HomeMy WebLinkAboutEP107A - ROOF POWER PLAN - AREA AS SSH J
J
H.9
H.9
xJ
xJ
x17x17
xJ.5
xJ.5
x16.9x16.9
x18x18
x18.1x18.1
x19x19
x20x20
x21x21
x21.1x21.1
xJ.1
xJ.1
xJ.2
xJ.2
xJ.3
xJ.3
x21.4x21.4
x21.5x21.5
x21.9x21.9
x22x22
xH.5
xH.5
xH
xH
xG.5
xG.5
xG
xG
xF.9
xF.9
20.7 20.7
19.7 19.7
19.4 19.4
F.4
F.4 F.8
F.8 G.1
G.1
G.8
G.8
G.9
G.9
H.3
H.3
H.4
H.4 H.6
H.6 XJ.4
XJ.4
20.5 20.5
19.5 19.5
F.10
F.10
H.2
H.2
21.2 21.2
H.9
H.9
xJ
xJ
x17x17
xJ.5
xJ.5
x16.9x16.9
x18x18
x18.1x18.1
x19x19
x20x20
x21x21
x21.1x21.1
xJ.1
xJ.1
xJ.2
xJ.2
xJ.3
xJ.3
x21.4x21.4
x21.5x21.5
x21.9x21.9
x22x22
xH.5
xH.5
xH
xH
xG.5
xG.5
xG
xG
xF.9
xF.9
20.7 20.7
19.7 19.7
19.4 19.4
F.4
F.4 F.8
F.8 G.1
G.1
G.8
G.8
G.9
G.9
H.3
H.3
H.4
H.4 H.6
H.6 XJ.4
XJ.4
20.5 20.5
19.5 19.5
F.10
F.10
H.2
H.2
21.2 21.2
H1- 38
H1- 37
H1- 37
H1-8
H1-27
CU-2-407
CU-2-307
CU-2-507
CU-2-412
CU-2-312
CU-2-512
CU-1-410 CU-1-510
CU-1-310
CU-1-408
CU-1-308
CU-1-508
CU-1-303
CU-1-403 CU-1-503
CU-2-406
CU-2-306
CU-2-506
CU-2-401
CU-2-301
CU-2-501
CU-1-402
CU-1-302
CU-1-502
CU-1-500CU-1-400
CU-1-300
CU-1-404
CU-1-304
CU-1-504
CU-2-405
CU-2-305
CU-2-505
RTU-1
HDP-B-1
1
TYPICAL ALL ROOFTOP
CONDENSING UNITS
COORESPONDS TO UNIT TYPE 'A5'
-RE:DETAIL 2/E-301
H1-37
H1-37
H1-37
H1-38
H1-38
H1-38
H1-38
EF-2
RTU-3
HDP-B- 3
H2 - 17
'EMR'
RTU-2
A. SEE SHEET E-001 FOR SYMBOLS AND ABBREVIATIONS.
B. SEE SHEET E-604 FOR KITCHEN EQUIPMENT SCHEDULE.
C. SEE SHEET E-604 FOR MECHANICAL EQUIPMENT POWER SCHEDULE.
D. SEE SHEETS E-601 THROUGH E-603 FOR PANEL SCHEDULES.
E. SEE SHEETS E-501, E-502 AND E-503 FOR ELECTRICAL DETAILS.
F. WIRING SYSTEM SHALL BE CONDUIT AND CONDUCTOR UNLESS NOTED
OTHERWISE. USE SOLID CONDUCTOR FOR SIZE #10 AWG AND SMALLER.
USE STRANDED CONDUCTOR FOR LARGER SIZES.
G. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE OF A COLOR TO
MATCH THE AREA COLOR SCHEME AS DIRECTED BY THE INTERIOR
DESIGNER.
H. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES
AND ORDINANCES PERTAINING TO THE WORK IN THIS PROJECT.
I. EXPOSED CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO
BUILDING LINES.
J. REFER TO ARCHITECTURAL DRAWINGS FOR DESIGNATION AND LISTING OF
FIRE RATED ASSEMBLIES. COORDINATE ALL DESIGN EFFORTS WITH FIRE
RESISTANCE OF MATERIALS AND CONSTRUCTION.
K. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHER PROOF AND
RAIN TIGHT.
L. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL
INTERCONNECT WIRING FOR MECHANICAL AND PLUMBING EQUIPMENT
FURNISHED BY OTHERS.
GENERAL SHEET NOTES
19030
Project:
Developer:
Sheet Number:
Engineer:
By:
Sheet Title:
CDG Number:
Last Revision Date:
Set Issue Date
Drawn By Checked By
Sheet Issue DateWREN BUILDINGCarmel, IN 46032CONSTRUCTION
DOCUMENTS750 Veterans WayKEYPLAN
B
A
NOT FOR
CONSTRUCTION
EP107A
ROOF POWER PLAN -
AREA A
11/24/2111/24/21
1/8" = 1'-0"
ROOF POWER PLAN - AREA A1
N
0 16'8'4'
SHEET PLAN NOTES
1 COORDINATE WITH ENLARGED UNIT PLANS AS WELL AS ARCHITECTURAL
PLANS TO POWER CONDENSING UNITS FROM THEIR COORESPONDING
APARTMENT PANELS.11/24/2111/24/21 BUILDING SHELL
BID PHASE III