav All reactions 250 lb or less at joint(s) 13, 14, 12 except 17=262(LC 1), 10=262(LC 1), 15=307(LC 23), 11=307(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 5-4-8, Corner(3R) 5-4-8 to 11-4-8, Exterior(2N) 11-4-8 to 14-9-0, Corner(3E) 14-9-0 to 17-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss M01 Truss Type MONO TRUSS Qty 9 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535891 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:29:55 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-um1KAKmORYiLlv46V_?qXd1y?Cow?EOtvwmRlKyPTiQ Scale = 1:13.2 1 2 3 5 4 3x6 2x4 2x4 3-11-8 3-11-8 -1-0-0 1-0-0 3-11-8 3-11-8 0-9-02-0-131-9-50-3-82-0-134.00 12 Plate Offsets (X,Y)-- [4:0-2-0,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=35(LC 7) Max Uplift 5=-14(LC 6), 4=-4(LC 6) Max Grav 5=228(LC 1), 4=138(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 5 and 4 lb uplift at joint 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss M02 Truss Type MONO TRUSS Qty 1 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535892 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:29:55 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-um1KAKmORYiLlv46V_?qXd1tuClk?EttvwmRlKyPTiQ Scale = 1:18.5 1 2 3 5 4 8 9 6 7 3x6 2x4 2x4 5-11-8 5-11-8 -1-0-0 1-0-0 5-11-8 5-11-8 0-9-02-8-130-3-84.00 12 Plate Offsets (X,Y)-- [4:0-2-0,0-0-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.46 0.31 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.09 -0.11 0.00 (loc) 4-5 4-5 l/defl >737 >597 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=38(LC 6) Max Uplift 5=-9(LC 6), 4=-11(LC 6) Max Grav 5=304(LC 1), 4=221(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-254/89 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 2-10-4, Exterior(2E) 2-10-4 to 5-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 9 lb uplift at joint 5 and 11 lb uplift at joint 4. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss PB01 Truss Type GABLE Qty 26 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535893 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:29:56 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-MzbjNgn0BrqCM3fI3iX34ra97c7gkhd08aV?HmyPTiP Scale = 1:13.1 2 3 4 1 5 3x4 2x4 2x4 5-2-0 5-2-0 2-7-0 2-7-0 5-2-0 2-7-0 -0-0-41-8-71-8-110-1-00-1-88.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-2-0. (lb) - Max Horz 1=-17(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 2, 4 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss PBE01 Truss Type GABLE Qty 2 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535894 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:29:57 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-r995b0nfy9y3_DEVdP2Id27Kt0TvT7t9NEFYqCyPTiO Scale = 1:13.1 Sheet Front Full Sheathing 1 Ply 7/16OSB8 2 3 4 1 5 3x4 2x4 2x4 5-2-0 5-2-0 2-7-0 2-7-0 5-2-0 2-7-0 -0-0-41-8-71-8-110-1-00-1-88.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-2-0. (lb) - Max Horz 1=-17(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 2, 4 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss T01 Truss Type Common Qty 4 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535895 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:29:58 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-JLjToMoHjT4wcNphA7ZX9GfN3QezCOkJcu_6MfyPTiN Scale = 1:55.1 1 2 3 4 5 6 7 10 9 8 11 12 13 14 15 16 4x6 5x12 3x4 3x4 3x6 4x8 3x6 4x8 10-5-8 10-5-8 20-11-0 10-5-8 -1-0-0 1-0-0 5-4-8 5-4-8 10-5-8 5-1-0 15-6-8 5-1-0 20-11-0 5-4-8 21-11-0 1-0-0 1-2-09-0-21-2-09.00 12 Plate Offsets (X,Y)-- [8:Edge,0-1-8], [9:0-6-0,0-3-4], [10:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.53 0.85 0.79 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.22 -0.45 0.02 (loc) 8-9 8-9 8 l/defl >999 >549 n/a L/d 240 180 n/a PLATES MT20 Weight: 87 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-10,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=0-3-8, 8=0-3-8 Max Horz 10=-109(LC 8) Max Grav 10=894(LC 1), 8=894(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-321/28, 3-4=-750/0, 4-5=-750/0, 5-6=-321/28, 2-10=-358/19, 6-8=-358/19 BOT CHORD 9-10=0/660, 8-9=0/660 WEBS 4-9=0/532, 3-10=-652/0, 5-8=-652/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-5-8, Exterior(2R) 7-5-8 to 13-5-8, Interior(1) 13-5-8 to 18-11-0, Exterior(2E) 18-11-0 to 21-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss T02 Truss Type Common Qty 3 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535896 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:29:59 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-nXHr0ipvUmCnDXOtkq4miTCYpqzCxqNSqYkfu5yPTiM Scale = 1:55.1 1 2 3 4 5 6 9 8 7 10 11 12 13 14 15 4x6 3x6 5x12 3x4 3x4 3x6 4x8 4x8 10-5-8 10-5-8 20-11-0 10-5-8 -1-0-0 1-0-0 5-4-8 5-4-8 10-5-8 5-1-0 15-6-8 5-1-0 20-11-0 5-4-8 1-2-09-0-21-2-09.00 12 Plate Offsets (X,Y)-- [7:Edge,0-1-8], [8:0-6-0,0-3-4], [9:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.53 0.85 0.83 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.22 -0.45 0.02 (loc) 8-9 8-9 7 l/defl >999 >549 n/a L/d 240 180 n/a PLATES MT20 Weight: 86 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-9,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)9=0-3-8, 7=0-3-8 Max Horz 9=106(LC 7) Max Grav 9=896(LC 1), 7=823(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-321/28, 3-4=-753/0, 4-5=-754/0, 5-6=-295/13, 2-9=-358/19, 6-7=-265/4 BOT CHORD 8-9=0/663, 7-8=0/669 WEBS 4-8=0/534, 3-9=-655/0, 5-7=-684/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-5-8, Exterior(2R) 7-5-8 to 13-5-8, Interior(1) 13-5-8 to 17-9-4, Exterior(2E) 17-9-4 to 20-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss T03 Truss Type Piggyback Base Qty 11 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535897 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:01 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-jwPcQOq90OSVTqYGsF6EnuHpmdg0PoVlIsDmzzyPTiK Scale = 1:80.6 1 2 3 4 5 6 7 8 910 18 17 16 15 14 13 12 11 19 20 21 22 23 24 25 3x6 5x8 5x8 3x6 12x18 MT18HS 3x8 MT18HS 3x4 3x6 3x6 3x8 3x4 3x6 3x6 12x18 MT18HS 8-4-0 8-4-0 16-4-8 8-0-8 21-6-8 5-2-0 29-7-0 8-0-8 37-11-0 8-4-0 -1-0-0 1-0-0 8-4-0 8-4-0 16-4-8 8-0-8 21-6-8 5-2-0 29-7-0 8-0-8 37-11-0 8-4-0 38-11-0 1-0-0 1-1-012-0-01-1-012-0-08.00 12 Plate Offsets (X,Y)-- [3:0-1-12,0-1-8], [5:0-5-12,0-2-0], [6:0-5-12,0-2-0], [8:0-1-12,0-1-8], [11:Edge,0-10-2], [12:0-2-4,0-1-8], [17:0-2-4,0-1-8], [18:Edge,0-10-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.88 0.83 0.60 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.19 -0.35 0.07 (loc) 15-17 15-17 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 178 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-15,5-14,6-14,2-18,9-11: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-10-15 max.): 5-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-15, 5-14, 8-14 REACTIONS. (size)18=0-3-8, 11=0-3-8 Max Horz 18=141(LC 9) Max Grav 18=1742(LC 17), 11=1740(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2273/0, 3-5=-1752/0, 5-6=-1358/0, 6-8=-1749/0, 8-9=-2269/0, 2-18=-1614/0, 9-11=-1611/0 BOT CHORD 17-18=-83/531, 15-17=0/1877, 14-15=0/1392, 12-14=0/1796, 11-12=-9/430 WEBS 3-17=0/301, 3-15=-623/32, 5-15=0/640, 6-14=0/619, 8-14=-622/32, 8-12=0/301, 2-17=0/1401, 9-12=0/1398 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 12-1-9, Exterior(2R) 12-1-9 to 25-9-7, Interior(1) 25-9-7 to 35-11-0, Exterior(2E) 35-11-0 to 38-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) The Fabrication Tolerance at joint 2 = 0%, joint 9 = 0% 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss T04 Truss Type Piggyback Base Qty 15 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535898 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:02 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-B6y_ekrnnhbL4_6SPydTJ6qyy10J8FkuWWyJVQyPTiJ Scale = 1:77.3 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 18 19 20 21 22 23 24 3x6 5x8 5x8 3x8 12x18 MT18HS 3x8 MT18HS 3x4 3x6 3x6 3x8 3x4 3x8 3x8 MT18HS 6x6 3x6 8-4-0 8-4-0 16-4-8 8-0-8 21-6-8 5-2-0 29-5-4 7-10-12 37-7-8 8-2-4 -1-0-0 1-0-0 8-4-0 8-4-0 16-4-8 8-0-8 21-6-8 5-2-0 29-5-4 7-10-12 37-7-8 8-2-4 1-1-012-0-01-3-512-0-08.00 12 Plate Offsets (X,Y)-- [3:0-1-12,0-1-8], [5:0-5-12,0-2-0], [6:0-5-12,0-2-0], [7:0-1-12,0-1-8], [9:0-3-4,Edge], [11:0-2-8,0-1-8], [16:0-2-4,0-1-8], [17:Edge,0-10-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.98 0.82 0.60 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.19 -0.35 0.07 (loc) 14-16 14-16 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 176 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-14,5-13,6-13,2-17: 2x4 SPF No.2, 9-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-11-9 max.): 5-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-14, 5-13, 7-13 REACTIONS. (size)17=0-3-8, 10=Mechanical Max Horz 17=139(LC 7) Max Grav 17=1730(LC 17), 10=1665(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2254/0, 3-5=-1732/0, 5-6=-1335/0, 6-7=-1722/0, 7-9=-2187/0, 9-10=-1540/0, 2-17=-1602/0 BOT CHORD 16-17=-88/527, 14-16=0/1858, 13-14=0/1372, 11-13=0/1738 WEBS 3-16=0/302, 3-14=-624/32, 5-14=0/642, 6-13=0/613, 7-13=-583/37, 7-11=-3/261, 9-11=0/1518, 2-16=0/1386 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 12-1-9, Exterior(2R) 12-1-9 to 25-9-7, Interior(1) 25-9-7 to 34-5-12, Exterior(2E) 34-5-12 to 37-5-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) The Fabrication Tolerance at joint 2 = 0% 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Refer to girder(s) for truss to truss connections. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss T05 Truss Type Common Qty 1 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535899 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:03 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-fJWMr3sPY?jCi8hezg9isJND5RVftqH2lAit1syPTiI Scale = 1:35.0 1 2 3 4 5 6 7 10 9 8 4x6 3x4 3x4 3x8 2x4 2x4 4x6 4x6 5-11-8 5-11-8 11-11-0 5-11-8 -1-0-0 1-0-0 3-1-0 3-1-0 5-11-8 2-10-8 8-10-0 2-10-8 11-11-0 3-1-0 12-11-0 1-0-0 1-2-05-7-101-2-09.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [6:0-3-0,0-1-12], [8:0-1-12,0-1-8], [10:0-1-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.64 0.24 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.06 0.01 (loc) 9 9 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 46 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-10,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=0-3-8, 8=0-3-8 Max Horz 10=-72(LC 8) Max Grav 10=534(LC 1), 8=534(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-466/9, 3-4=-348/24, 4-5=-348/24, 5-6=-466/9, 2-10=-460/18, 6-8=-460/18 BOT CHORD 9-10=0/294, 8-9=0/289 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 2-11-8, Exterior(2R) 2-11-8 to 8-11-4, Interior(1) 8-11-4 to 9-11-0, Exterior(2E) 9-11-0 to 12-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss T06 Truss Type Common Qty 4 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535900 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:04 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:osuczORs1obpwWI7RZmwSJzGFbN-7V4k3Pt2JJr3KIGrXNgxPXvMKrmScHzB_qRQZIyPTiH Scale = 1:30.1 1 2 3 4 5 6 7 11 10 9 8 12 13 14 15 4x6 6x8 3x6 3x8 2x4 2x4 6x8 8-4-8 8-4-8 16-9-0 8-4-8 -1-0-0 1-0-0 4-3-8 4-3-8 8-4-8 4-1-0 12-5-8 4-1-0 16-9-0 4-3-8 17-9-0 1-0-0 0-9-03-6-80-9-04.00 12 Plate Offsets (X,Y)-- [8:Edge,0-5-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.74 0.52 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.21 0.03 (loc) 9-11 9-11 8 l/defl >999 >941 n/a L/d 240 180 n/a PLATES MT20 Weight: 53 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-11,6-8: 2x6 SP 2400F 2.0E BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-6 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)11=0-3-8, 8=0-3-8 Max Horz 11=16(LC 10) Max Grav 11=725(LC 1), 8=725(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1096/0, 3-4=-921/0, 4-5=-921/0, 5-6=-1096/0, 2-11=-634/51, 6-8=-634/51 BOT CHORD 9-11=0/969, 8-9=0/969 WEBS 4-9=0/333 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-4-8, Exterior(2R) 5-4-8 to 11-4-8, Interior(1) 11-4-8 to 14-9-0, Exterior(2E) 14-9-0 to 17-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss TG01 Truss Type COMMON GIRDER Qty 1 Ply 2 18 Estates at Towne Meadow Job Reference (optional) I48535901 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:07 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-Y4mthRvwcEDeBl?QCWDe09Xwr2ndpT3egng4AdyPTiE Scale = 1:77.6 1 2 3 4 5 6 7 11 10 9 8121314151617181920212223 24 25 26 27 4x8 3x4 3x4 3x4 5x12 4x8 3x4 3x4 3x4 8x16 6x18 MT18HS 8x16 5x12 3x6 5x12 5x12 3x6 5x12 8x16 7-6-8 7-6-8 14-10-8 7-4-0 22-2-8 7-4-0 29-9-0 7-6-8 7-6-8 7-6-8 14-10-8 7-4-0 22-2-8 7-4-0 29-9-0 7-6-8 1-2-012-3-141-2-09.00 12 Plate Offsets (X,Y)-- [3:0-3-8,0-2-4], [5:0-3-8,0-2-4], [8:0-8-0,0-2-8], [11:0-8-0,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.53 0.56 0.79 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.31 0.08 (loc) 9-11 9-11 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 525 lb FT = 20% GRIP 197/144 244/190 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x10 SP 2400F 2.0E WEBS 2x4 SPF No.2 *Except* 4-9: 2x4 SPF 2100F 1.8E SLIDER Left 2x6 SPF No.2 8-11-6, Right 2x6 SPF No.2 8-11-6 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-15 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-9, 3-9 REACTIONS. (size)1=0-3-8 (req. 0-5-9), 7=0-3-8 (req. 0-5-9) Max Horz 1=-128(LC 6) Max Grav 1=13440(LC 2), 7=13473(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-16207/0, 3-4=-11028/0, 4-5=-11028/0, 5-7=-16201/0 BOT CHORD 1-11=0/12476, 9-11=0/12476, 8-9=0/12471, 7-8=0/12471 WEBS 4-9=0/12749, 5-9=-4899/0, 5-8=0/6408, 3-9=-4906/0, 3-11=0/6416 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Bottom chords connected as follows: 2x10 - 2 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) WARNING: Required bearing size at joint(s) 1, 7 greater than input bearing size. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1626 lb down at 0-10-12, 1624 lb down at 2-10-12, 1624 lb down at 4-10-12, 1622 lb down at 6-10-12, 1609 lb down at 8-10-12, 1620 lb down at 10-10-12, 1624 lb down at 12-10-12, 1624 lb down at 14-10-12, 1624 lb down at 16-10-12, 1619 lb down at 18-10-12, 1609 lb down at 20-10-12, 1623 lb down at 22-10-12, 1624 lb down at 24-10-12, and 1624 lb down at 26-10-12, and 1626 lb down at 28-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Continued on page 2 October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss TG01 Truss Type COMMON GIRDER Qty 1 Ply 2 18 Estates at Towne Meadow Job Reference (optional) I48535901 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:07 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-Y4mthRvwcEDeBl?QCWDe09Xwr2ndpT3egng4AdyPTiE LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-7=-60, 1-7=-20 Concentrated Loads (lb) Vert: 9=-1472(F) 12=-1473(F) 13=-1472(F) 14=-1472(F) 15=-1472(F) 16=-1472(F) 18=-1472(F) 19=-1472(F) 20=-1472(F) 21=-1472(F) 23=-1472(F) 24=-1472(F) 25=-1472(F) 26=-1472(F) 27=-1474(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss V01 Truss Type GABLE Qty 1 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535902 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:08 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-0GKFunwYNXLVovacmDktZN4BxSD6Y3nnvRPdj3yPTiD Scale: 3/16"=1' 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 173x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 25-9-6 25-9-6 12-10-11 12-10-11 25-9-6 12-10-11 0-0-49-8-00-0-49.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.18 0.16 0.25 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 87 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.All bearings 25-9-6. (lb) - Max Horz 1=-102(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 12, 13, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=361(LC 20), 12=424(LC 17), 13=469(LC 17), 9=424(LC 18), 8=469(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-13=-273/62, 6-8=-273/62 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-4 to 3-5-4, Interior(1) 3-5-4 to 9-10-11, Exterior(2R) 9-10-11 to 15-10-11, Interior(1) 15-10-11 to 22-4-2, Exterior(2E) 22-4-2 to 25-4-2 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13, 9, 8. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss V02 Truss Type GABLE Qty 1 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535903 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:09 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-UTud67xA8rTMQ39oKwF66acMysZVHW3w859BFWyPTiC Scale = 1:54.9 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 22-2-11 22-2-11 11-1-6 11-1-6 22-2-11 11-1-6 0-0-48-4-00-0-49.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.17 0.15 0.24 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 72 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-12: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 22-2-11. (lb) - Max Horz 1=-88(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 11, 13, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=354(LC 20), 11=422(LC 17), 13=332(LC 17), 9=421(LC 18), 8=333(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-265/65, 5-9=-265/65 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-4 to 3-5-4, Interior(1) 3-5-4 to 8-1-6, Exterior(2R) 8-1-6 to 14-1-6, Interior(1) 14-1-6 to 18-9-7, Exterior(2E) 18-9-7 to 21-9-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11, 13, 9, 8. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss V03 Truss Type GABLE Qty 1 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535904 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:10 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-yfR?JTxou9bD2Dk_tenLeo9U6Ft60_n4MluknyyPTiB Scale = 1:46.4 1 2 3 4 5 9 8 7 6 10 11 3x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 18-8-1 18-8-1 9-4-0 9-4-0 18-8-1 9-4-0 0-0-47-0-00-0-49.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.27 0.31 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 52 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 18-8-1. (lb) - Max Horz 1=-74(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=312(LC 20), 9=529(LC 17), 6=529(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-329/72, 4-6=-329/72 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-9 to 3-4-9, Interior(1) 3-4-9 to 6-4-0, Exterior(2R) 6-4-0 to 12-4-0, Interior(1) 12-4-0 to 15-3-7, Exterior(2E) 15-3-7 to 18-3-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss V04 Truss Type GABLE Qty 1 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535905 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:11 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-Qr?OXpyRfSj4gNIBRLIaB?ifBfGGlSTDbPeIJOyPTiA Scale = 1:35.2 1 2 3 4 5 8 7 6 9 10 11 123x4 3x6 3x4 2x4 2x4 2x4 2x4 2x4 15-1-6 15-1-6 7-6-11 7-6-11 15-1-6 7-6-11 0-0-45-8-00-0-49.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.31 0.13 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-1-6. (lb) - Max Horz 1=-59(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=339(LC 17), 8=389(LC 17), 6=389(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-1 to 3-6-11, Interior(1) 3-6-11 to 4-6-11, Exterior(2R) 4-6-11 to 10-6-11, Interior(1) 10-6-11 to 11-6-11, Exterior(2E) 11-6-11 to 14-8-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss V05 Truss Type GABLE Qty 1 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535906 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:11 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-Qr?OXpyRfSj4gNIBRLIaB?ib8fDFlSpDbPeIJOyPTiA Scale = 1:27.2 1 2 3 4 5 6 3x8 5x6 3x8 2x4 11-6-11 11-6-11 5-9-6 5-9-6 11-6-11 5-9-6 0-0-44-4-00-0-49.00 12 Plate Offsets (X,Y)-- [1:0-5-13,Edge], [2:0-4-0,0-2-0], [3:0-2-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.57 0.32 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=11-6-11, 3=11-6-11, 4=11-6-11 Max Horz 1=-45(LC 6) Max Grav 1=208(LC 1), 3=208(LC 1), 4=441(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-1 to 3-5-1, Exterior(2R) 3-5-1 to 8-1-10, Exterior(2E) 8-1-10 to 11-1-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss V06 Truss Type GABLE Qty 1 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535907 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:12 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:Z1KeJe5MxNveIuL8LQgQDJzbeli-v2Zmk8z3QmrxHWtN?3ppjDEni3Z5UwxNq3NrsryPTi9 Scale = 1:20.9 1 2 3 4 5 6 2x4 3x4 2x4 2x4 8-0-1 8-0-1 4-0-0 4-0-0 8-0-1 4-0-0 0-0-43-0-00-0-49.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.45 0.22 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-0-1, 3=8-0-1, 4=8-0-1 Max Horz 1=-30(LC 8) Max Grav 1=163(LC 1), 3=163(LC 1), 4=264(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-3-12 to 3-3-12, Exterior(2R) 3-3-12 to 4-8-5, Exterior(2E) 4-8-5 to 7-8-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss V07 Truss Type Valley Qty 1 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535908 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:13 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:HcdmHTIRyaSkCNnibpDOb0y9Rva-NE78yU_hB4zovgSZZmK2GQn2rTu4DNrW2j7OOHyPTi8 Scale = 1:11.1 1 2 3 2x4 2x4 2x4 0-0-5 0-0-5 4-5-6 4-5-1 2-2-11 2-2-11 4-5-6 2-2-11 0-0-41-8-00-0-49.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.11 0.30 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-6 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-4-11, 3=4-4-11 Max Horz 1=-16(LC 8) Max Grav 1=153(LC 1), 3=153(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss V08 Truss Type VALLEY Qty 2 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535909 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:14 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-rQhW9q_JyN5eXq1m6UrHpeKCusHOyqVgHNsywjyPTi7 Scale = 1:35.6 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 7 6 10 9 8 4x6 3x4 3x4 3x4 3x4 4x6 3x4 2x4 3x4 3x4 2-11-0 2-11-0 -0-6-0 0-6-0 1-5-8 1-5-8 2-11-0 1-5-8 3-5-0 0-6-0 5-3-106-4-125-3-109.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4], [4:0-2-0,0-1-4], [6:0-2-0,0-2-0], [7:0-2-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.15 0.10 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 4 4 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 61 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 8 REACTIONS. (size)7=2-11-0, 6=2-11-0 Max Horz 7=-98(LC 8) Max Uplift 7=-74(LC 6), 6=-74(LC 7) Max Grav 7=208(LC 18), 6=200(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss V09 Truss Type VALLEY Qty 2 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535910 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:15 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-JcFuMA?xjhDV8_cygBMWLrsNCGc0hGSpW1cVS9yPTi6 Scale = 1:28.7 1 2 3 4 5 8 7 6 2x4 2x4 3x4 2x4 2x4 2x4 2-11-0 2-11-0 -0-6-0 0-6-0 1-5-8 1-5-8 2-11-0 1-5-8 3-5-0 0-6-0 3-11-105-0-123-11-109.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.18 0.14 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 4 4 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=2-11-0, 6=2-11-0, 7=2-11-0 Max Horz 8=-77(LC 8) Max Uplift 8=-47(LC 6), 6=-47(LC 7) Max Grav 8=126(LC 18), 6=126(LC 17), 7=104(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss V10 Truss Type VALLEY Qty 2 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535911 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:16 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-nppHaW0ZU?LMm8B8Evulu3PZZgzMQjDylhL3?cyPTi5 Scale = 1:21.8 1 2 3 4 5 8 7 6 2x4 2x4 3x4 2x4 2x4 2x4 2-11-0 2-11-0 -0-6-0 0-6-0 1-5-8 1-5-8 2-11-0 1-5-8 3-5-0 0-6-0 2-7-103-8-122-7-109.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.08 0.07 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 4 4 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=2-11-0, 6=2-11-0, 7=2-11-0 Max Horz 8=-56(LC 8) Max Uplift 8=-15(LC 6), 6=-15(LC 7) Max Grav 8=101(LC 18), 6=101(LC 17), 7=103(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss V11 Truss Type VALLEY Qty 2 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535912 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:17 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-F?Nfns1BFIUDOImLocP_QGyls4KE9Ac6zL5cX2yPTi4 Scale = 1:14.9 1 2 3 4 5 8 7 6 2x4 2x4 3x4 2x4 2x4 2x4 2-11-0 2-11-0 -0-6-0 0-6-0 1-5-8 1-5-8 2-11-0 1-5-8 3-5-0 0-6-0 1-3-102-4-121-3-109.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.04 0.03 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 4 4 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=2-11-0, 6=2-11-0, 7=2-11-0 Max Horz 8=-35(LC 8) Max Uplift 8=-5(LC 10), 6=-5(LC 11) Max Grav 8=95(LC 23), 6=95(LC 24), 7=101(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 27,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 18_ESTATES_AT_TOWNE_~W Truss V12 Truss Type Valley Qty 2 Ply 1 18 Estates at Towne Meadow Job Reference (optional) I48535913 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 26 17:30:17 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-F?Nfns1BFIUDOImLocP_QGyl14JC9Aq6zL5cX2yPTi4 Scale: 1.5"=1' 1 2 3 2x4 2x4 2x4 0-0-5 0-0-5 2-10-1 2-9-11 1-5-0 1-5-0 2-10-1 1-5-0 0-0-41-0-120-0-49.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.03 0.09 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-1 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-9-6, 3=2-9-6 Max Horz 1=9(LC 7) Max Grav 1=88(LC 1), 3=88(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). October 27,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths