HomeMy WebLinkAboutH-305 - ENLARGED HVAC PLANSTTT TT FCU-3 EF-1 EF-1 16/125"ø 7"ø 7"ø 5"ø 7"ø 7"ø 7"ø SG 6/6 50 6/6 SG50 SG 12/6 235 SG 12/6 200 SG 12/6 225 12/6 SG165 SG 12/6 50 1 1 2 4 1 1 1 5 1 2 4 3 7 8 9 11 12 6 G- 24/10 6ø 4ø 6ø 24/16 G975 16/12 FD G - 24/10 6 DBF-1 1 6ø EF-1 FCU-3 EF-1 16/127"ø 5"ø 7"ø 7"ø 7"ø 5"ø 7"ø EF-1 SG 12/6 245 SG 12/6 190 SG 12/6 220 SG 12/6 120 SG 6/6 50 6/6 SG50 12/6 SG50 11 7 8 9 1 1 1 1 1 1 2 12 2 2 5 4 3 4 6 4 G- 24/10 1 6ø 6ø6ø 6ø 24/16 G975 10 G- 24/10 6 FD 4ø DBF-1 FD 24/10 G565 SG 12/6 165 SG 12/6 200 SG 6/6 50 1 1 1 1 7 8 9 3 4 2 12/6 SG200 EF-1 7"ø 5"ø 7"ø 4ø 6ø DBF-1 FCU-1 12/10 7"ø FD G- 24/10 G - 24/10 6 6 6 5 FCU-1 EF-1 SG 12/6 200 SG 6/6 50 12/6 SG14012/101 1 1 1 2 2 3 4 9 8 7 24/10 G565 7"ø7"ø 7"ø 5"ø SG 12/6 175 DBF-1 6 6ø 4ø FD G- 24/10 G - 24/10 6 6 5 FCU-1 12/1024/10 G565 12/1012/6 SG180 12/6 SG180 6/6 SG50 12/6 SG155 EF-1 1 1 1 2 10 4 3 5 7 8 9 1 DBF-1 FD 11700201 No. STATE OFJOSEPHR.BO L Y ARDPROFES S ION A L E N G INEERLICENSE EXPIRES 07/31/22 DATE SIGNED 11/24/21 R E G I S TER E D I ND I A N A 19030 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032CONSTRUCTION DOCUMENTS750 Veterans Way11/24/21 BUILDING SHELL BID PHASE III H-305 ENLARGED HVAC PLANS 11/24/2111/24/21 RWEH 1/4" = 1'-0" Unit Type C1 Enlarged HVAC Plan1 1/4" = 1'-0" Unit Type C2 Enlarged HVAC Plan3 SHEET PLAN NOTES 1 FURNISH AND INSTALL CEILING RADIATION DAMPER AT ALL LOCATIONS WHERE GRILLES PENETRATE A FIRE RATED CEILING. 2 TERMINATE EXHAUST DUCT WITH WALL VENT. CUSTOM COLOR TO BE SELECTED BY ARCHITECT. BASIS OF DESIGN FOR VENT CAP IS DEFLECTO MODEL HSB4W. SEE ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS. 3 FURNISH AND INSTALL DRYER BOX PER MANUFACTURER'S INSTRUCTIONS. MOUNT BOTTOM OF DRYER BOX AT NOMINAL 6" ABOVE FINISHED FLOOR FOR STANDARD DRYERS AND COORDINATE INSTALLATION HEIGHT FOR STACKABLE DRYERS. SEAL AROUND BOX PERIMETER. INSTALL LABEL SHOWING EQUIVALENT LENGTH OF INSTALLED DRYER VENT (INCLUDING NUMBER OF ELBOWS) PER MECHANICAL CODE. 4 FURNISH AND INSTALL BATHROOM EXHAUST FAN EF-1 IN WALL. USE ONLY SMOOTH RADIUS ELBOWS (R/D = 1.5). MAINTAIN 4"ø DUCTWORK IN WALL THROUGH ELBOW. FLAIR OUT TO 6"ø DUCT ABOVE CEILING. 5 FURNISH AND INSTALL 7 DAY PROGRAMMABLE THERMOSTAT WITH THE TOP 48" ABOVE FINISHED FLOOR. 6 FURNISH AND INSTALL TRANSFER GRILLE 6" ABOVE TOP OF DOOR. SHEETMETAL TO BE INSTALLED THROUGH THE WALL. PAINT ANY STUDS THAT INTERSECT BLACK. 7 PROVIDE FLEXIBLE CONNECTION TO FCU DISCHARGE BEFORE CONNECTION TO SUPPLY DUCTWORK. FURNISH AND INSTALL FIRE DAMPER WHERE DUCT PENETRATES RATED CEILING PARTITION. 8 PROVIDE TRAPPED 3/4" CPVC CONDENSATE DRAIN LINE AND TERMINATE ABOVE HUB-DRAIN LOCATED IN MECHANICAL CLOSET. DO NO BLOCK FILTER ACCESS. 9 ROUTE REFRIGERANT LINES UP TO ABOVE CEILING AND OVER TO FURRED OUT WALL. ROUTE UP TO ROOF, THEN TO APPROPRIATE CONDENSING UNIT SERVING THIS APARTMENT. SEE ROOF LEVEL HVAC PLANS FOR CONDENSING UNIT LOCATIONS AND DESIGNATIONS. REFRIGERANT LINES SIZED PER MANUFACTURER'S RECOMMENDATIONS. 11 6" OUTDOOR AIR DUCT PENETRATES THROUGH FIRE RATED CEILING. PROVIDE FIRE DAMPER AT PENETRATION. TAP INTO SIDE OF RETURN DUCTWORK WITH DAMPER. BALANCE AIRFLOW TO 60 CFM. 12 TERMINATE OUTDOOR AIR DUCT WITH WALL VENT. CUSTOM COLOR TO BE SELECTED BY ARCHITECT. BASIS OF DESIGN FOR VENT CAP IS DEFLECTO MODEL HSB4W. SEE ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS. 1/4" = 1'-0" Unit Type D1 Enlarged HVAC Plan2 1/4" = 1'-0" Unit Type D2 Enlarged HVAC Plan4 1/4" = 1'-0" Unit Type D3 Enlarged HVAC Plan5