HomeMy WebLinkAboutH-106B - 6TH FLOOR HVAC PLAN - AREA BEWH-1
SEE 3/ H-304 FOR
ENLARGED PLAN
SEE 5/ H-305 FOR
ENLARGED PLAN
SEE 4/ H-304 FOR
ENLARGED PLAN
SEE 1/ H-306 FOR
ENLARGED PLAN
SEE 2/ H-306 FOR
ENLARGED PLAN
SEE 3/ H-306 FOR
ENLARGED PLAN
CU-1-313
CU-1-413
CU-1-513
CU-1-511
CU-1-411
CU-1-311
CU-1-314
CU-1-414
CU-1-514
CU-1-316
CU-1-416
CU-1-516
CU-1-318
CU-1-418
CU-1-518
G 16/16
600
FD
12/12
FD
FD
FD
8ø8ø8ø8"ø
8"ø
8"ø
FD
F 14/6
200
F 14/6
200
1
2
3
F 14/6
200
4
4
4
5
11700201
No.
STATE OFJOSEPHR.BO
L
Y
ARDPROFES
S ION A L E N G INEERLICENSE EXPIRES 07/31/22
DATE SIGNED 11/24/21
R E G I S TER
E
D
I
ND I A N A
19030
Project:
Developer:
Sheet Number:
Engineer:
By:
Sheet Title:
CDG Number:
Last Revision Date:
Set Issue Date
Drawn By Checked By
Sheet Issue DateWREN BUILDINGCarmel, IN 46032CONSTRUCTION
DOCUMENTS750 Veterans Way11/24/21 BUILDING SHELL BID
PHASE III
H-106B
6TH FLOOR HVAC
PLAN - AREA B
11/24/2111/24/21
RWEH
0 16'8'4'
N
1/8" = 1'-0"
6TH FLOOR HVAC PLAN - AREA B1
SHEET PLAN NOTES
1 FUTURE MAKEUP AIR UNIT FOR KITCHEN APPLICATION. OVERALL WEIGHT
3500 LBS.
2 FUTURE 3-TON ROOFTOP UNIT FOR POSSIBLE TENANT FITOUT. OVERALL
WEIGHT 925 LBS.
3 FUTURE EXHAUST FAN FOR KITCHEN APPLICATION. OVERALL WEIGHT 425
LBS.
4 FURNISH AND INSTALL CEILING RADIATION DAMPER AT ALL LOCATIONS
WHERE GRILLES PENETRATE A FIRE RATED CEILING.
5 FURNISH AND INSTALL ROOF CURB AND CAP EQUAL TO GREENHECK GPIP OR
ENGINEER APPROVED EQUAL. ROOF CURB AND CAP ARE TO BE INSTALLED
OVER FUTURE MECHANICAL SHAFT OPENING. FIELD VERIFY EXACT SHAFT
OPENING. SIZE ROOF CAP ACCORDINGLY.