HomeMy WebLinkAboutEP107A - ROOF POWER PLAN - AREA AS SSH J J H.9 H.9 xJ xJ x17x17 xJ.5 xJ.5 x16.9x16.9 x18x18 x18.1x18.1 x19x19 x20x20 x21x21 x21.1x21.1 xJ.1 xJ.1 xJ.2 xJ.2 xJ.3 xJ.3 x21.4x21.4 x21.5x21.5 x21.9x21.9 x22x22 xH.5 xH.5 xH xH xG.5 xG.5 xG xG xF.9 xF.9 20.7 20.7 19.7 19.7 19.4 19.4 F.4 F.4 F.8 F.8 G.1 G.1 G.8 G.8 G.9 G.9 H.3 H.3 H.4 H.4 H.6 H.6 XJ.4 XJ.4 20.5 20.5 19.5 19.5 F.10 F.10 H.2 H.2 21.2 21.2 H.9 H.9 xJ xJ x17x17 xJ.5 xJ.5 x16.9x16.9 x18x18 x18.1x18.1 x19x19 x20x20 x21x21 x21.1x21.1 xJ.1 xJ.1 xJ.2 xJ.2 xJ.3 xJ.3 x21.4x21.4 x21.5x21.5 x21.9x21.9 x22x22 xH.5 xH.5 xH xH xG.5 xG.5 xG xG xF.9 xF.9 20.7 20.7 19.7 19.7 19.4 19.4 F.4 F.4 F.8 F.8 G.1 G.1 G.8 G.8 G.9 G.9 H.3 H.3 H.4 H.4 H.6 H.6 XJ.4 XJ.4 20.5 20.5 19.5 19.5 F.10 F.10 H.2 H.2 21.2 21.2 H1- 38 H1- 37 H1- 37 H1-8 H1-27 CU-2-407 CU-2-307 CU-2-507 CU-2-412 CU-2-312 CU-2-512 CU-1-410 CU-1-510 CU-1-310 CU-1-408 CU-1-308 CU-1-508 CU-1-303 CU-1-403 CU-1-503 CU-2-406 CU-2-306 CU-2-506 CU-2-401 CU-2-301 CU-2-501 CU-1-402 CU-1-302 CU-1-502 CU-1-500CU-1-400 CU-1-300 CU-1-404 CU-1-304 CU-1-504 CU-2-405 CU-2-305 CU-2-505 RTU-1 HDP-B-1 1 TYPICAL ALL ROOFTOP CONDENSING UNITS COORESPONDS TO UNIT TYPE 'A5' -RE:DETAIL 2/E-301 H1-37 H1-37 H1-37 H1-38 H1-38 H1-38 H1-38 EF-2 RTU-3 HDP-B- 3 H2 - 17 'EMR' RTU-2 A. SEE SHEET E-001 FOR SYMBOLS AND ABBREVIATIONS. B. SEE SHEET E-604 FOR KITCHEN EQUIPMENT SCHEDULE. C. SEE SHEET E-604 FOR MECHANICAL EQUIPMENT POWER SCHEDULE. D. SEE SHEETS E-601 THROUGH E-603 FOR PANEL SCHEDULES. E. SEE SHEETS E-501, E-502 AND E-503 FOR ELECTRICAL DETAILS. F. WIRING SYSTEM SHALL BE CONDUIT AND CONDUCTOR UNLESS NOTED OTHERWISE. USE SOLID CONDUCTOR FOR SIZE #10 AWG AND SMALLER. USE STRANDED CONDUCTOR FOR LARGER SIZES. G. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE OF A COLOR TO MATCH THE AREA COLOR SCHEME AS DIRECTED BY THE INTERIOR DESIGNER. H. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES AND ORDINANCES PERTAINING TO THE WORK IN THIS PROJECT. I. EXPOSED CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO BUILDING LINES. J. REFER TO ARCHITECTURAL DRAWINGS FOR DESIGNATION AND LISTING OF FIRE RATED ASSEMBLIES. COORDINATE ALL DESIGN EFFORTS WITH FIRE RESISTANCE OF MATERIALS AND CONSTRUCTION. K. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHER PROOF AND RAIN TIGHT. L. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL INTERCONNECT WIRING FOR MECHANICAL AND PLUMBING EQUIPMENT FURNISHED BY OTHERS. GENERAL SHEET NOTES 19030 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWREN BUILDINGCarmel, IN 46032CONSTRUCTION DOCUMENTS750 Veterans WayKEYPLAN B A NOT FOR CONSTRUCTION EP107A ROOF POWER PLAN - AREA A 11/24/2111/24/21 1/8" = 1'-0" ROOF POWER PLAN - AREA A1 N 0 16'8'4' SHEET PLAN NOTES 1 COORDINATE WITH ENLARGED UNIT PLANS AS WELL AS ARCHITECTURAL PLANS TO POWER CONDENSING UNITS FROM THEIR COORESPONDING APARTMENT PANELS.11/24/2111/24/21 BUILDING SHELL BID PHASE III